Resonance Analysis and Coordinated Active Damping of Multiparallel Grid-Connected Converters Under Filter-Inductance Attenuation and Grid-Strength Variation
Open Access
Abstract
Parallel converter operation enables flexible capacity expansion of energy-storage power conversion systems. However, parallel converter interactions, filter-inductor saturation, and grid-strength variations increase the risk of resonance instability. The measured current-inductance characteristic is incorporated into an operating-point-dependent closed-loop Norton model. The grid current of an individual converter is decomposed into self-reference, parallel converter coupling, and grid-voltage-disturbance responses. It reveals that converter-side inductance attenuation shifts the internal and parallel resonances to higher frequencies and increases resonance-instability risk, whereas converter number and grid impedance primarily reshape the parallel resonance. A coordinated active-damping method is then developed: PCC voltage feedforward weakens common-network interaction, and capacitor-voltage feedback increases local LCL-filter damping. Simulation and experimental results validate the feasibility and effectiveness of the proposed control method. Experiments with two parallel converters validated the proposed control method. Stable transient current responses were achieved during a simultaneous current-reference step from 50 to 120 A, while the grid-current THD and power-sharing deviation remained below 3% and 5%, respectively.Keywords
Funding Information
- National Natural Science Foundation of China (U23A20653)
This publication has 26 references indexed in Scilit:
- Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection ChallengesIEEE Open Journal of the Industrial Electronics Society, 2024
- Distributed Coordinated Control for Stabilization of Multi-Inverter Power PlantIEEE Transactions on Industrial Electronics, 2023
- Modeling and Resonance Damping for the CM Loop of the MLCL-Filtered Grid-Connected Inverter With Variable Inductors Under the Weak Grid ConditionIEEE Journal of Emerging and Selected Topics in Power Electronics, 2021
- Highly Accurate Derivatives for LCL-Filtered Grid Converter With Capacitor Voltage Active DampingIEEE Transactions on Power Electronics, 2015
- Overview of current development in electrical energy storage technologies and the application potential in power system operationApplied Energy, 2015
- LCL-Filter Design for Robust Active Damping in Grid-Connected ConvertersIEEE Transactions on Industrial Informatics, 2014
- Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor–Current-Feedback Active-DampingIEEE Transactions on Power Electronics, 2014
- Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected InverterIEEE Transactions on Power Electronics, 2013
- Investigation and Active Damping of Multiple Resonances in a Parallel-Inverter-Based MicrogridIEEE Transactions on Power Electronics, 2012
- Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV PlantsIEEE Transactions on Power Electronics, 2010