    QRS Area Before and After Upgrading to Cardiac Resynchronization Therapy Is Not Sufficient to Predict Outcome

    by Fenna Daniëls, Frederieke Eerenberg, Mariëlle Kloosterman, Antonius M. W. van Stipdonk, Cheyenne S. L. Chiu, Mathias Meine, Kevin Vernooy, Michiel Rienstra, Alexander H. Maass

    QRS area reflects ventricular electrical dyssynchrony and is a stronger predictor of cardiac resynchronization therapy (CRT) outcome than QRS duration/morphology. Data on QRS area in patients upgraded from right ventricular pacing to CRT are scarce. We investigated whether QRS area and the difference with biventricular paced QRS area (ΔQRS) in CRT-upgraded patients are associated with clinical outcome and echocardiographic response. This retrospective multicenter study included patients upgraded to CRT. Median values were used as a cut-off for (Δ)QRS area. The primary composite outcome was all-cause mortality, heart transplantation or left ventricular assist device. Secondary outcomes were heart failure hospitalization (HFH) and ≥15% reduction in left ventricular end-systolic volume. A total of 303 patients were included (age 69 ± 11 years, 75% male, 50% ischemic cardiomyopathy). Median LVEF was 26% [25–34]; baseline QRS area was 132 µVs [97–162], which reduced to 90 µVs [61–122] with CRT (p < 0.001), with a ∆QRS area of 35 µVs [1–74]. The primary outcome occurred in 34.3% during 47 ± 29 months of follow-up without differences between a small or large baseline and ∆QRS area (p = 0.856; p = 0.968). HFH occurred in 9.2% and patients with large ∆QRS area had fewer HFHs (6.7% versus 15.4%, p = 0.012). Baseline QRS area of >132 µVs was not associated with HFH (p = 0.832), but was a determinant of better echocardiographic response (OR 2.23, 95% CI 1.10–4.50, p = 0.026). ∆QRS area of >35 µVs was not associated with echocardiographic response (p = 0.203). To conclude, (∆)QRS area was not associated with the primary outcome in this small cohort of CRT-upgraded patients. However, baseline QRS area of >132 µVs was associated with echocardiographic response and ∆QRS area of >35 µVs with fewer HFHs.

  • Open Access

    Left atrioventricular coupling index in patients undergoing cardiac resynchronization therapy

    by Cheyenne S. L. Chiu, Willem Gerrits, Sophie C. Rier, Philippe C. Wouters, Maarten J. Cramer, Ivo A. C. van der Bilt, Pim van der Harst, Muhammed I. Girgin, Kevin Vernooy, Antonius M. W. van Stipdonk, et al.

    The left atrioventricular coupling index (LACI), defined as the ratio of left atrial (LA) to left ventricular (LV) end-diastolic volumes, serves as a surrogate for atrioventricular coupling. Cardiac resynchronization therapy (CRT) promotes reverse remodeling of both chambers and may enhance atrioventricular coupling, yet the clinical utility of LACI in CRT patients remains unclear. This study evaluated the effect of CRT on LACI and assessed its prognostic value for CRT response. In 123 patients enrolled in the ADVISE-CRT III trial (mean age 66 ± 10 years; 63% male; and 81% with a Class I CRT indication), LACI was measured by echocardiography before and six months after CRT implantation. Multivariable linear and logistic regression analyses were performed to assess the association between LACI and CRT response (≥ 15% LV end-systolic volume reduction), adjusting for potential confounders. Low baseline LACI was independently associated with an 11.2% greater LV end-systolic volume reduction (Quartile 1–2 vs. Quartile 3–4; p = 0.009) and 3.6-fold higher odds of CRT response (p = 0.041). At six months, LACI increased significantly in responders (16.5% to 20.7%; p < 0.001), driven by greater LV versus LA end-diastolic volume reduction. In non-responders, LACI remained stable (20.9% to 20.3%; p = 0.077). LACI was independently associated with CRT response and provided incremental value over individual LA and LV volumetric parameters. While LACI may reflect favorable structural substrate and atrioventricular coupling at baseline, it is not suitable for post-CRT assessment of atrioventricular coupling, as disproportionate LV versus LA remodeling may conceal coupling improvements. Graphical abstract Left atrioventricular coupling index in patients undergoing cardiac resynchronization therapy


  • Open Access

    From Clinic to Cloud: Efficacy of AI‐Assisted Remote Monitoring of Patients With Implantable Cardiac Devices

    by Cheyenne S. L. Chiu, Willem Gerrits, Marco Guglielmo, Maarten J. Cramer, Pim van der Harst, René van Es, Mathias Meine

    The integration of telehealth, particularly remote monitoring (RM), has profoundly improved the care of patients with cardiac implantable electronic devices (CIEDs). The recent COVID‐19 pandemic has further accelerated the adoption of RM systems. The implementation of RM to standard clinical care has been accompanied by a surge of device transmissions. Especially unscheduled transmissions have resulted in an overwhelming workload for clinicians. As the number of device transmissions is expected to increase further while clinical resources remain limited, workflow optimization is crucial. Artificial intelligence (AI) presents a promising solution. This review outlines recent advances in RM and AI applications for CIEDs. It explores the potential of AI to streamline RM workflows, reduce clinician workload, and enhance heart failure care by enabling early detection of clinical deterioration and timely intervention. In addition, key barriers to implementation are addressed, including data standardization and regulatory considerations. Beyond improving monitoring efficiency and patient outcomes, AI‐supported RM may also help expand access to care through more effective resource allocation and contribute to a more sustainable, future‐proof healthcare system.


