Decan Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Decan Tan has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Jian-Ming Zhu
State Key Laboratory of Geological Processes and Mineral Resources
9 shared publications - Xiangli Wang
Key Laboratory of Cenozoic Geology and Environment, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
5 shared publications - Guilin Han
State Key Laboratory of Geomicrobiology and Environmental Changes, Institute of Earth Sciences, China University of Geosciences (Beijing), Beijing, 100083, China; Frontiers Science Center for Deep-time Digital Earth, China University of Geosciences (Beijing), Beijing, 100083, China
3 shared publications Wenpo Xu
State Key Laboratory of Geological Processes and Mineral Resources
3 shared publications- Zhuo Lu
State Key Laboratory of Geological Processes and Mineral Resources, Frontiers Science Center for Deep-time Digital Earth, China University of Geosciences (Beijing), Beijing, 100083, China
3 shared publications - Guangliang Wu
State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences (Beijing), Beijing 100083, China
2 shared publications
Latest Publications
- Top Cited Papers
- 14 January 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (7) , 3737-3748
Experimental Investigation of Cadmium Isotope Fractionation during Adsorption on Montmorillonite and Kaolinite
Cadmium (Cd) isotopes have recently emerged as novel tracers of Cd sources and geochemical processes. Widespread clay minerals play a key role in Cd migration due to their strong adsorption capacity, but the mechanism of Cd isotope fractionation during adsorption onto clay minerals is poorly understood. Here, we experimentally investigated the adsorption mechanisms of Cd on montmorillonite (2:1) and kaolinite (1:1) by using extended X-ray absorption fine structure (EXAFS) spectroscopy. Our results show that lighter Cd isotopes are preferentially adsorbed on clay minerals, with Δ114/110Cddissolved-adsorbed values of 0.03 ± 0.02‰ for montmorillonite and 0.03 ± 0.03‰ for kaolinite. These values are independent of the pH, initial Cd concentration, and ionic strength. EXAFS indicate that the adsorbed Cd forms octahedral outer-sphere surface complexes with an average Cd-O bond length of 2.25-2.26 Å, identical to Cd-O bonding environment in the Cd(NO3)2 solution. Our results demonstrate that the extent of Cd isotope fractionation is constrained by structural changes (including the bond length and coordination number) in surface complexes. These findings suggest that Cd adsorption on clay minerals has a minimal impact on the variability of Cd isotopic compositions in soils and sediments, implying that variations in Cd isotope ratios in soils and sediments primarily reflect changes in Cd sources.
- 14 January 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (7) , 3737-3748
Top Cited PapersExperimental Investigation of Cadmium Isotope Fractionation during Adsorption on Montmorillonite and Kaolinite
Cadmium (Cd) isotopes have recently emerged as novel tracers of Cd sources and geochemical processes. Widespread clay minerals play a key role in Cd migration due to their strong adsorption capacity, but the mechanism of Cd isotope fractionation during adsorption onto clay minerals is poorly understood. Here, we experimentally investigated the adsorption mechanisms of Cd on montmorillonite (2:1) and kaolinite (1:1) by using extended X-ray absorption fine structure (EXAFS) spectroscopy. Our results show that lighter Cd isotopes are preferentially adsorbed on clay minerals, with Δ114/110Cddissolved-adsorbed values of 0.03 ± 0.02‰ for montmorillonite and 0.03 ± 0.03‰ for kaolinite. These values are independent of the pH, initial Cd concentration, and ionic strength. EXAFS indicate that the adsorbed Cd forms octahedral outer-sphere surface complexes with an average Cd-O bond length of 2.25-2.26 Å, identical to Cd-O bonding environment in the Cd(NO3)2 solution. Our results demonstrate that the extent of Cd isotope fractionation is constrained by structural changes (including the bond length and coordination number) in surface complexes. These findings suggest that Cd adsorption on clay minerals has a minimal impact on the variability of Cd isotopic compositions in soils and sediments, implying that variations in Cd isotope ratios in soils and sediments primarily reflect changes in Cd sources.
