Cheyenne S. L. Chiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheyenne S. L. Chiu has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Mathias Meine
Department of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
6 shared publications - Alexander H. Maass
Department of Cardiology, Heart Center, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
3 shared publications Maarten J. Cramer
Department of Cardiology Division Heart & Lungs University Medical Center Utrecht Utrecht The Netherlands
3 shared publications- Pim van der Harst
Department of Cardiology, University of Groningen, University Medical Center Groningen
3 shared publications - Antonius Martinus Wilhelmus van Stipdonk
Department of Cardiology, MUMC+, CARIM , P. Debyelaan 25, Maastricht 6229 HX
2 shared publications - Kevin Vernooy
Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center , Maastricht
2 shared publications
Latest Publications
- Open Access
- 14 July 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (7) , 331
QRS Area Before and After Upgrading to Cardiac Resynchronization Therapy Is Not Sufficient to Predict Outcome
QRS area reflects ventricular electrical dyssynchrony and is a stronger predictor of cardiac resynchronization therapy (CRT) outcome than QRS duration/morphology. Data on QRS area in patients upgraded from right ventricular pacing to CRT are scarce. We investigated whether QRS area and the difference with biventricular paced QRS area (ΔQRS) in CRT-upgraded patients are associated with clinical outcome and echocardiographic response. This retrospective multicenter study included patients upgraded to CRT. Median values were used as a cut-off for (Δ)QRS area. The primary composite outcome was all-cause mortality, heart transplantation or left ventricular assist device. Secondary outcomes were heart failure hospitalization (HFH) and ≥15% reduction in left ventricular end-systolic volume. A total of 303 patients were included (age 69 ± 11 years, 75% male, 50% ischemic cardiomyopathy). Median LVEF was 26% [25–34]; baseline QRS area was 132 µVs [97–162], which reduced to 90 µVs [61–122] with CRT (p < 0.001), with a ∆QRS area of 35 µVs [1–74]. The primary outcome occurred in 34.3% during 47 ± 29 months of follow-up without differences between a small or large baseline and ∆QRS area (p = 0.856; p = 0.968). HFH occurred in 9.2% and patients with large ∆QRS area had fewer HFHs (6.7% versus 15.4%, p = 0.012). Baseline QRS area of >132 µVs was not associated with HFH (p = 0.832), but was a determinant of better echocardiographic response (OR 2.23, 95% CI 1.10–4.50, p = 0.026). ∆QRS area of >35 µVs was not associated with echocardiographic response (p = 0.203). To conclude, (∆)QRS area was not associated with the primary outcome in this small cohort of CRT-upgraded patients. However, baseline QRS area of >132 µVs was associated with echocardiographic response and ∆QRS area of >35 µVs with fewer HFHs.
- 14 July 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (7) , 331
Open AccessQRS Area Before and After Upgrading to Cardiac Resynchronization Therapy Is Not Sufficient to Predict Outcome
QRS area reflects ventricular electrical dyssynchrony and is a stronger predictor of cardiac resynchronization therapy (CRT) outcome than QRS duration/morphology. Data on QRS area in patients upgraded from right ventricular pacing to CRT are scarce. We investigated whether QRS area and the difference with biventricular paced QRS area (ΔQRS) in CRT-upgraded patients are associated with clinical outcome and echocardiographic response. This retrospective multicenter study included patients upgraded to CRT. Median values were used as a cut-off for (Δ)QRS area. The primary composite outcome was all-cause mortality, heart transplantation or left ventricular assist device. Secondary outcomes were heart failure hospitalization (HFH) and ≥15% reduction in left ventricular end-systolic volume. A total of 303 patients were included (age 69 ± 11 years, 75% male, 50% ischemic cardiomyopathy). Median LVEF was 26% [25–34]; baseline QRS area was 132 µVs [97–162], which reduced to 90 µVs [61–122] with CRT (p < 0.001), with a ∆QRS area of 35 µVs [1–74]. The primary outcome occurred in 34.3% during 47 ± 29 months of follow-up without differences between a small or large baseline and ∆QRS area (p = 0.856; p = 0.968). HFH occurred in 9.2% and patients with large ∆QRS area had fewer HFHs (6.7% versus 15.4%, p = 0.012). Baseline QRS area of >132 µVs was not associated with HFH (p = 0.832), but was a determinant of better echocardiographic response (OR 2.23, 95% CI 1.10–4.50, p = 0.026). ∆QRS area of >35 µVs was not associated with echocardiographic response (p = 0.203). To conclude, (∆)QRS area was not associated with the primary outcome in this small cohort of CRT-upgraded patients. However, baseline QRS area of >132 µVs was associated with echocardiographic response and ∆QRS area of >35 µVs with fewer HFHs.
