Numerical Investigation of the Influence of Blade Radial Gap Flow on Axial Blood Pump Performance
- 1 January 2019
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (1) , 59-69
Abstract
The gaps between the blades and the shroud (or hub) of an axial blood pump affect the hydraulics, efficiency, and hemolytic performance. These gaps are critical parameters when a blood pump is manufactured. To evaluate the influence of blade gaps on axial blood pump performance, the flow characteristics inside an axial blood pump with different radial blade gaps were numerically simulated and analyzed with special attention paid to the hydraulic characteristics, gap flow, hydraulic efficiency, and hemolysis index (HI).In vitrohydraulic testing and particle image velocimetry testing were conducted to verify the numerical results. The simulation results showed that the efficiency and pressure rise decreased when the gap increased. The efficiency of the axial blood pump at design point decreased from 37.1% to 27.1% and the pressure rise decreased from 127.4 to 71.2 mm Hg when the gap increased from 0.1 to 0.3 mm. Return and vortex flows were present in the outlet guide vane channels when the gap was larger than 0.2 mm. The HI of the blood pump with a 0.1 mm gap was 1.5-fold greater than that with a 0.3 mm gap. The results illustrated poor hydraulic characteristics when the gap was larger than 0.15 mm and rapidly deteriorated hemolysis when the gap was larger than 0.1 mm. The numerical and experimental results demonstrated that the pressure rise, pump efficiency, and scalar shear stress decreased when the gap increased. The HI did not strictly decrease with gap increases. The preliminary results encourage the improvement of axial blood pump designs.Keywords
This publication has 24 references indexed in Scilit:
- Hydraulic and Hemodynamic Performance of a Minimally Invasive Intra-arterial Right Ventricular Assist DeviceThe International Journal of Artificial Organs, 2014
- Computational Fluid Dynamics-Based Hydraulic and Hemolytic Analyses of a Novel Left Ventricular Assist Blood PumpArtificial Organs, 2011
- Computational Characterization of Flow and Hemolytic Performance of the UltraMag Blood Pump for Circulatory SupportArtificial Organs, 2010
- Renal and Hepatic Function Improve in Advanced Heart Failure Patients During Continuous-Flow Support With the HeartMate II Left Ventricular Assist DeviceCirculation, 2009
- Design Optimization of an Axial Blood Pump With Computational Fluid DynamicsASAIO Journal, 2008
- Numerical Simulation of an Axial Blood PumpArtificial Organs, 2007
- A Validated Computational Fluid Dynamics Model to Estimate Hemolysis in a Rotary Blood PumpArtificial Organs, 2005
- Hematocrit, Volume Expander, Temperature, and Shear Rate Effects on Blood ViscosityAnesthesia & Analgesia, 2000
- Model for a General Mechanical Blood Damage PredictionArtificial Organs, 1995
- A Fluid Dynamic Analysis Using Flow Visualization of the Baylor/NASA Implantable Axial Flow Blood Pump for Design ImprovementArtificial Organs, 1995