- 5 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (50) , 19965-19971
Correction Strategies for Isotopic Ratios in Overspiked Samples Using the Double Spike Technique
The double spike (DS) technique is a highly effective approach for measuring the isotope ratios of many elements. However, it is common for some fraction of the prepared samples to be "overspiked." The usual solution for this problem involves repurifying and reanalyzing the samples to ensure data accuracy. Here, we propose a straightforward mathematical scheme to rectify the isotope ratios of overspiked samples, avoiding repetitive, time-consuming operations. The principle behind this scheme is that adding a standard solution with the certified isotope ratio decreases the overspiked ratio to the normal range. The related theoretical equations and a thorough error propagation model are presented. Taking nickel (Ni) isotopes as an example, we demonstrate how to utilize the spike-to-sample ratios of the overspiked sample and the sample-standard mixture, as well as the spike-subtracted isotope ratios of the mixture (delta 60Nimix), to accurately determine the actual sample isotopes. This method's accuracy and precision (2SD) were evaluated by testing Ni, chromium (Cr), and cadmium (Cd) isotope measurements. Precision consistent with traditional DS measurements can be achieved when the fraction of the added standard solution (fstd) is <= 0.60 (60%) in the mixture or when the overspiked multiple is <= 2.5. The added standard solution is recommended to be the same as the standard used to define the delta scale (e.g., delta 60Ni = 0.000 parts per thousand) to simplify the calculation procedures. This method expands the application of DS from the normal to the overspiked range and can be extended to isotope analyses of many elements where DS is applicable.
- 5 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (50) , 19965-19971
Correction Strategies for Isotopic Ratios in Overspiked Samples Using the Double Spike Technique
The double spike (DS) technique is a highly effective approach for measuring the isotope ratios of many elements. However, it is common for some fraction of the prepared samples to be "overspiked." The usual solution for this problem involves repurifying and reanalyzing the samples to ensure data accuracy. Here, we propose a straightforward mathematical scheme to rectify the isotope ratios of overspiked samples, avoiding repetitive, time-consuming operations. The principle behind this scheme is that adding a standard solution with the certified isotope ratio decreases the overspiked ratio to the normal range. The related theoretical equations and a thorough error propagation model are presented. Taking nickel (Ni) isotopes as an example, we demonstrate how to utilize the spike-to-sample ratios of the overspiked sample and the sample-standard mixture, as well as the spike-subtracted isotope ratios of the mixture (delta 60Nimix), to accurately determine the actual sample isotopes. This method's accuracy and precision (2SD) were evaluated by testing Ni, chromium (Cr), and cadmium (Cd) isotope measurements. Precision consistent with traditional DS measurements can be achieved when the fraction of the added standard solution (fstd) is <= 0.60 (60%) in the mixture or when the overspiked multiple is <= 2.5. The added standard solution is recommended to be the same as the standard used to define the delta scale (e.g., delta 60Ni = 0.000 parts per thousand) to simplify the calculation procedures. This method expands the application of DS from the normal to the overspiked range and can be extended to isotope analyses of many elements where DS is applicable.
- 2 November 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (12) , 3082-3093
Applying standard addition to determine antimony isotopes in low-Sb samples using HG-MC-ICP-MS
The δ123Sb value of BCR-2 obtained by the standard addition (SA) method.
- 2 November 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (12) , 3082-3093
Applying standard addition to determine antimony isotopes in low-Sb samples using HG-MC-ICP-MS
The δ123Sb value of BCR-2 obtained by the standard addition (SA) method.