- Open Access
- 14 February 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (5) , 939-951
Left atrioventricular coupling index in patients undergoing cardiac resynchronization therapy
The left atrioventricular coupling index (LACI), defined as the ratio of left atrial (LA) to left ventricular (LV) end-diastolic volumes, serves as a surrogate for atrioventricular coupling. Cardiac resynchronization therapy (CRT) promotes reverse remodeling of both chambers and may enhance atrioventricular coupling, yet the clinical utility of LACI in CRT patients remains unclear. This study evaluated the effect of CRT on LACI and assessed its prognostic value for CRT response. In 123 patients enrolled in the ADVISE-CRT III trial (mean age 66 ± 10 years; 63% male; and 81% with a Class I CRT indication), LACI was measured by echocardiography before and six months after CRT implantation. Multivariable linear and logistic regression analyses were performed to assess the association between LACI and CRT response (≥ 15% LV end-systolic volume reduction), adjusting for potential confounders. Low baseline LACI was independently associated with an 11.2% greater LV end-systolic volume reduction (Quartile 1–2 vs. Quartile 3–4; p = 0.009) and 3.6-fold higher odds of CRT response (p = 0.041). At six months, LACI increased significantly in responders (16.5% to 20.7%; p < 0.001), driven by greater LV versus LA end-diastolic volume reduction. In non-responders, LACI remained stable (20.9% to 20.3%; p = 0.077). LACI was independently associated with CRT response and provided incremental value over individual LA and LV volumetric parameters. While LACI may reflect favorable structural substrate and atrioventricular coupling at baseline, it is not suitable for post-CRT assessment of atrioventricular coupling, as disproportionate LV versus LA remodeling may conceal coupling improvements. Graphical abstract Left atrioventricular coupling index in patients undergoing cardiac resynchronization therapy
- 14 February 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (5) , 939-951
Open AccessLeft atrioventricular coupling index in patients undergoing cardiac resynchronization therapy
The left atrioventricular coupling index (LACI), defined as the ratio of left atrial (LA) to left ventricular (LV) end-diastolic volumes, serves as a surrogate for atrioventricular coupling. Cardiac resynchronization therapy (CRT) promotes reverse remodeling of both chambers and may enhance atrioventricular coupling, yet the clinical utility of LACI in CRT patients remains unclear. This study evaluated the effect of CRT on LACI and assessed its prognostic value for CRT response. In 123 patients enrolled in the ADVISE-CRT III trial (mean age 66 ± 10 years; 63% male; and 81% with a Class I CRT indication), LACI was measured by echocardiography before and six months after CRT implantation. Multivariable linear and logistic regression analyses were performed to assess the association between LACI and CRT response (≥ 15% LV end-systolic volume reduction), adjusting for potential confounders. Low baseline LACI was independently associated with an 11.2% greater LV end-systolic volume reduction (Quartile 1–2 vs. Quartile 3–4; p = 0.009) and 3.6-fold higher odds of CRT response (p = 0.041). At six months, LACI increased significantly in responders (16.5% to 20.7%; p < 0.001), driven by greater LV versus LA end-diastolic volume reduction. In non-responders, LACI remained stable (20.9% to 20.3%; p = 0.077). LACI was independently associated with CRT response and provided incremental value over individual LA and LV volumetric parameters. While LACI may reflect favorable structural substrate and atrioventricular coupling at baseline, it is not suitable for post-CRT assessment of atrioventricular coupling, as disproportionate LV versus LA remodeling may conceal coupling improvements. Graphical abstract Left atrioventricular coupling index in patients undergoing cardiac resynchronization therapy
- Open Access
- 21 August 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 48 (10) , 1106-1113
From Clinic to Cloud: Efficacy of AI‐Assisted Remote Monitoring of Patients With Implantable Cardiac Devices
The integration of telehealth, particularly remote monitoring (RM), has profoundly improved the care of patients with cardiac implantable electronic devices (CIEDs). The recent COVID‐19 pandemic has further accelerated the adoption of RM systems. The implementation of RM to standard clinical care has been accompanied by a surge of device transmissions. Especially unscheduled transmissions have resulted in an overwhelming workload for clinicians. As the number of device transmissions is expected to increase further while clinical resources remain limited, workflow optimization is crucial. Artificial intelligence (AI) presents a promising solution. This review outlines recent advances in RM and AI applications for CIEDs. It explores the potential of AI to streamline RM workflows, reduce clinician workload, and enhance heart failure care by enabling early detection of clinical deterioration and timely intervention. In addition, key barriers to implementation are addressed, including data standardization and regulatory considerations. Beyond improving monitoring efficiency and patient outcomes, AI‐supported RM may also help expand access to care through more effective resource allocation and contribute to a more sustainable, future‐proof healthcare system.
