Daniel A. Shaerf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daniel A. Shaerf has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Asif Saifuddin
Royal National Orthopaedic Hospital
3 shared publicationsBhupinder Mann
Royal National Orthopaedic Hospital
3 shared publications- John Andrew Skinner
Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK
3 shared publications - Maxim David Horwitz
Department of Hand Surgery, Chelsea and Westminster Hospital, London, UK
2 shared publications A Alva
London North West Healthcare NHS Trust , UK
1 shared publicationA. K. Malik
Stoke Mandeville Hospital, Buckinghamshire Healthcare NHS Trust, Mandeville Road, Aylesbury HP21 8AL, UK
1 shared publication
Latest Publications
- 10 June 2020
- Published by SAGE Publications in HAND
- Vol. 17 (3) , 506-511
Do “Anatomic” Distal Ulna Plating Systems Fit the Distal Ulna Without Causing Soft Tissue Impingement?
Background: Distal ulna fracture fixation plates commonly cause irritation, necessitating removal, due to the narrow area between the ulna articular cartilage and the extensor carpi ulnaris. This study defines the safe zone for plate application and determines whether wrist position affects risk of impingement. Methods: Four different distal ulna anatomic plates (Acumed, Medartis, Skeletal Dynamics, and Synthes) were applied to 12 cadaveric specimens. Safe zone size was measured in circumferential distance and angular arc. Impingement was examined in flexion and extension in neutral, pronation, and supination. Results: The distal ulna safe zone has dimensions of a 92° arc and perimeter circumference of 15 mm. Cumulative extensor carpi ulnaris (ECU) impingement occurred in 0% of the 6 simulated wrist/forearm positions for the Acumed plate, 22% for the Synthes plate, 31% for the Skeletal Dynamics plate, and 68% for the Medartis plate. Impingement was most common in supination. Likelihood of ECU impingement significantly decreased in the following order; Medartis > Skeletal Dynamics > Synthes > Acumed. Conclusion: The ECU tendon’s mobility can cause impingement on ulnarly placed distal ulna plates. Intra-operative testing should be performed in supination. Take home points regarding each plate from the 4 different manufacturers: contouring of Medartis plates, when placed ulnarly, is mandatory. The Acumed plate impinged the least but is not designed for far-distal fractures. The Synthes plate is least bulky but not suitable for proximal fractures. The Skeletal Dynamics plate appeared the most versatile with a reduced incidence of impingement compared to other ulnarly based plates.
- 10 June 2020
- Published by SAGE Publications in HAND
- Vol. 17 (3) , 506-511
Do “Anatomic” Distal Ulna Plating Systems Fit the Distal Ulna Without Causing Soft Tissue Impingement?
Background: Distal ulna fracture fixation plates commonly cause irritation, necessitating removal, due to the narrow area between the ulna articular cartilage and the extensor carpi ulnaris. This study defines the safe zone for plate application and determines whether wrist position affects risk of impingement. Methods: Four different distal ulna anatomic plates (Acumed, Medartis, Skeletal Dynamics, and Synthes) were applied to 12 cadaveric specimens. Safe zone size was measured in circumferential distance and angular arc. Impingement was examined in flexion and extension in neutral, pronation, and supination. Results: The distal ulna safe zone has dimensions of a 92° arc and perimeter circumference of 15 mm. Cumulative extensor carpi ulnaris (ECU) impingement occurred in 0% of the 6 simulated wrist/forearm positions for the Acumed plate, 22% for the Synthes plate, 31% for the Skeletal Dynamics plate, and 68% for the Medartis plate. Impingement was most common in supination. Likelihood of ECU impingement significantly decreased in the following order; Medartis > Skeletal Dynamics > Synthes > Acumed. Conclusion: The ECU tendon’s mobility can cause impingement on ulnarly placed distal ulna plates. Intra-operative testing should be performed in supination. Take home points regarding each plate from the 4 different manufacturers: contouring of Medartis plates, when placed ulnarly, is mandatory. The Acumed plate impinged the least but is not designed for far-distal fractures. The Synthes plate is least bulky but not suitable for proximal fractures. The Skeletal Dynamics plate appeared the most versatile with a reduced incidence of impingement compared to other ulnarly based plates.
- 19 August 2019
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 44 (10) , 1094-1096
Mechanical failure of the distal radius volar rim plate: a case report
- 19 August 2019
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 44 (10) , 1094-1096
Mechanical failure of the distal radius volar rim plate: a case report
- 7 April 2019
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 44 (6) , 652-654
Traumatic pseudoaneurysm of the ulnar artery treated with ultrasound guided thrombin injection
- 7 April 2019
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 44 (6) , 652-654
Traumatic pseudoaneurysm of the ulnar artery treated with ultrasound guided thrombin injection
- 11 April 2017
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 10 (2) , 114-120
Diagnosis, management and complications of distal humerus lateral condyle fractures in children
We review the diagnosis, evaluation and management of paediatric lateral condylar fractures. The complications of these fractures are also discussed, including the management of fracture non-union.
- 11 April 2017
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 10 (2) , 114-120
Diagnosis, management and complications of distal humerus lateral condyle fractures in children
We review the diagnosis, evaluation and management of paediatric lateral condylar fractures. The complications of these fractures are also discussed, including the management of fracture non-union.