- 18 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (5) , 1063-1075
Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS
With recent advancements in analytical methods of Mo isotopes, the δ98/95Mo ratios of most geological and environmental samples can be determined. Still, it remains a challenge to obtain high-precision Mo isotope data for low-Mo samples with complex matrices such as igneous and plant samples. Here, we present an improved Mo purification and cleaning resin scheme for reducing the total procedure blank to ≤0.16 ng using common Muromac®1X8(AG1-X8) anion and AG50-X8 cation resins. By an improved Aridus II with ice chamber in sample introduction system (SIS) and adding nitrogen (N2), high sensitivity measurement (95Mo signal intensity: 200–330 V ppm−1) of Mo isotopes was achieved on Neptune Plus MC-ICP-MS. Thus, the sample size containing 30–60 ng Mo is sufficient to be purified, and isotope measurement with high-precision (≤0.06‰, 2SD) can be determined at a concentration of 3–10 ng level using a 97Mo–100Mo double spike. NIST 3134 (0.00 ± 0.05‰), SGR-1b (0.41 ± 0.05‰), NOD-P-1 (−0.86 ± 0.03‰), IAPSO (2.07 ± 0.04‰), and other international reference materials (RMs) were analyzed at 3, 5, 10, and 20 ng mL−1 levels to be in excellent agreement with the published δ98/95Mo values, demonstrating that good accuracy and precision of Mo isotope analysis can be achieved with an injecting sample size as small as 5 ng Mo. Our improved method can be applied to various geological and environmental samples. The δ98/95Mo of CLB-1 (1.25 ± 0.03‰), JDO-1 (0.50 ± 0.02‰), GSV-2 (0.47 ± 0.02‰), and other 38 RMs with relatively higher and lower Mo concentrations are reported for the first time. The total average δ98/95Mo ratio of 8 soils and 18 sediments is 0.003 ± 0.277‰ (1SD, n = 26), slightly lighter than that of the upper continent crust (0.05–0.15‰). The δ98/95Mo ratios (0.23–0.79‰, n = 8) of plant and animal origins from the land show they are enriched in heavy isotopes relative to the bulk silicate earth (BSE). The δ98/95Mo ratios of carbonates are much lower than that in seawater.
- 18 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (5) , 1063-1075
Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS
With recent advancements in analytical methods of Mo isotopes, the δ98/95Mo ratios of most geological and environmental samples can be determined. Still, it remains a challenge to obtain high-precision Mo isotope data for low-Mo samples with complex matrices such as igneous and plant samples. Here, we present an improved Mo purification and cleaning resin scheme for reducing the total procedure blank to ≤0.16 ng using common Muromac®1X8(AG1-X8) anion and AG50-X8 cation resins. By an improved Aridus II with ice chamber in sample introduction system (SIS) and adding nitrogen (N2), high sensitivity measurement (95Mo signal intensity: 200–330 V ppm−1) of Mo isotopes was achieved on Neptune Plus MC-ICP-MS. Thus, the sample size containing 30–60 ng Mo is sufficient to be purified, and isotope measurement with high-precision (≤0.06‰, 2SD) can be determined at a concentration of 3–10 ng level using a 97Mo–100Mo double spike. NIST 3134 (0.00 ± 0.05‰), SGR-1b (0.41 ± 0.05‰), NOD-P-1 (−0.86 ± 0.03‰), IAPSO (2.07 ± 0.04‰), and other international reference materials (RMs) were analyzed at 3, 5, 10, and 20 ng mL−1 levels to be in excellent agreement with the published δ98/95Mo values, demonstrating that good accuracy and precision of Mo isotope analysis can be achieved with an injecting sample size as small as 5 ng Mo. Our improved method can be applied to various geological and environmental samples. The δ98/95Mo of CLB-1 (1.25 ± 0.03‰), JDO-1 (0.50 ± 0.02‰), GSV-2 (0.47 ± 0.02‰), and other 38 RMs with relatively higher and lower Mo concentrations are reported for the first time. The total average δ98/95Mo ratio of 8 soils and 18 sediments is 0.003 ± 0.277‰ (1SD, n = 26), slightly lighter than that of the upper continent crust (0.05–0.15‰). The δ98/95Mo ratios (0.23–0.79‰, n = 8) of plant and animal origins from the land show they are enriched in heavy isotopes relative to the bulk silicate earth (BSE). The δ98/95Mo ratios of carbonates are much lower than that in seawater.
