Correction Strategies for Isotopic Ratios in Overspiked Samples Using the Double Spike Technique
- 5 December 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (50) , 19965-19971
Abstract
The double spike (DS) technique is a highly effective approach for measuring the isotope ratios of many elements. However, it is common for some fraction of the prepared samples to be "overspiked." The usual solution for this problem involves repurifying and reanalyzing the samples to ensure data accuracy. Here, we propose a straightforward mathematical scheme to rectify the isotope ratios of overspiked samples, avoiding repetitive, time-consuming operations. The principle behind this scheme is that adding a standard solution with the certified isotope ratio decreases the overspiked ratio to the normal range. The related theoretical equations and a thorough error propagation model are presented. Taking nickel (Ni) isotopes as an example, we demonstrate how to utilize the spike-to-sample ratios of the overspiked sample and the sample-standard mixture, as well as the spike-subtracted isotope ratios of the mixture (delta 60Nimix), to accurately determine the actual sample isotopes. This method's accuracy and precision (2SD) were evaluated by testing Ni, chromium (Cr), and cadmium (Cd) isotope measurements. Precision consistent with traditional DS measurements can be achieved when the fraction of the added standard solution (fstd) is <= 0.60 (60%) in the mixture or when the overspiked multiple is <= 2.5. The added standard solution is recommended to be the same as the standard used to define the delta scale (e.g., delta 60Ni = 0.000 parts per thousand) to simplify the calculation procedures. This method expands the application of DS from the normal to the overspiked range and can be extended to isotope analyses of many elements where DS is applicable.Keywords
Funding Information
- National Key Research and Development Program of China (2019YFA0708400)
- State Key Laboratory of Environmental Geochemistry, Chinese Academy of Sciences (SKLEG2023210)
- State Key Laboratory of Geological Processes and Mineral Resources (MSFGPMR202402)
- Fundamental Research Funds for the Central Universities (2652023001)
- National Natural Science Foundation of China (41973018, 42373018)
This publication has 46 references indexed in Scilit:
- Nickel isotopic composition of the upper continental crustGeochimica et Cosmochimica Acta, 2022
- Heterogeneous nickel isotope compositions of the terrestrial mantle – Part 2: Mafic lithologiesGeochimica et Cosmochimica Acta, 2022
- Double-spike inversion for three-isotope systemsChemical Geology, 2017
- Precise analysis of Ca isotope ratios (δ44/40Ca) using an optimized 43Ca–42Ca double-spike MC-TIMS methodInternational Journal of Mass Spectrometry, 2013
- Ultra-precise stable Fe isotope measurements by high resolution multiple-collector inductively coupled plasma mass spectrometry with a 57Fe–58Fe double spikeChemical Geology, 2012
- A new methodology for precise cadmium isotope analyses of seawaterAnalytical and Bioanalytical Chemistry, 2011
- The double spike toolboxChemical Geology, 2009
- The stable Cr isotope inventory of solid Earth reservoirs determined by double spike MC-ICP-MSChemical Geology, 2008
- Precise and accurate isotopic measurements using multiple-collector ICPMSGeochimica et Cosmochimica Acta, 2004