Xinchun Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xinchun Feng has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Chushan Li
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications - Huan Yang
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications - Tianlun Xia
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications - Wuhua Li
Zhejiang University
2 shared publications - Xiangning He
Zhejiang University
2 shared publications Chao Wang
Inner Mongolia Power (Group) Company Ltd. Hohhot, China
1 shared publication
Latest Publications
- Open Access
Resonance Analysis and Coordinated Active Damping of Multiparallel Grid-Connected Converters Under Filter-Inductance Attenuation and Grid-Strength Variation
Parallel converter operation enables flexible capacity expansion of energy-storage power conversion systems. However, parallel converter interactions, filter-inductor saturation, and grid-strength variations increase the risk of resonance instability. The measured current-inductance characteristic is incorporated into an operating-point-dependent closed-loop Norton model. The grid current of an individual converter is decomposed into self-reference, parallel converter coupling, and grid-voltage-disturbance responses. It reveals that converter-side inductance attenuation shifts the internal and parallel resonances to higher frequencies and increases resonance-instability risk, whereas converter number and grid impedance primarily reshape the parallel resonance. A coordinated active-damping method is then developed: PCC voltage feedforward weakens common-network interaction, and capacitor-voltage feedback increases local LCL-filter damping. Simulation and experimental results validate the feasibility and effectiveness of the proposed control method. Experiments with two parallel converters validated the proposed control method. Stable transient current responses were achieved during a simultaneous current-reference step from 50 to 120 A, while the grid-current THD and power-sharing deviation remained below 3% and 5%, respectively.
Open AccessResonance Analysis and Coordinated Active Damping of Multiparallel Grid-Connected Converters Under Filter-Inductance Attenuation and Grid-Strength Variation
Parallel converter operation enables flexible capacity expansion of energy-storage power conversion systems. However, parallel converter interactions, filter-inductor saturation, and grid-strength variations increase the risk of resonance instability. The measured current-inductance characteristic is incorporated into an operating-point-dependent closed-loop Norton model. The grid current of an individual converter is decomposed into self-reference, parallel converter coupling, and grid-voltage-disturbance responses. It reveals that converter-side inductance attenuation shifts the internal and parallel resonances to higher frequencies and increases resonance-instability risk, whereas converter number and grid impedance primarily reshape the parallel resonance. A coordinated active-damping method is then developed: PCC voltage feedforward weakens common-network interaction, and capacitor-voltage feedback increases local LCL-filter damping. Simulation and experimental results validate the feasibility and effectiveness of the proposed control method. Experiments with two parallel converters validated the proposed control method. Stable transient current responses were achieved during a simultaneous current-reference step from 50 to 120 A, while the grid-current THD and power-sharing deviation remained below 3% and 5%, respectively.
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Fundamental Frequency Modulation with Dead-Time Compensation for Suppressing Surge Voltage in Modular Multilevel Resonant DC-DC Converters
Modular multilevel resonant dc-dc converters (MMRDCs) are becoming promising candidates in medium-voltage dc (MVDC) power distribution systems, owing to their outstanding features, including high scalability and control flexibility. The fundamental-frequency quasi-square-wave (QSW) modulation is a widely used technique for MMRDC. However, in practical drive implementation, the dead time in submodule (SM) devices could introduce a delay in the arm output voltage relative to the ideal modulation signal, leading to a mismatch between the upper arm and lower arm output voltages. This mismatch can cause surge voltages and current distortion in the modular multilevel converter (MMC) arms, jeopardizing the safe and stable operation of the converter. This paper presents a detailed analysis of the influence of dead time on modulation under various operating conditions and proposes a dead-time compensation method to achieve ideal QSW arm voltages. The proposed modulation reduces undesired voltage and current stress and mitigates disturbances caused by high dv/dt. Finally, validation is provided through both simulation and experimental results from a 10 kV MMRDC prototype.
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Fundamental Frequency Modulation with Dead-Time Compensation for Suppressing Surge Voltage in Modular Multilevel Resonant DC-DC Converters
Modular multilevel resonant dc-dc converters (MMRDCs) are becoming promising candidates in medium-voltage dc (MVDC) power distribution systems, owing to their outstanding features, including high scalability and control flexibility. The fundamental-frequency quasi-square-wave (QSW) modulation is a widely used technique for MMRDC. However, in practical drive implementation, the dead time in submodule (SM) devices could introduce a delay in the arm output voltage relative to the ideal modulation signal, leading to a mismatch between the upper arm and lower arm output voltages. This mismatch can cause surge voltages and current distortion in the modular multilevel converter (MMC) arms, jeopardizing the safe and stable operation of the converter. This paper presents a detailed analysis of the influence of dead time on modulation under various operating conditions and proposes a dead-time compensation method to achieve ideal QSW arm voltages. The proposed modulation reduces undesired voltage and current stress and mitigates disturbances caused by high dv/dt. Finally, validation is provided through both simulation and experimental results from a 10 kV MMRDC prototype.
