Tuo Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tuo Chen has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Mingyu Li
School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
7 shared publications - Shiya Zhang
Department of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
4 shared publications - Jian-Jun He
Zhejiang University
3 shared publications Yuxia Song
3 shared publications- Bingfeng Liu
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing 100015, China
2 shared publications - Han Jia
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing 100015, China
2 shared publications
Latest Publications
- Open Access
Phase-Invariant Thickness Metrology for Subwavelength Gratings via Zero-Crossing Analysis
Subwavelength gratings (SWGs) exhibit optical responses that are highly sensitive to structural parameters, where the etching depth is a critical parameter determining device performance but remains challenging to characterize accurately. In this work, a robust thickness retrieval method based on Variational mode decomposition (VMD)-assisted zero-crossing phase analysis is proposed. By extracting the oscillatory component containing thickness-dependent phase information from the reflection spectrum and exploiting the phase invariance of zero-crossing positions, the proposed method enables thickness retrieval with reduced sensitivity to spectral intensity distortions. Combined with second-order effective medium theory (EMT) and the Sellmeier dispersion model, the physical thickness is retrieved through nonlinear phase matching. Simulation results demonstrate that the equivalent medium model achieves relative deviations below 0.7%. For SWGs with a nominal etching depth of 3 μm, the proposed method maintains thickness retrieval errors of 0.54–0.66%, with a coefficient of variation (CoV) below 0.03% under 20% Gaussian noise. Furthermore, under severe baseline drift and amplitude modulation, the proposed method achieves a retrieved thickness of 2.982 ± 0.005 μm, significantly outperforming conventional peak-fitting methods. This approach provides an effective solution for high-precision characterization of subwavelength optical structures.
Open AccessPhase-Invariant Thickness Metrology for Subwavelength Gratings via Zero-Crossing Analysis
Subwavelength gratings (SWGs) exhibit optical responses that are highly sensitive to structural parameters, where the etching depth is a critical parameter determining device performance but remains challenging to characterize accurately. In this work, a robust thickness retrieval method based on Variational mode decomposition (VMD)-assisted zero-crossing phase analysis is proposed. By extracting the oscillatory component containing thickness-dependent phase information from the reflection spectrum and exploiting the phase invariance of zero-crossing positions, the proposed method enables thickness retrieval with reduced sensitivity to spectral intensity distortions. Combined with second-order effective medium theory (EMT) and the Sellmeier dispersion model, the physical thickness is retrieved through nonlinear phase matching. Simulation results demonstrate that the equivalent medium model achieves relative deviations below 0.7%. For SWGs with a nominal etching depth of 3 μm, the proposed method maintains thickness retrieval errors of 0.54–0.66%, with a coefficient of variation (CoV) below 0.03% under 20% Gaussian noise. Furthermore, under severe baseline drift and amplitude modulation, the proposed method achieves a retrieved thickness of 2.982 ± 0.005 μm, significantly outperforming conventional peak-fitting methods. This approach provides an effective solution for high-precision characterization of subwavelength optical structures.
- Open Access
Ultrafast Fiber Lasers in the 2 μm Band: Mode-Locking Techniques, Performance Advances and Applications
Ultrafast fiber lasers operating near 2 μm have emerged as a critical platform for advancing mid-infrared photonics due to their narrow pulse durations, high peak powers, and broad tunability. These sources exploit the rich energy-level structures of Tm3+ and Ho3+ doped fibers and reside within an atmospheric transmission window, enabling applications spanning nonlinear microscopy, precision micromachining, optical frequency metrology, biophotonics, and free-space optical communication. Recent progress in low-loss fiber fabrication, dispersion-engineered cavity design, and mode-locking technologies has significantly expanded the performance boundaries of 2 μm ultrafast fiber lasers. This review systematically examines the underlying pulse-formation mechanisms and categorizes state-of-the-art mode-locking approaches. Representative laser architectures are compared with respect to pulse duration, energy scalability, repetition-rate enhancement, spectral characteristics, and environmental stability. Key application pathways in high-resolution spectroscopy, biomedical diagnostics, and mid-IR supercontinuum generation are highlighted. Finally, the remaining challenges and prospective research directions are discussed to inform the development of next-generation ultrafast photonic sources in the 2 μm band.
