Validation of the Continuous Glucose Monitoring System (CGMS) by the Use of Two CGMS Simultaneously in Pregnant Women with Type 1 Diabetes Mellitus
- 1 October 2005
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 7 (5) , 699-706
Abstract
Background: In pregnant women with type 1 diabetes tight glycemic control reduces perinatal complications. Intensive observation of glucose profiles is essential in the achievement of tight glycemic control. The recent availability of the Continuous Glucose Monitoring System (CGMS®, Minimed, Sylmar, CA) creates the opportunity to obtain more complete glucose profiles. This study was aimed at evaluating the accuracy of the CGMS in pregnant women with type 1 diabetes. Methods: Five pregnant women with type 1 diabetes were asked to use two CGMS devices simultaneously. The simultaneously measured glucose levels were analyzed using the Pearson correlation, the mean absolute difference, and Bland–Altman analysis. Second, the percentage of concordance of paired data in the hypoglycemic, normoglycemic, or hyperglycemic range was calculated. Results: The correlation coefficient between simultaneously measured data was 0.94 (P < 0.001). The mean absolute difference was 1.1 ± 0.8 mmol/L. Bland–Altman analysis shows that 95% of the data pairs have a difference ≤1.74 mmol/L. Almost 80% of the data pairs could be classified in the same glucose range. In 81% of the non-concordant pairs, one glucose value was classified in the hypoglycemic range and one in the normoglycemic range. Conclusions: This study shows that the reproducibility of the CGMS in pregnant women with type 1 diabetes is adequate. This indicates that the CGMS is a useful tool in the management of type 1 diabetes in pregnant women. However, the CGMS should only be used as a supplementary method of daily glucose level measurement as a small degree of error, mainly in the hypoglycemic range, is present.Keywords
This publication has 14 references indexed in Scilit:
- Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System During HypoglycemiaDiabetes Care, 2004
- Performance assessment of the Medtronic‐MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjectsDiabetic Medicine, 2003
- Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditionsDiabetes & Metabolism, 2003
- Subcutaneous glucose sensor values closely parallel blood glucose during insulin‐induced hypoglycaemiaDiabetic Medicine, 2003
- Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin AnalogsDiabetes Care, 2003
- Spurious Reporting of Nocturnal Hypoglycemia by CGMS in Patients With Tightly Controlled Type 1 DiabetesDiabetes Care, 2002
- Reproducibility of Glucose Measurements Using the Glucose SensorDiabetes Care, 2002
- The Effect of Glycemic Control in the Pre-Conception Period and Early Pregnancy on Birth Weight in Women With IDDMDiabetes Care, 1998
- Pre-Conception Care of Diabetes, Congenital Malformations, and Spontaneous AbortionsDiabetes Care, 1996
- Pregnancy outcome in patients with insulin-dependent diabetes mellitus with preconceptional diabetic control: A comparative studyAmerican Journal of Obstetrics and Gynecology, 1986