  • Open Access

    Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study

    by Cheyenne S. L. Chiu, Akke van Dijkhuizen, Willem Gerrits, Maarten J. Cramer, Anton E. Tuinenburg, Pim van der Harst, Mathias Meine

    Background: Advances in implantable cardioverter‐defibrillator (ICD) programming strategies have achieved significant reductions in inappropriate shocks. However, further refinement is needed to minimize appropriate but unnecessary therapies. The ENHANCED‐ICD study initially demonstrated the short‐term safety and efficacy of programming a number of intervals to detect (NID) of 60/80 over a median follow‐up of 1.3 years. A decade later, this study presents the long‐term impacts of this programming strategy. Objective: To assess the long‐term impact of programming NID 60/80 for ventricular tachycardia (VT)/ventricular fibrillation (VF) detection on adverse events related to shocks and arrhythmias, as well as on ICD therapies—both delivered and avoided. Methods: A retrospective analysis was conducted on 60 patients from the ENHANCED‐ICD study, a prospective, single‐center trial. The median age was 60 years, 78% were men, and 53% had a primary prevention ICD indication. A prolonged detection interval of NID 60/80 was programmed for VT/VF detection. The cycle lengths for VT/fast VT/VF were set at 360/330/240 ms, respectively. Results: After a median follow‐up of 9.4 years, Enhanced programming prevented unnecessary ICD therapies in 16.7% of patients and reduced the overall therapy rate by 25.9%. A total of 26.7% of patients received ICD therapy, with appropriate therapy delivered in 23.3% and inappropriate therapy occurring in 3.3% of patients. No arrhythmic deaths were observed, while syncope was reported in 10.0% of patients (1.63 per 100 patient‐years). Conclusion: Prolonging the ICD detection interval to an NID of 60/80 successfully prevented appropriate but unnecessary therapy, while maintaining safety during long‐term follow‐up. Trial Registration: The ENHANCED‐ICD study registered on http://ClinicalTrials.gov under study ID NCT01715116.


  • Open Access

    Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting

    by Willem Gerrits, Philippe C. Wouters, Cheyenne S.L. Chiu, Marco Guglielmo, Maarten J. Cramer, Pim van der Harst, Kevin Vernooy, Antonius M.W. van Stipdonk, Vokko P. van Halm, Vincent F. van Dijk, et al.


  • Open Access

    Automatic measurement of short-term variability of repolarization captures modulation by pacing on human electrograms

    by Cheyenne S.L. Chiu, Vera Loen, Alfonso Aranda Hernandez, Agnieszka Smoczyńska, David J. Sprenkeler, Anton E. Tuinenburg, Coert O.S. Scheerder, Paul J. DeGroot, Marc A. Vos, Mathias Meine


  • Open Access

    Effect of remote monitoring on clinical outcomes in European heart failure patients with an implantable cardioverter-defibrillator: secondary results of the REMOTE-CIED randomized trial

    by Cheyenne S L Chiu, Ivy Timmermans, Henneke Versteeg, Edgar Zitron, Philippe Mabo, Susanne S Pedersen, Mathias Meine, for the REMOTE-CIED Trial Investigators

    Remote patient monitoring (RPM) systems offer a promising alternative to conventional In-Clinic check-ups, hereby reducing unnecessary clinic visits. Especially with the rise of the COVID-19 pandemic, this reduction is of paramount importance. Regarding the association between RPM and clinical outcomes, findings of previous studies have been inconsistent. The aim of this study is to elucidate the effect of partly substituting In-Clinic visits by RPM on clinical outcomes in implantable cardioverter-defibrillator (ICD) patients. The study included 595 heart failure patients (LVEF ≤35%; NYHA Class II/III) implanted with an ICD compatible with the Boston Scientific LATITUDE™ system. Participants were randomized to RPM plus an annual In-Clinic visit or 3–6 months In-Clinic check-ups alone. The investigated endpoints after 2 years of follow-up included a composite of all-cause mortality and cardiac hospitalization, mortality and cardiac hospitalization as independent endpoints and ICD therapy. The incidence of mortality and hospitalization did not differ significantly as independent, nor as composite endpoint between the RPM and In-Clinic group (all Ps P = 0.04). Exploratory subgroup analyses indicated that the effect of RPM differs between patients with specific characteristics, i.e. ≥60 years and permanent atrial fibrillation (all Ps < 0.05). RPM is non-inferior to conventional In-Clinic visits regarding clinical outcomes. Routine In-Clinic follow-up may partly be substituted by RPM without jeopardizing safety and efficiency, and thus reducing unnecessary In-Clinic visits. NCT01691586.