- 10 March 2021
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 45 (3) , 565-581
δ114/110Cd Values of a Suite of Different Reference Materials
The δ114/110Cd values of thirty‐four environmental and geological reference materials, including rocks, sediments, soils and biological samples, were determined on a Neptune Plus MC‐ICP‐MS instrument using a 111Cd‐113Cd double spike technique. An intermediate measurement precision of better than ± 0.074‰ (2s) was achieved with different reference materials (RMs) of highly variable matrices and Cd contents. The uncertainty of δ114/110Cd values was assessed by calculating the 95% confidence interval of the results from this study and the literature using Student's t‐test. Our measurements of nine previously analysed RMs yielded δ114/110Cd values that were indistinguishable from previous results. New reference values for the thirty‐four geological and biological RMs are reported here. The comprehensive data set for these RMs provides guidelines for quality assurance and inter‐laboratory comparison for Cd isotope determination. The large range of δ114/110Cd values in rock (−0.001 to +0.287‰) and biological RMs (−0.806 to +0.142‰) suggests that Cd isotope ratio measurement results are a useful tool to study biogeochemical processes.
- 10 March 2021
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 45 (3) , 565-581
δ114/110Cd Values of a Suite of Different Reference Materials
The δ114/110Cd values of thirty‐four environmental and geological reference materials, including rocks, sediments, soils and biological samples, were determined on a Neptune Plus MC‐ICP‐MS instrument using a 111Cd‐113Cd double spike technique. An intermediate measurement precision of better than ± 0.074‰ (2s) was achieved with different reference materials (RMs) of highly variable matrices and Cd contents. The uncertainty of δ114/110Cd values was assessed by calculating the 95% confidence interval of the results from this study and the literature using Student's t‐test. Our measurements of nine previously analysed RMs yielded δ114/110Cd values that were indistinguishable from previous results. New reference values for the thirty‐four geological and biological RMs are reported here. The comprehensive data set for these RMs provides guidelines for quality assurance and inter‐laboratory comparison for Cd isotope determination. The large range of δ114/110Cd values in rock (−0.001 to +0.287‰) and biological RMs (−0.806 to +0.142‰) suggests that Cd isotope ratio measurement results are a useful tool to study biogeochemical processes.
- 1 May 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 277, 21-36
Equilibrium fractionation and isotope exchange kinetics between aqueous Se(IV) and Se(VI)
- 1 May 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 277, 21-36
Equilibrium fractionation and isotope exchange kinetics between aqueous Se(IV) and Se(VI)
- 17 March 2020
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 44 (3) , 523-535
The δ60/58Ni Values of Twenty‐Six Selected Geological Reference Materials
The high‐precision δ60/58Ni values of twenty‐six geological reference materials, including igneous rocks, sedimentary rocks, stream sediments, soils and plants are reported. The δ60/58Ni values of all samples were determined by double‐spike MC‐ICP‐MS (Nu Plasma III). Isotope standard solution (NIST SRM 986) and geological reference materials (BHVO‐2, BCR‐2, JP‐1, PCC‐1, etc.) were used to evaluate the measurement bias and intermediate precision over a period of six months. Our results show that the intermediate precision of Ni isotope determination was 0.05‰ (2s,n = 69) for spiked NIST SRM 986 and typically 0.06‰ for actual samples, and the δ60/58NiNIST SRM 986values were in excellent agreement with previous studies. Eighteen high‐precision Ni isotope ratios of geological reference materials are first reported here, and their δ60/58Ni values varied from −0.27‰ to 0.52‰, with a mean of 0.13 ± 0.34‰ (2s,n = 18). Additionally, SGR‐1b (0.56 ± 0.04‰, 2s), GSS‐1 (−0.27 ± 0.06‰, 2s), GSS‐7 (−0.11 ± 0.01‰, 2s), GSD‐10 (0.46 ± 0.06‰, 2s) and GSB‐12 (0.52 ± 0.06‰, 2s) could potentially serve as candidate reference materials for Ni isotope fractionation and comparison of Ni isotopic compositions among different laboratories.
