In Vivo Dark-Field Radiography for Early Diagnosis and Staging of Pulmonary Emphysema
Authors:
- Katharina HellbachKHKatharina Hellbach
- Andre YaroshenkoAYAndre Yaroshenko
- Felix G. MeinelFMFelix G. Meinel
- Ali Ö. YildirimAYAli Ö. Yildirim
- Thomas M. ConlonTCThomas M. Conlon
- Martin BechMBMartin Bech
- Mark MuellerMMMark Mueller
- Astrid VelroyenAVAstrid Velroyen
- Mike NotohamiprodjoMNMike Notohamiprodjo
- Fabian BambergFBFabian Bamberg
- Sigrid AuweterSASigrid Auweter
- Maximilian ReiserMRMaximilian Reiser
- 1 July 2015
- journal article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 50 (7) , 430-435
Abstract
The aim of this study was to evaluate the suitability of in vivo x-ray dark-field radiography for early-stage diagnosis of pulmonary emphysema in mice. Furthermore, we aimed to analyze how the dark-field signal correlates with morphological changes of lung architecture at distinct stages of emphysema. Female 8- to 10-week-old C57Bl/6N mice were used throughout all experiments. Pulmonary emphysema was induced by orotracheal injection of porcine pancreatic elastase (80-U/kg body weight) (n = 30). Control mice (n = 11) received orotracheal injection of phosphate-buffered saline. To monitor the temporal patterns of emphysema development over time, the mice were imaged 7, 14, or 21 days after the application of elastase or phosphate-buffered saline. X-ray transmission and dark-field images were acquired with a prototype grating-based small-animal scanner. In vivo pulmonary function tests were performed before killing the animals. In addition, lungs were obtained for detailed histopathological analysis, including mean cord length (MCL) quantification as a parameter for the assessment of emphysema. Three blinded readers, all of them experienced radiologists and familiar with dark-field imaging, were asked to grade the severity of emphysema for both dark-field and transmission images. Histopathology and MCL quantification confirmed the introduction of different stages of emphysema, which could be clearly visualized and differentiated on the dark-field radiograms, whereas early stages were not detected on transmission images. The correlation between MCL and dark-field signal intensities (r = 0.85) was significantly higher than the correlation between MCL and transmission signal intensities (r = 0.37). The readers' visual ratings for dark-field images correlated significantly better with MCL (r = 0.85) than visual ratings for transmission images (r = 0.36). Interreader agreement and the diagnostic accuracy of both quantitative and visual assessment were significantly higher for dark-field imaging than those for conventional transmission images. X-ray dark-field radiography can reliably visualize different stages of emphysema in vivo and demonstrates significantly higher diagnostic accuracy for early stages of emphysema than conventional attenuation-based radiography.Keywords
This publication has 29 references indexed in Scilit:
- Cartilage and Soft Tissue Imaging Using X-raysInvestigative Radiology, 2014
- Phase-Contrast CT: Qualitative and Quantitative Evaluation of Atherosclerotic Carotid Artery PlaqueRadiology, 2014
- A Study on Mastectomy Samples to Evaluate Breast Imaging Quality and Potential Clinical Relevance of Differential Phase Contrast MammographyInvestigative Radiology, 2014
- In-vivo dark-field and phase-contrast x-ray imagingScientific Reports, 2013
- Pulmonary Emphysema Diagnosis with a Preclinical Small-Animal X-ray Dark-Field Scatter-Contrast ScannerRadiology, 2013
- Comparison of Contrast-to-Noise Ratios of Transmission and Dark-Field Signal in Grating-Based X-ray Imaging for Healthy Murine Lung TissueZeitschrift für Medizinische Physik, 2013
- Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light sourceProceedings of the National Academy of Sciences, 2012
- Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometer and a rotating anode x-ray tube: theory and experimentsOptics Express, 2010
- Hard-X-ray dark-field imaging using a grating interferometerNature Materials, 2008
- Demonstration of X-Ray Talbot InterferometryJapanese Journal of Applied Physics, 2003