Multi-ROI Spectral Approach for the Continuous Remote Cardio-Respiratory Monitoring from Mobile Device Built-In Cameras
Open Access
Abstract
Heart rate (HR) and respiratory rate (fR) can be estimated by processing videos framing the upper body and face regions without any physical contact with the subject. This paper proposed a technique for continuously monitoring HR and fR via a multi-ROI approach based on the spectral analysis of RGB video frames recorded with a mobile device (i.e., a smartphone’s camera). The respiratory signal was estimated by the motion of the chest, whereas the cardiac signal was retrieved from the pulsatile activity at the level of right and left cheeks and forehead. Videos were recorded from 18 healthy volunteers in four sessions with different user-camera distances (i.e., 0.5 m and 1.0 m) and illumination conditions (i.e., natural and artificial light). For HR estimation, three approaches were investigated based on single or multi-ROI approaches. A commercially available multiparametric device was used to record reference respiratory signals and electrocardiogram (ECG). The results demonstrated that the multi-ROI approach outperforms the single-ROI approach providing temporal trends of both the vital parameters comparable to those provided by the reference, with a mean absolute error (MAE) consistently below 1 breaths·min−1 for fR in all the scenarios, and a MAE between 0.7 bpm and 6 bpm for HR estimation, whose values increase at higher distances.Keywords
Funding Information
- POR Lazio FSE 2014/2020 (CUP code n. F87C21000190009, Project ID 23562)
This publication has 57 references indexed in Scilit:
- Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit TimeIEEE Transactions on Biomedical Engineering, 2014
- Signal recovery in imaging photoplethysmographyPhysiological Measurement, 2013
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- Measuring Pulse Rate with a WebcamJournal of Medical Imaging and Health Informatics, 2012
- Principal component analysisWIREs Computational Statistics, 2010
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- An advanced detrending method with application to HRV analysisIEEE Transactions on Biomedical Engineering, 2002
- Modulatory effects of respirationAutonomic Neuroscience, 2001
- Determining optical flowArtificial Intelligence, 1981