Open AccessUltrafast Fiber Lasers in the 2 μm Band: Mode-Locking Techniques, Performance Advances and Applications
Ultrafast fiber lasers operating near 2 μm have emerged as a critical platform for advancing mid-infrared photonics due to their narrow pulse durations, high peak powers, and broad tunability. These sources exploit the rich energy-level structures of Tm3+ and Ho3+ doped fibers and reside within an atmospheric transmission window, enabling applications spanning nonlinear microscopy, precision micromachining, optical frequency metrology, biophotonics, and free-space optical communication. Recent progress in low-loss fiber fabrication, dispersion-engineered cavity design, and mode-locking technologies has significantly expanded the performance boundaries of 2 μm ultrafast fiber lasers. This review systematically examines the underlying pulse-formation mechanisms and categorizes state-of-the-art mode-locking approaches. Representative laser architectures are compared with respect to pulse duration, energy scalability, repetition-rate enhancement, spectral characteristics, and environmental stability. Key application pathways in high-resolution spectroscopy, biomedical diagnostics, and mid-IR supercontinuum generation are highlighted. Finally, the remaining challenges and prospective research directions are discussed to inform the development of next-generation ultrafast photonic sources in the 2 μm band.
- Open Access
Transmission Characteristics of 80 Gbit/s Nyquist-DWDM System in Atmospheric Turbulence
We experimentally demonstrate an 80 Gbit/s Nyquist-dense wavelength division multiplexed (Nyquist-DWDM) transmission system operating in a simulated atmospheric turbulence channel. The system utilizes eight wavelength-tunable lasers with 100 GHz spacing, modulated by cascaded Mach–Zehnder modulators, to generate phase-locked Nyquist pulse sequences with a 10 GHz repetition rate and a temporal width of 66.7 ps. Each channel is synchronously modulated with a 10 Gbit/s pseudo-random bit sequence (PRBS) and transmitted through controlled weak turbulence conditions generated by a temperature-gradient convection chamber. Experimental measurements reveal that, as the turbulence intensity increases from to , the signal-to-noise ratio (SNR) of the edge channel (C29) and central channel (C33) decreases by approximately 6.5 dB while maintaining stable Nyquist waveform profiles and inter-channel orthogonality. At a forward-error-correction (FEC) threshold of , the minimum receiver sensitivity is −17.66 dBm, corresponding to power penalties below 5 dB relative to the back-to-back condition. The consistent SNR difference (<2 dB) between adjacent channels confirms uniform power distribution and low inter-channel crosstalk under turbulence. These findings verify that Nyquist pulse shaping substantially mitigates phase distortion and scintillation effects, demonstrating the feasibility of high-capacity DWDM free-space optical (FSO) systems with enhanced spectral efficiency and turbulence resilience. The proposed configuration provides a scalable foundation for future multi-wavelength FSO links and hybrid fiber-wireless optical networks.Open AccessTransmission Characteristics of 80 Gbit/s Nyquist-DWDM System in Atmospheric Turbulence
We experimentally demonstrate an 80 Gbit/s Nyquist-dense wavelength division multiplexed (Nyquist-DWDM) transmission system operating in a simulated atmospheric turbulence channel. The system utilizes eight wavelength-tunable lasers with 100 GHz spacing, modulated by cascaded Mach–Zehnder modulators, to generate phase-locked Nyquist pulse sequences with a 10 GHz repetition rate and a temporal width of 66.7 ps. Each channel is synchronously modulated with a 10 Gbit/s pseudo-random bit sequence (PRBS) and transmitted through controlled weak turbulence conditions generated by a temperature-gradient convection chamber. Experimental measurements reveal that, as the turbulence intensity increases from to , the signal-to-noise ratio (SNR) of the edge channel (C29) and central channel (C33) decreases by approximately 6.5 dB while maintaining stable Nyquist waveform profiles and inter-channel orthogonality. At a forward-error-correction (FEC) threshold of , the minimum receiver sensitivity is −17.66 dBm, corresponding to power penalties below 5 dB relative to the back-to-back condition. The consistent SNR difference (<2 dB) between adjacent channels confirms uniform power distribution and low inter-channel crosstalk under turbulence. These findings verify that Nyquist pulse shaping substantially mitigates phase distortion and scintillation effects, demonstrating the feasibility of high-capacity DWDM free-space optical (FSO) systems with enhanced spectral efficiency and turbulence resilience. The proposed configuration provides a scalable foundation for future multi-wavelength FSO links and hybrid fiber-wireless optical networks. - 19 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (6) , 14129-14141
Wavelength locking and parameter calibration method for V-cavity tunable modules
