Autocorrelation Analysis Combined with a Wavelet Transform Method to Detect and Remove Cosmic Rays in a Single Raman Spectrum
- 1 August 2015
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 69 (8) , 984-992
Abstract
Cosmic rays (CRs) occasionally affect charge-coupled device (CCD) detectors, introducing large spikes with very narrow bandwidth in the spectrum. These CR features can distort the chemical information expressed by the spectra. Consequently, we propose here an algorithm to identify and remove significant spikes in a single Raman spectrum. An autocorrelation analysis is first carried out to accentuate the CRs feature as outliers. Subsequently, with an adequate selection of the threshold, a discrete wavelet transform filter is used to identify CR spikes. Identified data points are then replaced by interpolated values using the weighted-average interpolation technique. This approach only modifies the data in a close vicinity of the CRs. Additionally, robust wavelet transform parameters are proposed (a desirable property for automation) after optimizing them with the application of the method in a great number of spectra. However, this algorithm, as well as all the single-spectrum analysis procedures, is limited to the cases in which CRs have much narrower bandwidth than the Raman bands. This might not be the case when low-resolution Raman instruments are used.Keywords
This publication has 24 references indexed in Scilit:
- Automated Quantitative Spectroscopic Analysis Combining Background Subtraction, Cosmic Ray Removal, and Peak FittingApplied Spectroscopy, 2013
- A Fast, Automated, Polynomial-Based Cosmic Ray Spike–Removal Method for the High-Throughput Processing of Raman SpectraApplied Spectroscopy, 2013
- Automated Cosmic Spike Filter Optimized for Process Raman SpectroscopyApplied Spectroscopy, 2012
- An Improved Algorithm to Remove Cosmic Spikes in Raman Spectra for Online MonitoringApplied Spectroscopy, 2011
- Removing Cosmic Ray Features from Raman Map Data by a Refined Nearest Neighbor Comparison Method as a Precursor for Chemometric AnalysisApplied Spectroscopy, 2010
- A Practical Algorithm to Remove Cosmic Spikes in Raman Imaging Data for Pharmaceutical ApplicationsApplied Spectroscopy, 2007
- Identification of Outliers in Hyperspectral Raman Image Data by Nearest Neighbor ComparisonApplied Spectroscopy, 2002
- Removal of Cosmic Spikes from Hyper-Spectral Images Using a Hybrid Upper-Bound Spectrum MethodApplied Spectroscopy, 2002
- Stripping of Cosmic Spike Spectral Artifacts Using a New Upper-Bound Spectrum AlgorithmApplied Spectroscopy, 2001
- Simple and Efficient Method to Eliminate Spike Noise from Spectra Recorded on Charge-Coupled Device DetectorsApplied Spectroscopy, 1993