- 21 August 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 48 (10) , 1106-1113
Open AccessFrom Clinic to Cloud: Efficacy of AI‐Assisted Remote Monitoring of Patients With Implantable Cardiac Devices
The integration of telehealth, particularly remote monitoring (RM), has profoundly improved the care of patients with cardiac implantable electronic devices (CIEDs). The recent COVID‐19 pandemic has further accelerated the adoption of RM systems. The implementation of RM to standard clinical care has been accompanied by a surge of device transmissions. Especially unscheduled transmissions have resulted in an overwhelming workload for clinicians. As the number of device transmissions is expected to increase further while clinical resources remain limited, workflow optimization is crucial. Artificial intelligence (AI) presents a promising solution. This review outlines recent advances in RM and AI applications for CIEDs. It explores the potential of AI to streamline RM workflows, reduce clinician workload, and enhance heart failure care by enabling early detection of clinical deterioration and timely intervention. In addition, key barriers to implementation are addressed, including data standardization and regulatory considerations. Beyond improving monitoring efficiency and patient outcomes, AI‐supported RM may also help expand access to care through more effective resource allocation and contribute to a more sustainable, future‐proof healthcare system.
- Open Access
- 18 August 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 2861-2869
Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study
Background: Advances in implantable cardioverter‐defibrillator (ICD) programming strategies have achieved significant reductions in inappropriate shocks. However, further refinement is needed to minimize appropriate but unnecessary therapies. The ENHANCED‐ICD study initially demonstrated the short‐term safety and efficacy of programming a number of intervals to detect (NID) of 60/80 over a median follow‐up of 1.3 years. A decade later, this study presents the long‐term impacts of this programming strategy. Objective: To assess the long‐term impact of programming NID 60/80 for ventricular tachycardia (VT)/ventricular fibrillation (VF) detection on adverse events related to shocks and arrhythmias, as well as on ICD therapies—both delivered and avoided. Methods: A retrospective analysis was conducted on 60 patients from the ENHANCED‐ICD study, a prospective, single‐center trial. The median age was 60 years, 78% were men, and 53% had a primary prevention ICD indication. A prolonged detection interval of NID 60/80 was programmed for VT/VF detection. The cycle lengths for VT/fast VT/VF were set at 360/330/240 ms, respectively. Results: After a median follow‐up of 9.4 years, Enhanced programming prevented unnecessary ICD therapies in 16.7% of patients and reduced the overall therapy rate by 25.9%. A total of 26.7% of patients received ICD therapy, with appropriate therapy delivered in 23.3% and inappropriate therapy occurring in 3.3% of patients. No arrhythmic deaths were observed, while syncope was reported in 10.0% of patients (1.63 per 100 patient‐years). Conclusion: Prolonging the ICD detection interval to an NID of 60/80 successfully prevented appropriate but unnecessary therapy, while maintaining safety during long‐term follow‐up. Trial Registration: The ENHANCED‐ICD study registered on http://ClinicalTrials.gov under study ID NCT01715116.
- 18 August 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 2861-2869
Open AccessReducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study
Background: Advances in implantable cardioverter‐defibrillator (ICD) programming strategies have achieved significant reductions in inappropriate shocks. However, further refinement is needed to minimize appropriate but unnecessary therapies. The ENHANCED‐ICD study initially demonstrated the short‐term safety and efficacy of programming a number of intervals to detect (NID) of 60/80 over a median follow‐up of 1.3 years. A decade later, this study presents the long‐term impacts of this programming strategy. Objective: To assess the long‐term impact of programming NID 60/80 for ventricular tachycardia (VT)/ventricular fibrillation (VF) detection on adverse events related to shocks and arrhythmias, as well as on ICD therapies—both delivered and avoided. Methods: A retrospective analysis was conducted on 60 patients from the ENHANCED‐ICD study, a prospective, single‐center trial. The median age was 60 years, 78% were men, and 53% had a primary prevention ICD indication. A prolonged detection interval of NID 60/80 was programmed for VT/VF detection. The cycle lengths for VT/fast VT/VF were set at 360/330/240 ms, respectively. Results: After a median follow‐up of 9.4 years, Enhanced programming prevented unnecessary ICD therapies in 16.7% of patients and reduced the overall therapy rate by 25.9%. A total of 26.7% of patients received ICD therapy, with appropriate therapy delivered in 23.3% and inappropriate therapy occurring in 3.3% of patients. No arrhythmic deaths were observed, while syncope was reported in 10.0% of patients (1.63 per 100 patient‐years). Conclusion: Prolonging the ICD detection interval to an NID of 60/80 successfully prevented appropriate but unnecessary therapy, while maintaining safety during long‐term follow‐up. Trial Registration: The ENHANCED‐ICD study registered on http://ClinicalTrials.gov under study ID NCT01715116.