- 17 March 2020
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 44 (3) , 523-535
The δ60/58Ni Values of Twenty‐Six Selected Geological Reference Materials
The high‐precision δ60/58Ni values of twenty‐six geological reference materials, including igneous rocks, sedimentary rocks, stream sediments, soils and plants are reported. The δ60/58Ni values of all samples were determined by double‐spike MC‐ICP‐MS (Nu Plasma III). Isotope standard solution (NIST SRM 986) and geological reference materials (BHVO‐2, BCR‐2, JP‐1, PCC‐1, etc.) were used to evaluate the measurement bias and intermediate precision over a period of six months. Our results show that the intermediate precision of Ni isotope determination was 0.05‰ (2s,n = 69) for spiked NIST SRM 986 and typically 0.06‰ for actual samples, and the δ60/58NiNIST SRM 986values were in excellent agreement with previous studies. Eighteen high‐precision Ni isotope ratios of geological reference materials are first reported here, and their δ60/58Ni values varied from −0.27‰ to 0.52‰, with a mean of 0.13 ± 0.34‰ (2s,n = 18). Additionally, SGR‐1b (0.56 ± 0.04‰, 2s), GSS‐1 (−0.27 ± 0.06‰, 2s), GSS‐7 (−0.11 ± 0.01‰, 2s), GSD‐10 (0.46 ± 0.06‰, 2s) and GSB‐12 (0.52 ± 0.06‰, 2s) could potentially serve as candidate reference materials for Ni isotope fractionation and comparison of Ni isotopic compositions among different laboratories.
- 1 March 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 272, 121-136
Selenium isotope fractionation during adsorption by Fe, Mn and Al oxides
- 1 March 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 272, 121-136
Selenium isotope fractionation during adsorption by Fe, Mn and Al oxides
- 15 January 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (4) , 713-727
High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
With new advancements in MC-ICP-MS technology, small Cd isotope fractionations in geological processes have attracted more interest in recent years. However, challenges remain in obtaining high-precision Cd isotope data for geological samples with low Cd concentrations and complex matrices. By an improved Cd purification and cleaning resin scheme for low-Cd samples using AGMP-1M resin with >90% Cd recovery, the ratios of trace elements Sn, Mo, Zr, etc. to Cd in the samples, which could potentially jeopardize the accuracy and precision of Cd isotope analysis under a high-sensitivity setup, were less than 0.001 after purification, and the total procedure blank is ≤0.1 ng. Hence, a sample containing 20–30 ng Cd can be employed for purification and subsequent isotope measurement. Cadmium isotope fractionation (expressed in δ114/110Cd relative to NIST 3108) during column separation and instrument mass bias was corrected for by a 111Cd–113Cd double spike. NIST 3108 was determined at a concentration of 5–25 ng mL−1 on a Neptune Plus (112Cd signal intensity: ∼640 V ppm−1) and 25–50 ng mL−1 on a Nu plasma III (112Cd signal intensity:∼280 V ppm−1) MC-ICP-MS equipped with an Aridus II/III desolvator for more than one year, with a total external analytical precision of 0.034‰ (2SD, n = 181). NIST SRM 2711a, NOD-P-1 and GSS-1 were measured at 5, 10, 20, 25 and 50 ng mL−1 levels to be 0.532 ± 0.038‰, 0.133 ± 0.038‰ and 0.098 ± 0.027‰, respectively, indicating that good accuracy and precision of Cd isotope analysis can be achieved with an injecting sample size as low as 5 ng Cd. Our method can be reliably applied to various geological reference materials (GRMs). The δ114/110Cd values of GRMs with relatively high and low Cd concentrations are consistent with previous studies: NOD-A-1 (0.124 ± 0.067‰), GSD-11 (−0.274 ± 0.037‰) and BCR-2 (−0.030 ± 0.063‰). SGR-1b (0.069 ± 0.049‰), GSH-1 (−0.337 ± 0.077‰) and others are reported for the first time in this paper. The δ114/110Cd in basalt and stream sediments is relatively homogeneous and overlaps with that of the bulk silicate earth (BSE). The δ114/110Cd in shale and soils varies greatly from −0.694 to 0.532‰. Human hair and other animal organs are enriched in light isotopes relative to BSE, whereas terrestrial plants are enriched in heavy isotopes.
