Nunzia Molinaro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nunzia Molinaro has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Massaroni
Università Campus Bio-Medico di Roma
4 shared publications - Sergio Silvestri
Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy
4 shared publications - Emiliano Schena
Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128 Rome, Italy
3 shared publications Emiliano Schena
Unit of Measurements and Biomedical Instrumentation, Universit Campus Bio-Medico di Roma, Rome, Italy
1 shared publicationFederico Zangarelli
Departmental Faculty of Engineering, Unit of Measurements and Biomedical Instrumentation, Universit Campus Bio-Medico di Roma, Rome, Italy
1 shared publication- Shekh Md Mahmudul Islam
Department of Electrical and Electronic Engineering, University of Dhaka, Dhaka, Bangladesh
1 shared publication
Latest Publications
- Open Access
Breathing Chest Wall Kinematics Assessment through a Single Digital Camera: A Feasibility Study
The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual’s health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements. However, alternative technologies able to capture chest wall movements without physical contact, such as RGB digital cameras and time-of-flight digital cameras, can also be utilized due to their accessibility, affordability, and non-invasive nature. This study explores the possibility of using a single RGB digital camera to record the kinematics of the thoracic and abdominal regions by placing four non-reflective markers on the torso. In order to choose the positions of these markers, we previously investigated the movements of 89 chest wall landmarks using OEP. Laboratory tests and volunteer experiments were conducted to assess the viability of the proposed system in capturing the kinematics of the chest wall and estimating various time-related respiratory parameters (i.e., fR, Ti, Te, and Ttot) as well as TAA indexes. The results demonstrate a high level of agreement between the detected chest wall kinematics and the reference data. Furthermore, the system shows promising potential in estimating time-related respiratory parameters and identifying phase shifts indicative of TAA, thus suggesting its feasibility in detecting abnormal chest wall movements without physical contact with a single RGB camera.
Open AccessBreathing Chest Wall Kinematics Assessment through a Single Digital Camera: A Feasibility Study
The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual’s health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements. However, alternative technologies able to capture chest wall movements without physical contact, such as RGB digital cameras and time-of-flight digital cameras, can also be utilized due to their accessibility, affordability, and non-invasive nature. This study explores the possibility of using a single RGB digital camera to record the kinematics of the thoracic and abdominal regions by placing four non-reflective markers on the torso. In order to choose the positions of these markers, we previously investigated the movements of 89 chest wall landmarks using OEP. Laboratory tests and volunteer experiments were conducted to assess the viability of the proposed system in capturing the kinematics of the chest wall and estimating various time-related respiratory parameters (i.e., fR, Ti, Te, and Ttot) as well as TAA indexes. The results demonstrate a high level of agreement between the detected chest wall kinematics and the reference data. Furthermore, the system shows promising potential in estimating time-related respiratory parameters and identifying phase shifts indicative of TAA, thus suggesting its feasibility in detecting abnormal chest wall movements without physical contact with a single RGB camera.
- Open Access
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (17) , 20097-20106
Cardiorespiratory Parameters Monitoring Through a Single Digital Camera in Real Scenarios: ROI Tracking and Motion Influence
Monitoring of heart rate (HR) and respiratory rate ( fR ) is fundamental to assess the health status of an individual. To address this scope, technologies which frame the upper body and the face regions of a subject without any physical contact can be used. Motion artifacts can affect the applicability of non-contact methods to the continuous monitoring of these parameters as well as the computational burden. This paper focuses on a technique based on images captured with a single digital camera for the continuous estimation of HR and fR . The main goal is to analyze how velocity of face movements and ROI tracking duration influence the performance of the method. Tests were performed on healthy volunteers during motionless trials (i.e., at rest and after exercise), head and torso movements, and during physical exercise. Results demonstrated that a continuous estimation of HR and fR can be performed with acceptable errors under changing ROI tracking duration and velocity in motionless trials (MAE below 5 bpm and 3.42 breaths∙min -1 for HR and fR , respectively), whereas during movements (mimicking head and torso movements, and during exercise) the error increases (MAE up to 5.42 bpm and up to 5.03 breaths∙min -1 for HR and fR , respectively). The proposed investigation can provide a framework for the continuous estimation of HR and fR during both static and dynamic activities by optimizing the ROI tracking duration under different velocity of face movements.
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (17) , 20097-20106
Open AccessCardiorespiratory Parameters Monitoring Through a Single Digital Camera in Real Scenarios: ROI Tracking and Motion Influence
Monitoring of heart rate (HR) and respiratory rate ( fR ) is fundamental to assess the health status of an individual. To address this scope, technologies which frame the upper body and the face regions of a subject without any physical contact can be used. Motion artifacts can affect the applicability of non-contact methods to the continuous monitoring of these parameters as well as the computational burden. This paper focuses on a technique based on images captured with a single digital camera for the continuous estimation of HR and fR . The main goal is to analyze how velocity of face movements and ROI tracking duration influence the performance of the method. Tests were performed on healthy volunteers during motionless trials (i.e., at rest and after exercise), head and torso movements, and during physical exercise. Results demonstrated that a continuous estimation of HR and fR can be performed with acceptable errors under changing ROI tracking duration and velocity in motionless trials (MAE below 5 bpm and 3.42 breaths∙min -1 for HR and fR , respectively), whereas during movements (mimicking head and torso movements, and during exercise) the error increases (MAE up to 5.42 bpm and up to 5.03 breaths∙min -1 for HR and fR , respectively). The proposed investigation can provide a framework for the continuous estimation of HR and fR during both static and dynamic activities by optimizing the ROI tracking duration under different velocity of face movements.
