Florentina Ene
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florentina Ene has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Carine Gachon
1 shared publication- Florian Stefanov
Galway Medical Technologies Centre, Department of Mechanical and Industrial Engineering, Galway Mayo Institute of Technology, Galway, Ireland
1 shared publication Liam Morris
1 shared publicationPadraig O’fLynn
1 shared publicationPatrick Delassus
1 shared publicationRonan Carroll
1 shared publication
Latest Publications
- 7 April 2011
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 33 (8) , 957-966
In vitro evaluation of the effects of intraluminal thrombus on abdominal aortic aneurysm wall dynamics
The optimum time to treat abdominal aortic aneurysms (AAAs) still remains an uncertain issue. The decision to intervene does not take in account the effects that wall curvature, intraluminal thrombus (ILT) properties and thickness have on rupture. The role of ILT in aneurysm dynamics and rupture has been controversial. In vitro testing of four silicone AAA models incorporating the ILT and aortic bifurcation was studied under physiological conditions. Pressures (P) and diameters (D) were analysed for models with and without ILT at different locations. The diametral strain, compliance and P/D curves were influenced by the presence, elastic stiffness and thickness of the ILT. In this case, the inclusion of ILT reduced the lumen area by 77% that resulted in a 0.5-81% reduction in compliance depending on ILT properties. With an increase in ILT stiffness from 0.05 to 0.2 MPa, the compliance was reduced by 81%. In the region of maximum diameter, there was a reduction of diametral strain and compliance except for the softer ILT which was more compliant throughout the proximal region. The shifting of the maximum diametral strain and compliance to the proximal neck was pronounced by an increase in ILT stiffness, thus creating a possible rupture site.
- 7 April 2011
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 33 (8) , 957-966
In vitro evaluation of the effects of intraluminal thrombus on abdominal aortic aneurysm wall dynamics
The optimum time to treat abdominal aortic aneurysms (AAAs) still remains an uncertain issue. The decision to intervene does not take in account the effects that wall curvature, intraluminal thrombus (ILT) properties and thickness have on rupture. The role of ILT in aneurysm dynamics and rupture has been controversial. In vitro testing of four silicone AAA models incorporating the ILT and aortic bifurcation was studied under physiological conditions. Pressures (P) and diameters (D) were analysed for models with and without ILT at different locations. The diametral strain, compliance and P/D curves were influenced by the presence, elastic stiffness and thickness of the ILT. In this case, the inclusion of ILT reduced the lumen area by 77% that resulted in a 0.5-81% reduction in compliance depending on ILT properties. With an increase in ILT stiffness from 0.05 to 0.2 MPa, the compliance was reduced by 81%. In the region of maximum diameter, there was a reduction of diametral strain and compliance except for the softer ILT which was more compliant throughout the proximal region. The shifting of the maximum diametral strain and compliance to the proximal neck was pronounced by an increase in ILT stiffness, thus creating a possible rupture site.