An Optical Micro/Nano Fiber Sensor for Monitoring Respiration
Open Access
Abstract
In the field of clinical medicine, the real-time monitoring of carbon dioxide (CO2) gas exhaled by the human body is of great significance. At present, the detection devices on the market mainly work by sucking a small amount of gas from the nasal cavity into the detection device, and they present some problems such as overly long sampling tubes, easy blockage or distortion, and an abnormal gas dispersion. In this paper, a micro/nano optical fiber sensor that can directly detect respiration is proposed and is characterized by the relative change in CO2 concentration. The measurement is achieved by using the principle of high evanescent field absorption, and the operating band is 2.004 μm. The sensing effects of micro/nano fibers with different diameters are compared, and the experiment proves that a micro/nano fiber with a diameter of 1 μm can be measured. The light intensity change over 30 s was measured, and the breathing rate was 10–11 times/min. The sensor can achieve a rapid real-time response to CO2 gas detection and is small in size, low-cost, and easy to replace. It has a great application potential in clinical scenarios such as in gastrointestinal endoscopes that require real-time monitoring of human respiration.Keywords
Funding Information
- National Natural Science Foundation of China (62027825, 20220101130JC, ZR2019MC069, D21009)
- Natural Science Foundation of Jilin Province (62027825, 20220101130JC, ZR2019MC069, D21009)
- Natural Science Foundation of Shandong Province (62027825, 20220101130JC, ZR2019MC069, D21009)
- 111 project of China (62027825, 20220101130JC, ZR2019MC069, D21009)
This publication has 24 references indexed in Scilit:
- Mid-Infrared Gas Detection Using a Chalcogenide Suspended-Core FiberJournal of Lightwave Technology, 2019
- Laryngeal Mask Airway Versus Other Airway Devices for Anesthesia in Children With an Upper Respiratory Tract Infection: A Systematic Review and Meta-analysis of Respiratory ComplicationsAnesthesia & Analgesia, 2018
- Room-temperature-operated organic-based acetone gas sensor for breath analysisSensors and Actuators B: Chemical, 2018
- Zeolite membranes for highly selective formaldehyde sensorsSensors and Actuators B: Chemical, 2018
- Diagnosis and Classification of 17 Diseases from 1404 Subjects via Pattern Analysis of Exhaled MoleculesACS Nano, 2016
- HITRANonline: An online interface and the flexible representation of spectroscopic data in the HITRAN databaseJournal of Quantitative Spectroscopy and Radiative Transfer, 2016
- Monitoring breath markers under controlled conditionsJournal of Breath Research, 2015
- A mainstream monitoring system for respiratory CO2 concentration and gasflowJournal of Clinical Monitoring and Computing, 2015
- The HITRAN 2008 molecular spectroscopic databaseJournal of Quantitative Spectroscopy and Radiative Transfer, 2009
- Infrared Measurement of Carbon Dioxide in the Human Breath: “Breathe-Through” Devices from Tyndall to the Present DayAnesthesia & Analgesia, 2008