- Open Access
- 5 May 2025
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 33 (6) , 184-185
Remote monitoring in implantable cardiac devices: A care solution or alert pollution?
- 5 May 2025
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 33 (6) , 184-185
Open AccessRemote monitoring in implantable cardiac devices: A care solution or alert pollution?
- Open Access
- 19 March 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (6) , 1293-1305
Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting
- 19 March 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (6) , 1293-1305
Open AccessOptimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting
- Open Access
- 14 March 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (6) , 854-863
Automatic measurement of short-term variability of repolarization captures modulation by pacing on human electrograms
- 14 March 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (6) , 854-863
Open AccessAutomatic measurement of short-term variability of repolarization captures modulation by pacing on human electrograms
- Open Access
- 19 August 2021
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 24 (2) , 256-267
Effect of remote monitoring on clinical outcomes in European heart failure patients with an implantable cardioverter-defibrillator: secondary results of the REMOTE-CIED randomized trial
Remote patient monitoring (RPM) systems offer a promising alternative to conventional In-Clinic check-ups, hereby reducing unnecessary clinic visits. Especially with the rise of the COVID-19 pandemic, this reduction is of paramount importance. Regarding the association between RPM and clinical outcomes, findings of previous studies have been inconsistent. The aim of this study is to elucidate the effect of partly substituting In-Clinic visits by RPM on clinical outcomes in implantable cardioverter-defibrillator (ICD) patients. The study included 595 heart failure patients (LVEF ≤35%; NYHA Class II/III) implanted with an ICD compatible with the Boston Scientific LATITUDE™ system. Participants were randomized to RPM plus an annual In-Clinic visit or 3–6 months In-Clinic check-ups alone. The investigated endpoints after 2 years of follow-up included a composite of all-cause mortality and cardiac hospitalization, mortality and cardiac hospitalization as independent endpoints and ICD therapy. The incidence of mortality and hospitalization did not differ significantly as independent, nor as composite endpoint between the RPM and In-Clinic group (all Ps P = 0.04). Exploratory subgroup analyses indicated that the effect of RPM differs between patients with specific characteristics, i.e. ≥60 years and permanent atrial fibrillation (all Ps < 0.05). RPM is non-inferior to conventional In-Clinic visits regarding clinical outcomes. Routine In-Clinic follow-up may partly be substituted by RPM without jeopardizing safety and efficiency, and thus reducing unnecessary In-Clinic visits. NCT01691586.
- 19 August 2021
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 24 (2) , 256-267
Open AccessEffect of remote monitoring on clinical outcomes in European heart failure patients with an implantable cardioverter-defibrillator: secondary results of the REMOTE-CIED randomized trial
Remote patient monitoring (RPM) systems offer a promising alternative to conventional In-Clinic check-ups, hereby reducing unnecessary clinic visits. Especially with the rise of the COVID-19 pandemic, this reduction is of paramount importance. Regarding the association between RPM and clinical outcomes, findings of previous studies have been inconsistent. The aim of this study is to elucidate the effect of partly substituting In-Clinic visits by RPM on clinical outcomes in implantable cardioverter-defibrillator (ICD) patients. The study included 595 heart failure patients (LVEF ≤35%; NYHA Class II/III) implanted with an ICD compatible with the Boston Scientific LATITUDE™ system. Participants were randomized to RPM plus an annual In-Clinic visit or 3–6 months In-Clinic check-ups alone. The investigated endpoints after 2 years of follow-up included a composite of all-cause mortality and cardiac hospitalization, mortality and cardiac hospitalization as independent endpoints and ICD therapy. The incidence of mortality and hospitalization did not differ significantly as independent, nor as composite endpoint between the RPM and In-Clinic group (all Ps P = 0.04). Exploratory subgroup analyses indicated that the effect of RPM differs between patients with specific characteristics, i.e. ≥60 years and permanent atrial fibrillation (all Ps < 0.05). RPM is non-inferior to conventional In-Clinic visits regarding clinical outcomes. Routine In-Clinic follow-up may partly be substituted by RPM without jeopardizing safety and efficiency, and thus reducing unnecessary In-Clinic visits. NCT01691586.