- Open Access
- 1 September 2016
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 98 (7) , 520
Intraoperative assessment of flexor hallucis longus tendon integrity following hallux valgus correction
- 1 September 2016
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 98 (7) , 520
Open AccessIntraoperative assessment of flexor hallucis longus tendon integrity following hallux valgus correction
- Open Access
- 10 March 2014
- Published by Hindawi Limited in ISRN Anatomy
- Vol. 2014, 1-6
Neural Structures within Human Meniscofemoral Ligaments: A Cadaveric Study
Aim. To investigate the existence of neural structures within the meniscofemoral ligaments (MFLs) of the human knee. Methods. The MFLs from 8 human cadaveric knees were harvested. 5 μm sections were H&E-stained and examined under light microscopy. The harvested ligaments were then stained using an S100 monoclonal antibody utilising the ABC technique to detect neural components. Further examination was performed on 60–80 nm sections under electron microscopy. Results. Of the 8 knees, 6 were suitable for examination. From these both MFLs existed in 3, only anterior MFLs were present in 2, and an isolated posterior MFL existed in 1. Out of the 9 MFLs, 4 demonstrated neural structures on light and electron microscopy and this was confirmed with S100 staining. The ultrastructure of these neural components was morphologically similar to mechanoreceptors. Conclusion. Neural structures are present in MFLs near to their meniscal attachments. It is likely that the meniscofemoral ligaments contribute not only as passive secondary restraints to posterior draw but more importantly to proprioception and may therefore play an active role in providing a neurosensory feedback loop. This may be particularly important when the primary restraint has reduced function as in the posterior cruciate ligament—deficient human knee.
- 10 March 2014
- Published by Hindawi Limited in ISRN Anatomy
- Vol. 2014, 1-6
Open AccessNeural Structures within Human Meniscofemoral Ligaments: A Cadaveric Study
Aim. To investigate the existence of neural structures within the meniscofemoral ligaments (MFLs) of the human knee. Methods. The MFLs from 8 human cadaveric knees were harvested. 5 μm sections were H&E-stained and examined under light microscopy. The harvested ligaments were then stained using an S100 monoclonal antibody utilising the ABC technique to detect neural components. Further examination was performed on 60–80 nm sections under electron microscopy. Results. Of the 8 knees, 6 were suitable for examination. From these both MFLs existed in 3, only anterior MFLs were present in 2, and an isolated posterior MFL existed in 1. Out of the 9 MFLs, 4 demonstrated neural structures on light and electron microscopy and this was confirmed with S100 staining. The ultrastructure of these neural components was morphologically similar to mechanoreceptors. Conclusion. Neural structures are present in MFLs near to their meniscal attachments. It is likely that the meniscofemoral ligaments contribute not only as passive secondary restraints to posterior draw but more importantly to proprioception and may therefore play an active role in providing a neurosensory feedback loop. This may be particularly important when the primary restraint has reduced function as in the posterior cruciate ligament—deficient human knee.
- Open Access
- 1 January 2014
- Published by Baishideng Publishing Group Inc. in World Journal of Orthopedics
- Vol. 5 (1) , 23-29
Anterior cruciate ligament reconstruction best practice: A review of graft choice
Anterior cruciate ligament reconstruction best practice: A review of graft choice
- 1 January 2014
- Published by Baishideng Publishing Group Inc. in World Journal of Orthopedics
- Vol. 5 (1) , 23-29
Open AccessAnterior cruciate ligament reconstruction best practice: A review of graft choice
Anterior cruciate ligament reconstruction best practice: A review of graft choice
- 1 December 2012
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94 (12) , 1595-1597
Patient safety in orthopaedics
We summarise and highlight the safety concerns within the field of trauma and orthopaedic surgery with particular emphasis placed on current controversies and reforms within the United Kingdom National Health Service.
- 1 December 2012
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94 (12) , 1595-1597
Patient safety in orthopaedics
We summarise and highlight the safety concerns within the field of trauma and orthopaedic surgery with particular emphasis placed on current controversies and reforms within the United Kingdom National Health Service.
- 4 February 2012
- Published by SAGE Publications in HIP International
- Vol. 22 (2) , 129-136
Metal-On-Metal Bearings, Inflammatory Pseudotumours and Their Neurological Manifestations
Metal-on-metal bearings have become more popular for hip arthroplasty in younger patients in the last 15 years. We present a review of the neurological consequences relating to such bearing surfaces illustrated by an appropriate case report. The mechanisms of increased metal ion production and pseudotumour formation are discussed. If unexplained neurology, hip/groin pain or a localised mass around the hip are present with a metal bearing hip then urgent referral to a specialist orthopaedic surgeon is warranted for consideration of exchange arthroplasty.
- 4 February 2012
- Published by SAGE Publications in HIP International
- Vol. 22 (2) , 129-136
Metal-On-Metal Bearings, Inflammatory Pseudotumours and Their Neurological Manifestations
Metal-on-metal bearings have become more popular for hip arthroplasty in younger patients in the last 15 years. We present a review of the neurological consequences relating to such bearing surfaces illustrated by an appropriate case report. The mechanisms of increased metal ion production and pseudotumour formation are discussed. If unexplained neurology, hip/groin pain or a localised mass around the hip are present with a metal bearing hip then urgent referral to a specialist orthopaedic surgeon is warranted for consideration of exchange arthroplasty.
Triad in neuropathy from metal on metal hips
The review of the controversy surrounding the articular surface replacement hip prosthesis is timely.1 Such metal on metal prostheses have become popular over the past decade and are now present in many patients who visit their GP for other reasons. At our …
Triad in neuropathy from metal on metal hips
The review of the controversy surrounding the articular surface replacement hip prosthesis is timely.1 Such metal on metal prostheses have become popular over the past decade and are now present in many patients who visit their GP for other reasons. At our …