Permissible performance limits of regression analyses in method comparisons
Authors:
- Rainer HaeckelRHRainer Haeckel
- Werner WosniokWWWerner Wosniok
- Nadera Al ShareefNSNadera Al Shareef
- 1 January 2011
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 49 (11) , 1805-16
Abstract
Method comparisons are indispensable tools for the extensive validation of analytic procedures. Laboratories often only want to know whether an established procedure (x-method) can be replaced by another one (y-method) without interfering with diagnostic purposes. Then split patients' samples are analyzed more or less simultaneously with both procedures designed to measure the same quantity. The measured values are usually presented graphically as a scatter or difference plots. The two methods are considered to be equivalent (comparable) if the data pairs scatter around the line of equality (x=y line) within permissible equivalence lines. It is proposed to derive these limits of permissible imprecision limits which are based on false-positive error rates. If all data pairs are within the limits, both methods lead to comparable false error rates. If one or more data pairs are outside the permissible equivalence limits, the x-method cannot simply be replaced by the y-method and further studies are required. The discordance may be caused either by aberrant values (outliers), non-linearity, bias or a higher variation of e.g., the y-values. The spread around the line of best fit can detect possible interferences if more than 1% of the data pairs are outside permissible spread lines in a scatter plot. Because bias between methods and imprecision can be inter-related, both require specific examinations for their identification.Keywords
This publication has 10 references indexed in Scilit:
- A new concept to derive permissible limits for analytical imprecision and bias considering diagnostic requirements and technical state-of-the-artClinical Chemistry and Laboratory Medicine (CCLM), 2011
- A new statistical method for evaluating long-term analytical performance of laboratories applied to an external quality assessment scheme for flow cytometryClinical Chemistry and Laboratory Medicine (CCLM), 2010
- Proposed classification of various limit values (guide values) used in assisting the interpretation of quantitative laboratory test resultsClinical Chemistry and Laboratory Medicine (CCLM), 2009
- Local regression: a new approach for measurement system comparison analysisClinical Chemistry and Laboratory Medicine (CCLM), 2008
- Comparison of Several Point-of-Care Testing (POCT) Glucometers with an Established Laboratory Procedure for the Diagnosis of Type 2 Diabetes Using the Discordance Rate. A New Statistical ApproachClinical Chemistry and Laboratory Medicine (CCLM), 2003
- Validity of linear regression in method comparison studies: is it limited by the statistical model or the quality of the analytical input data?Clinical Chemistry, 1998
- Comparing Two Methods of Clinical Measurement: A Personal HistoryInternational Journal of Epidemiology, 1995
- Evaluation of regression procedures for methods comparison studiesClinical Chemistry, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Use and Interpretation of Common Statistical Tests in Method-Comparison StudiesClinical Chemistry, 1973