- 29 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 53 (3) , 642-651
Respiratory Feature Extraction for Contactless Breathing Pattern Recognition Using a Single Digital Camera
Non-contact respiratory monitoring is gaining attention due to its unobtrusive form of measurement. Among all other non-contact sensing modalities, optical sensors integrated with commercial video cameras have received more attention due to their ease of use and low cost, allowing non-experts to employ these methods without any prior knowledge. Prior research mostly focused on extracting breathing rate and heart rate-related information for sedentary breathing patterns using camera to determine health status. However, for abnormal breathing patterns, a range of respiratory-pattern-related signatures need to be monitored to investigate the associated primary cause of pattern change. In this paper, we propose a novel feature extraction technique to recognize respiratory patterns such as eupnea, tachypnea, bradypnea, and apnea retrieved from videos captured using a single digital camera working in the visible range. At this aim, a hyper-feature algorithm has been implemented to extract distinguishable air-flow-related from videos collected on twenty-four participants having four different respiratory patterns. After the training of the algorithm using the reference respiratory signal obtained from a medical-grade chest strap, the performance of the system has been evaluated on additional five participants whose measurement was not used for algorithm development and on seven patients. Results demonstrated an accuracy of 96.07% in the recognition of all the respiratory patterns, with minimum performances (81.81%) in detecting bradypnea and 100% in detecting apnea events. Additionally, including the patient’s dataset with the apnea and the normal breathing pattern, the accuracy of the proposed algorithm becomes 97.39%, demonstrating its robustness on the patient’s dataset.
- 29 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 53 (3) , 642-651
Respiratory Feature Extraction for Contactless Breathing Pattern Recognition Using a Single Digital Camera
Non-contact respiratory monitoring is gaining attention due to its unobtrusive form of measurement. Among all other non-contact sensing modalities, optical sensors integrated with commercial video cameras have received more attention due to their ease of use and low cost, allowing non-experts to employ these methods without any prior knowledge. Prior research mostly focused on extracting breathing rate and heart rate-related information for sedentary breathing patterns using camera to determine health status. However, for abnormal breathing patterns, a range of respiratory-pattern-related signatures need to be monitored to investigate the associated primary cause of pattern change. In this paper, we propose a novel feature extraction technique to recognize respiratory patterns such as eupnea, tachypnea, bradypnea, and apnea retrieved from videos captured using a single digital camera working in the visible range. At this aim, a hyper-feature algorithm has been implemented to extract distinguishable air-flow-related from videos collected on twenty-four participants having four different respiratory patterns. After the training of the algorithm using the reference respiratory signal obtained from a medical-grade chest strap, the performance of the system has been evaluated on additional five participants whose measurement was not used for algorithm development and on seven patients. Results demonstrated an accuracy of 96.07% in the recognition of all the respiratory patterns, with minimum performances (81.81%) in detecting bradypnea and 100% in detecting apnea events. Additionally, including the patient’s dataset with the apnea and the normal breathing pattern, the accuracy of the proposed algorithm becomes 97.39%, demonstrating its robustness on the patient’s dataset.
- Open Access
Multi-ROI Spectral Approach for the Continuous Remote Cardio-Respiratory Monitoring from Mobile Device Built-In Cameras
Heart rate (HR) and respiratory rate (fR) can be estimated by processing videos framing the upper body and face regions without any physical contact with the subject. This paper proposed a technique for continuously monitoring HR and fR via a multi-ROI approach based on the spectral analysis of RGB video frames recorded with a mobile device (i.e., a smartphone’s camera). The respiratory signal was estimated by the motion of the chest, whereas the cardiac signal was retrieved from the pulsatile activity at the level of right and left cheeks and forehead. Videos were recorded from 18 healthy volunteers in four sessions with different user-camera distances (i.e., 0.5 m and 1.0 m) and illumination conditions (i.e., natural and artificial light). For HR estimation, three approaches were investigated based on single or multi-ROI approaches. A commercially available multiparametric device was used to record reference respiratory signals and electrocardiogram (ECG). The results demonstrated that the multi-ROI approach outperforms the single-ROI approach providing temporal trends of both the vital parameters comparable to those provided by the reference, with a mean absolute error (MAE) consistently below 1 breaths·min−1 for fR in all the scenarios, and a MAE between 0.7 bpm and 6 bpm for HR estimation, whose values increase at higher distances.
Open AccessMulti-ROI Spectral Approach for the Continuous Remote Cardio-Respiratory Monitoring from Mobile Device Built-In Cameras
Heart rate (HR) and respiratory rate (fR) can be estimated by processing videos framing the upper body and face regions without any physical contact with the subject. This paper proposed a technique for continuously monitoring HR and fR via a multi-ROI approach based on the spectral analysis of RGB video frames recorded with a mobile device (i.e., a smartphone’s camera). The respiratory signal was estimated by the motion of the chest, whereas the cardiac signal was retrieved from the pulsatile activity at the level of right and left cheeks and forehead. Videos were recorded from 18 healthy volunteers in four sessions with different user-camera distances (i.e., 0.5 m and 1.0 m) and illumination conditions (i.e., natural and artificial light). For HR estimation, three approaches were investigated based on single or multi-ROI approaches. A commercially available multiparametric device was used to record reference respiratory signals and electrocardiogram (ECG). The results demonstrated that the multi-ROI approach outperforms the single-ROI approach providing temporal trends of both the vital parameters comparable to those provided by the reference, with a mean absolute error (MAE) consistently below 1 breaths·min−1 for fR in all the scenarios, and a MAE between 0.7 bpm and 6 bpm for HR estimation, whose values increase at higher distances.