Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring
Open Access
- 1 December 2014
- journal article
- research article
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 13 (6) , 517-528
Abstract
The integrated use of optical technologies for patient monitoring is addressed in the framework of time-resolved treatment delivery for scanned ion beam therapy. A software application has been designed to provide the therapy control system (TCS) with a continuous geometrical feedback by processing the external surrogates tridimensional data, detected in real-time via optical tracking. Conventional procedures for phase-based respiratory phase detection were implemented, as well as the interface to patient specific correlation models, in order to estimate internal tumor motion from surface markers. In this paper, particular attention is dedicated to the quantification of time delays resulting from system integration and its compensation by means of polynomial interpolation in the time domain. Dedicated tests to assess the separate delay contributions due to optical signal processing, digital data transfer to the TCS and passive beam energy modulation actuation have been performed. We report the system technological commissioning activities reporting dose distribution errors in a phantom study, where the treatment of a lung lesion was simulated, with both lateral and range beam position compensation. The zero-delay systems integration with a specific active scanning delivery machine was achieved by tuning the amount of time prediction applied to lateral (14.61 ± 0.98 ms) and depth (34.1 ± 6.29 ms) beam position correction signals, featuring sub-millimeter accuracy in forward estimation. Direct optical target observation and motion phase (MPh) based tumor motion discretization strategies were tested, resulting in −0.3(2.3)% and −1.2(9.3)% median (IQR) percentual relative dose difference with respect to static irradiation, respectively. Results confirm the technical feasibility of the implemented strategy towards 4D treatment delivery, with negligible percentual dose deviations with respect to static irradiation.Keywords
This publication has 43 references indexed in Scilit:
- Scanned carbon beam irradiation of moving films: comparison of measured and calculated responseRadiation Oncology, 2012
- Moving target irradiation with fast rescanning and gating in particle therapyMedical Physics, 2010
- Dosimetric precision of an ion beam tracking systemRadiation Oncology, 2010
- Speckle tracking in a phantom and feature-based tracking in liver in the presence of respiratory motion using 4D ultrasoundPhysics in Medicine & Biology, 2010
- Do We Have Enough Evidence to Implement Particle Therapy as Standard Treatment in Lung Cancer? A Systematic Literature ReviewThe Oncologist, 2010
- Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beamsPhysics in Medicine & Biology, 2009
- Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motionsPhysics in Medicine & Biology, 2008
- 4D treatment planning for scanned ion beamsRadiation Oncology, 2007
- Design study of a raster scanning system for moving target irradiation in heavy‐ion radiotherapyMedical Physics, 2007
- Simulations to design an online motion compensation system for scanned particle beamsPhysics in Medicine & Biology, 2006