Study on Restoring Force Model of Plate-Reinforced Composite Coupling Beam with Small Span-to-Depth Ratio
Open Access
Abstract
Coupling beams are critical connecting components in coupled shear wall systems and core tube structures. At the same time, they play an important role when the structure is subjected to an earthquake. Plate-reinforced composite (PRC) coupling beams exhibit superior comprehensive performance in terms of bearing capacity, deformation performance, energy dissipation capacity, and construction efficiency. However, research on PRC coupling beams remains limited both domestically and internationally. To better describe the structural response of steel plate–concrete composite coupling beams, this study collected existing experimental data. The beams had a small span-to-depth ratio. The loading was cyclic. The study normalized the skeleton curves of each specimen. The span-to-depth ratio ranged from 0.9 to 2.5. The plate ratio ranged from 3% to 5%. For these beams, preliminary skeleton curve fitting equations are proposed. The equations are based on existing data. The equations apply to two types of composite coupling beams. One type uses a steel plate and ordinary concrete. The other type uses a steel plate and fiber concrete. These equations are derived using a trilinear model and linear fitting tools. Furthermore, restoring force models for steel plate–conventional concrete and steel plate–fiber concrete composite coupling beams with a small span-to-depth ratio are proposed. Comparative analysis shows that each model captures the hysteretic response of PRC coupling beams with acceptable accuracy in the elastic and decline phases, while the elastic–plastic stage is suitable only for trend prediction. It should be noted that the proposed models are preliminary engineering approximations primarily applicable within the following ranges: a span-to-depth ratio of 0.9~2.5, a plate ratio of 3~5%, concrete strength of C30~C50, a longitudinal reinforcement ratio of 0.86~2.23%, a stirrup ratio of 0.56~0.63%, and a steel plate thickness of 6~10 mm. For configurations significantly outside these ranges, additional experimental validation is required.Keywords
Funding Information
- Natural Science Foundation of Ningxia Province (2023AAC03317)
- Special Fund Project for Basic Scientific Research of Central Universities of North Minzu University (2025XYZTM01)
- Natural Science Basic Research Program in Shaanxi Province of China (2025JC-YBMS-449)
This publication has 16 references indexed in Scilit:
- Shear performance of RC beams employing thin-layer ultra-high-ductile concrete permanent formwork (UHDC-PF): Experimental, numerical and theoretical investigationsStructures, 2026
- Restoring force model for steel beam to CFST/HSS column joints with a reinforced concrete slabJournal of Building Engineering, 2023
- A unified section-based restoring force model for reinforced concrete coupling beams based on the XGBoost model: Establishment, validation and applicationJournal of Building Engineering, 2023
- Seismic behaviour of plate-reinforced composite coupling beams with RC slabsSoil Dynamics and Earthquake Engineering, 2023
- Seismic performance and numerical analysis of steel plate-fiber reinforced concrete composite coupling beamsStructures, 2022
- Experimental and numerical study of PRC coupling beams with low span-to-depth ratioJournal of Constructional Steel Research, 2019
- Seismic performance of steel plate reinforced high toughness concrete coupling beams with different steel plate ratiosComposites Part B: Engineering, 2019
- An analytical approach to predict shear capacity of steel fiber reinforced concrete coupling beams with small span-depth ratioEngineering Structures, 2018
- Effectiveness of high performance fiber-reinforced cement composites in slender coupling beamsConstruction and Building Materials, 2014
- Effects of shear connectors on plate-reinforced composite coupling beams of short and medium-length spansJournal of Constructional Steel Research, 2006