- 15 January 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (4) , 713-727
High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
With new advancements in MC-ICP-MS technology, small Cd isotope fractionations in geological processes have attracted more interest in recent years. However, challenges remain in obtaining high-precision Cd isotope data for geological samples with low Cd concentrations and complex matrices. By an improved Cd purification and cleaning resin scheme for low-Cd samples using AGMP-1M resin with >90% Cd recovery, the ratios of trace elements Sn, Mo, Zr, etc. to Cd in the samples, which could potentially jeopardize the accuracy and precision of Cd isotope analysis under a high-sensitivity setup, were less than 0.001 after purification, and the total procedure blank is ≤0.1 ng. Hence, a sample containing 20–30 ng Cd can be employed for purification and subsequent isotope measurement. Cadmium isotope fractionation (expressed in δ114/110Cd relative to NIST 3108) during column separation and instrument mass bias was corrected for by a 111Cd–113Cd double spike. NIST 3108 was determined at a concentration of 5–25 ng mL−1 on a Neptune Plus (112Cd signal intensity: ∼640 V ppm−1) and 25–50 ng mL−1 on a Nu plasma III (112Cd signal intensity:∼280 V ppm−1) MC-ICP-MS equipped with an Aridus II/III desolvator for more than one year, with a total external analytical precision of 0.034‰ (2SD, n = 181). NIST SRM 2711a, NOD-P-1 and GSS-1 were measured at 5, 10, 20, 25 and 50 ng mL−1 levels to be 0.532 ± 0.038‰, 0.133 ± 0.038‰ and 0.098 ± 0.027‰, respectively, indicating that good accuracy and precision of Cd isotope analysis can be achieved with an injecting sample size as low as 5 ng Cd. Our method can be reliably applied to various geological reference materials (GRMs). The δ114/110Cd values of GRMs with relatively high and low Cd concentrations are consistent with previous studies: NOD-A-1 (0.124 ± 0.067‰), GSD-11 (−0.274 ± 0.037‰) and BCR-2 (−0.030 ± 0.063‰). SGR-1b (0.069 ± 0.049‰), GSH-1 (−0.337 ± 0.077‰) and others are reported for the first time in this paper. The δ114/110Cd in basalt and stream sediments is relatively homogeneous and overlaps with that of the bulk silicate earth (BSE). The δ114/110Cd in shale and soils varies greatly from −0.694 to 0.532‰. Human hair and other animal organs are enriched in light isotopes relative to BSE, whereas terrestrial plants are enriched in heavy isotopes.
- 2 January 2020
- Published by Springer Nature in Acta Geochimica
- Vol. 39 (2) , 192-202
Optimizing the ratio of the spike to sample for isotope dilution analysis: a case study with selenium isotopes
- 2 January 2020
- Published by Springer Nature in Acta Geochimica
- Vol. 39 (2) , 192-202
Optimizing the ratio of the spike to sample for isotope dilution analysis: a case study with selenium isotopes