In vitro evaluation of the effects of intraluminal thrombus on abdominal aortic aneurysm wall dynamics
Authors:
- Florentina EneFEFlorentina Ene
- Carine GachonCGCarine Gachon
- Patrick DelassusPDPatrick Delassus
- Ronan CarrollRCRonan Carroll
- Florian StefanovFSFlorian Stefanov
- Padraig O’fLynnPOPadraig O’fLynn
- Liam MorrisLMLiam Morris
- 7 April 2011
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 33 (8) , 957-966
Abstract
The optimum time to treat abdominal aortic aneurysms (AAAs) still remains an uncertain issue. The decision to intervene does not take in account the effects that wall curvature, intraluminal thrombus (ILT) properties and thickness have on rupture. The role of ILT in aneurysm dynamics and rupture has been controversial. In vitro testing of four silicone AAA models incorporating the ILT and aortic bifurcation was studied under physiological conditions. Pressures (P) and diameters (D) were analysed for models with and without ILT at different locations. The diametral strain, compliance and P/D curves were influenced by the presence, elastic stiffness and thickness of the ILT. In this case, the inclusion of ILT reduced the lumen area by 77% that resulted in a 0.5-81% reduction in compliance depending on ILT properties. With an increase in ILT stiffness from 0.05 to 0.2 MPa, the compliance was reduced by 81%. In the region of maximum diameter, there was a reduction of diametral strain and compliance except for the softer ILT which was more compliant throughout the proximal region. The shifting of the maximum diametral strain and compliance to the proximal neck was pronounced by an increase in ILT stiffness, thus creating a possible rupture site.Keywords
This publication has 39 references indexed in Scilit:
- Impact of calcification and intraluminal thrombus on the computed wall stresses of abdominal aortic aneurysmJournal of Vascular Surgery, 2008
- Effect of Variation in Intraluminal Thrombus Constitutive Properties on Abdominal Aortic Aneurysm Wall StressAnnals of Biomedical Engineering, 2003
- Effect of intraluminal thrombus on wall stress in patient-specific models of abdominal aortic aneurysmJournal of Vascular Surgery, 2002
- Mechanical Properties and Microstructure of Intraluminal Thrombus From Abdominal Aortic AneurysmJournal of Biomechanical Engineering, 2001
- Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: Experimental characterisation and structural static computational analysisEuropean Journal of Vascular and Endovascular Surgery, 1998
- Effect of intraluminal thrombus on abdominal aortic aneurysm wall stressJournal of Vascular Surgery, 1997
- Potential influence of intraluminal thrombus on abdominal aortic aneurysm as assessed by a new non-invasive methodCardiovascular Surgery, 1996
- Intraluminal thrombus predicts rupture of an abdominal aortic aneurysmJournal of Vascular Surgery, 1996
- Biomechanical factors in abdominal aortic aneurysm ruptureEuropean Journal of Vascular Surgery, 1993
- Ultrasonic evaluation of abdominal aortic thrombus.Journal of Ultrasound in Medicine, 1982