- Open Access
A Si and SiC Hybrid Arms ANPC Converter Achieving Comprehensive Optimization of Power Quality, Efficiency, and Cost
Wide bandgap (WBG) power semiconductors such as silicon carbide (SiC) can significantly improve the performance of multilevel converters. However, there are three challenges for large-scale application: high cost, limited power ratings, and reliability issues. In this paper, we propose a Si and SiC hybrid arms active neutral-point-clamped (ANPC) converter, using smaller current rating SiC devices compared to other Si devices in this topology. By employing the hybrid-frequency modulation scheme, the Si devices switch at fundamental frequency (FF) or low frequency (LF), while the SiC devices switch at high frequency (HF). The equivalent circuit of the proposed converter is derived to analyze the principle of LF current ripple compensation. The closed-loop cooperative current control strategy is proposed to realize unequal current sharing in two arms and complete LF current ripple compensation. The Si arm processes major power, while the SiC arm compensates the LF current ripple generated by the Si arm and processes minor power. The proposed topology and control strategy are validated by simulation and experimental results. Compared with the existing typical topologies, the comprehensive optimization of power quality, efficiency, and cost is realized.
Open AccessA Si and SiC Hybrid Arms ANPC Converter Achieving Comprehensive Optimization of Power Quality, Efficiency, and Cost
Wide bandgap (WBG) power semiconductors such as silicon carbide (SiC) can significantly improve the performance of multilevel converters. However, there are three challenges for large-scale application: high cost, limited power ratings, and reliability issues. In this paper, we propose a Si and SiC hybrid arms active neutral-point-clamped (ANPC) converter, using smaller current rating SiC devices compared to other Si devices in this topology. By employing the hybrid-frequency modulation scheme, the Si devices switch at fundamental frequency (FF) or low frequency (LF), while the SiC devices switch at high frequency (HF). The equivalent circuit of the proposed converter is derived to analyze the principle of LF current ripple compensation. The closed-loop cooperative current control strategy is proposed to realize unequal current sharing in two arms and complete LF current ripple compensation. The Si arm processes major power, while the SiC arm compensates the LF current ripple generated by the Si arm and processes minor power. The proposed topology and control strategy are validated by simulation and experimental results. Compared with the existing typical topologies, the comprehensive optimization of power quality, efficiency, and cost is realized.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (3) , 3046-3058
A Hybrid Three-Level Hybrid Switch (Hybrid2) Active Neutral-Point-Clamped Converter With Optimal Switching Strategy
Multilevel converter topologies can adapt to the development trend of higher-voltage-standard and higher-power-rating in aviation power systems. To accomplish high efficiency and great power density, the wide bandgap (WBG) device such as silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) is employed. Nevertheless, the significant overall expense of all-SiC-based multilevel converters renders them uneconomical. In this paper, a hybrid 2 active neutral-point-clamped (ANPC) converter is proposed. It comprises only two Si/SiC hybrid switches, the rest four active switches are silicon (Si) insulate-gate bipolar transistors (IGBT). The hybrid frequency modulation scheme is designed to transfer almost all the switching tasks to HySs. Furthermore, by experimental test and theoretical derivation, the switching characteristics of the Si/SiC hybrid switch (HyS) are analyzed in depth. Based on these, an optimal switching strategy for the HyS is proposed to reduce power losses, improve power handling capability and ensure device security. A hybrid 2 ANPC converter experimental platform is constructed and tested. Consequently, the proposed converter attains cost-effectiveness, high efficiency, and exceptional reliability, making it particularly advantageous for high-power inverters and rectifiers in the modern aviation industry.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (3) , 3046-3058
A Hybrid Three-Level Hybrid Switch (Hybrid2) Active Neutral-Point-Clamped Converter With Optimal Switching Strategy
Multilevel converter topologies can adapt to the development trend of higher-voltage-standard and higher-power-rating in aviation power systems. To accomplish high efficiency and great power density, the wide bandgap (WBG) device such as silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) is employed. Nevertheless, the significant overall expense of all-SiC-based multilevel converters renders them uneconomical. In this paper, a hybrid 2 active neutral-point-clamped (ANPC) converter is proposed. It comprises only two Si/SiC hybrid switches, the rest four active switches are silicon (Si) insulate-gate bipolar transistors (IGBT). The hybrid frequency modulation scheme is designed to transfer almost all the switching tasks to HySs. Furthermore, by experimental test and theoretical derivation, the switching characteristics of the Si/SiC hybrid switch (HyS) are analyzed in depth. Based on these, an optimal switching strategy for the HyS is proposed to reduce power losses, improve power handling capability and ensure device security. A hybrid 2 ANPC converter experimental platform is constructed and tested. Consequently, the proposed converter attains cost-effectiveness, high efficiency, and exceptional reliability, making it particularly advantageous for high-power inverters and rectifiers in the modern aviation industry.