Do “Anatomic” Distal Ulna Plating Systems Fit the Distal Ulna Without Causing Soft Tissue Impingement?
- 10 June 2020
- journal article
- research article
- Published by SAGE Publications in HAND
- Vol. 17 (3) , 506-511
Abstract
Background: Distal ulna fracture fixation plates commonly cause irritation, necessitating removal, due to the narrow area between the ulna articular cartilage and the extensor carpi ulnaris. This study defines the safe zone for plate application and determines whether wrist position affects risk of impingement. Methods: Four different distal ulna anatomic plates (Acumed, Medartis, Skeletal Dynamics, and Synthes) were applied to 12 cadaveric specimens. Safe zone size was measured in circumferential distance and angular arc. Impingement was examined in flexion and extension in neutral, pronation, and supination. Results: The distal ulna safe zone has dimensions of a 92° arc and perimeter circumference of 15 mm. Cumulative extensor carpi ulnaris (ECU) impingement occurred in 0% of the 6 simulated wrist/forearm positions for the Acumed plate, 22% for the Synthes plate, 31% for the Skeletal Dynamics plate, and 68% for the Medartis plate. Impingement was most common in supination. Likelihood of ECU impingement significantly decreased in the following order; Medartis > Skeletal Dynamics > Synthes > Acumed. Conclusion: The ECU tendon’s mobility can cause impingement on ulnarly placed distal ulna plates. Intra-operative testing should be performed in supination. Take home points regarding each plate from the 4 different manufacturers: contouring of Medartis plates, when placed ulnarly, is mandatory. The Acumed plate impinged the least but is not designed for far-distal fractures. The Synthes plate is least bulky but not suitable for proximal fractures. The Skeletal Dynamics plate appeared the most versatile with a reduced incidence of impingement compared to other ulnarly based plates.Keywords
This publication has 15 references indexed in Scilit:
- Anatomical study of the dorsal cutaneous branch of the ulnar nerve (DCBUN) and its clinical relevance in TFCC repairJournal of Plastic, Reconstructive & Aesthetic Surgery, 2016
- Hardware Location and Clinical Outcome in Ulna Shortening OsteotomyPlastic and Reconstructive Surgery - Global Open, 2015
- Anatomic Considerations for Plating of the Distal UlnaJournal of Wrist Surgery, 2015
- Soft Tissue Complications of Dorsal Versus Volar Plating for Ulnar Shortening OsteotomyThe Journal of Hand Surgery, 2015
- Distal Ulna FracturesThe Journal of Hand Surgery, 2014
- Outcomes of Ulnar Shortening Osteotomy Fixed With a Dynamic Compression SystemThe Journal of Hand Surgery, 2013
- THE DORSAL CUTANEOUS BRANCH OF THE ULNAR NERVE: AN ANATOMICAL STUDYHand Surgery, 2010
- The management of distal ulnar fractures in adults: a review of the literature and recommendations for treatmentStrategies in Trauma and Limb Reconstruction, 2008
- Plate Removal After Ulnar-Shortening OsteotomyThe Journal of Hand Surgery, 2005
- Ulna shortening osteotomy using a compression deviceThe Journal of Hand Surgery, 2003