Simulation of stent deployment in a realistic human coronary artery
Authors:
- Frank Jh GijsenFGFrank Jh Gijsen
- Francesco MigliavaccaFMFrancesco Migliavacca
- Silvia SchievanoSSSilvia Schievano
- Laura SocciLSLaura Socci
- Lorenza PetriniLorenza Petrini
- Attila ThuryATAttila Thury
- Jolanda J WentzelJWJolanda J Wentzel
- Anton Fw van der SteenASAnton Fw van der Steen
- Patrick Ws SerruysPSPatrick Ws Serruys
- Gabriele DubiniGDGabriele Dubini
Open Access
- 1 January 2008
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 7 (1) , 23
Abstract
The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis. 3D reconstruction of a mildly stenosed coronary artery was carried out based on a combination of biplane angiography and intravascular ultrasound. Finite element method computations were performed to simulate the deployment of a stent inside the reconstructed coronary artery model at inflation pressure of 1.0 MPa. Strut thickness of the stent was varied to investigate stresses in the stent and the vessel wall. Deformed configurations, pressure-lumen area relationship and stress distribution in the arterial wall and stent struts were studied. The simulations show how the stent pushes the arterial wall towards the outside allowing the expansion of the occluded artery. Higher stresses in the arterial wall are present behind the stent struts and in regions where the arterial wall was thin. Values of 200 MPa for the peak stresses in the stent strut were detected near the connecting parts between the stent struts, and they were only just below the fatigue stress. Decreasing strut thickness might reduce arterial damage without increasing stresses in the struts significantly. The method presented in this paper can be used to predict stresses in the stent struts and the vessel wall, and thus evaluate whether a specific stent design is optimal for a specific patient.Keywords
This publication has 33 references indexed in Scilit:
- Clinical characteristics of stent fracture after sirolimus-eluting stent implantationInternational Journal of Cardiology, 2009
- A Numerical Model to Study the Interaction of Vascular Stents with Human Atherosclerotic LesionsAnnals of Biomedical Engineering, 2007
- Modeling Plaque Fissuring and Dissection during Balloon Angioplasty InterventionAnnals of Biomedical Engineering, 2007
- Stent expansion in curved vessel and their interactions: A finite element analysisJournal of Biomechanics, 2007
- Coronary-Artery StentsNew England Journal of Medicine, 2006
- Finite element analysis of the implantation of a balloon-expandable stent in a stenosed arteryInternational Journal of Cardiology, 2005
- Cardiovascular stent design and vessel stresses: a finite element analysisJournal of Biomechanics, 2005
- Numerical investigation of the intravascular coronary stent flexibilityJournal of Biomechanics, 2004
- Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wallBiomechanics and Modeling in Mechanobiology, 2004
- Pathobiologic Responses to Stenting 11Supported in part by grants from the National Institutes of Health (GM/HL49039 and HL03104), the Burroughs Wellcome Fund for Experimental Therapeutics, Durham, North Carolina, and the Whitaker Foundation, Rosslyn, Virginia.The American Journal of Cardiology, 1998