Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study
Open Access
- 18 August 2025
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 2861-2869
Abstract
Background: Advances in implantable cardioverter‐defibrillator (ICD) programming strategies have achieved significant reductions in inappropriate shocks. However, further refinement is needed to minimize appropriate but unnecessary therapies. The ENHANCED‐ICD study initially demonstrated the short‐term safety and efficacy of programming a number of intervals to detect (NID) of 60/80 over a median follow‐up of 1.3 years. A decade later, this study presents the long‐term impacts of this programming strategy. Objective: To assess the long‐term impact of programming NID 60/80 for ventricular tachycardia (VT)/ventricular fibrillation (VF) detection on adverse events related to shocks and arrhythmias, as well as on ICD therapies—both delivered and avoided. Methods: A retrospective analysis was conducted on 60 patients from the ENHANCED‐ICD study, a prospective, single‐center trial. The median age was 60 years, 78% were men, and 53% had a primary prevention ICD indication. A prolonged detection interval of NID 60/80 was programmed for VT/VF detection. The cycle lengths for VT/fast VT/VF were set at 360/330/240 ms, respectively. Results: After a median follow‐up of 9.4 years, Enhanced programming prevented unnecessary ICD therapies in 16.7% of patients and reduced the overall therapy rate by 25.9%. A total of 26.7% of patients received ICD therapy, with appropriate therapy delivered in 23.3% and inappropriate therapy occurring in 3.3% of patients. No arrhythmic deaths were observed, while syncope was reported in 10.0% of patients (1.63 per 100 patient‐years). Conclusion: Prolonging the ICD detection interval to an NID of 60/80 successfully prevented appropriate but unnecessary therapy, while maintaining safety during long‐term follow‐up. Trial Registration: The ENHANCED‐ICD study registered on http://ClinicalTrials.gov under study ID NCT01715116.Keywords
Funding Information
- Medtronic
This publication has 19 references indexed in Scilit:
- 2019 HRS/EHRA/APHRS/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter-defibrillator programming and testingHeart Rhythm, 2020
- Extended detection time to reduce shocks is safe in secondary prevention patients: The secondary prevention substudy of PainFree SSTHeart Rhythm, 2016
- Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)The American Journal of Cardiology, 2016
- 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testingHeart Rhythm, 2016
- Low inappropriate shock rates in patients with single- and dual/triple-chamber implantable cardioverter-defibrillators using a novel suite of detection algorithms: PainFree SST trial primary resultsHeart Rhythm, 2015
- Effect of Long-Detection Interval vs Standard-Detection Interval for Implantable Cardioverter-Defibrillators on Antitachycardia Pacing and Shock DeliveryJAMA, 2013
- Strategic Programming of Detection and Therapy Parameters in Implantable Cardioverter-Defibrillators Reduces Shocks in Primary Prevention PatientsJACC, 2008
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureNew England Journal of Medicine, 2005
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular ArrhythmiasNew England Journal of Medicine, 1997