In modern optical communication networks, traditional wavelength control technologies face limitations such as temperature sensitivity and complex mechanical structures. A wavelength locking scheme for V-cavity tunable laser optical modules with a transmission rate of 25Gbps is proposed in this paper. By integrating a monitoring photodiode (MPD) within the optical module and implementing a temperature current control algorithm, efficient wavelength locking is achieved without the need for additional optical components or external detection devices. The scheme utilizes the MPD to monitor the transmitted and received optical power in real-time and optimizes wavelength tuning by adjusting the temperature-control current (TCC). Through curve fitting and the Newton method, rapid wavelength convergence is ensured to match the peak power of the communication channel. Experimental results demonstrate that the optimal TCC range for 15 sets of measurements is between 47 mA and 53 mA, with a mean difference of 0.012 mA and a standard deviation of 0.0183 mA between the ideal and actual operating points, verifying the stability and low wavelength drift characteristics of the proposed scheme. This scheme has the potential to simplify system structures and enhance transmission performance, making it applicable to high-density wavelength-division multiplexing systems and other optical communication scenarios.
- 19 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (6) , 14129-14141
Wavelength locking and parameter calibration method for V-cavity tunable modules
In modern optical communication networks, traditional wavelength control technologies face limitations such as temperature sensitivity and complex mechanical structures. A wavelength locking scheme for V-cavity tunable laser optical modules with a transmission rate of 25Gbps is proposed in this paper. By integrating a monitoring photodiode (MPD) within the optical module and implementing a temperature current control algorithm, efficient wavelength locking is achieved without the need for additional optical components or external detection devices. The scheme utilizes the MPD to monitor the transmitted and received optical power in real-time and optimizes wavelength tuning by adjusting the temperature-control current (TCC). Through curve fitting and the Newton method, rapid wavelength convergence is ensured to match the peak power of the communication channel. Experimental results demonstrate that the optimal TCC range for 15 sets of measurements is between 47 mA and 53 mA, with a mean difference of 0.012 mA and a standard deviation of 0.0183 mA between the ideal and actual operating points, verifying the stability and low wavelength drift characteristics of the proposed scheme. This scheme has the potential to simplify system structures and enhance transmission performance, making it applicable to high-density wavelength-division multiplexing systems and other optical communication scenarios.
- Open Access
- 6 March 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (5) , 408
Research on Wet Etching Techniques for GaInAs/AlInAs/InP Superlattices in Quantum Cascade Laser Fabrication
Wet etching is the mainstream fabrication method for single-bar quantum cascade lasers (QCLs). Different etching solutions result in varying etching effects on III-V semiconductor materials. In this study, an efficient and nearly ideal etching solution ratio was proposed for simultaneously etching both InP and GaInAs/AlInAs, and the surface chemical reactions induced by each component of the etching solution during the process were investigated. Using univariate and single-component experiments, coupled with various characterization techniques such as atomic force microscopy (AFM), stylus profilometer, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), we found that the ratio of HBr to hydrogen peroxide significantly determines the etching rate, while the ratio of HCl to hydrogen peroxide affects the interface roughness. The aim of this study was to provide a comprehensive understanding of the effects of different etching solution components, thereby enhancing the understanding of the wet etching process for InP/GaInAs/AlInAs materials. These findings offer valuable insights into efficient QCL fabrication processes and contribute to the advancement of the field.
- 6 March 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (5) , 408
Open AccessResearch on Wet Etching Techniques for GaInAs/AlInAs/InP Superlattices in Quantum Cascade Laser Fabrication
Wet etching is the mainstream fabrication method for single-bar quantum cascade lasers (QCLs). Different etching solutions result in varying etching effects on III-V semiconductor materials. In this study, an efficient and nearly ideal etching solution ratio was proposed for simultaneously etching both InP and GaInAs/AlInAs, and the surface chemical reactions induced by each component of the etching solution during the process were investigated. Using univariate and single-component experiments, coupled with various characterization techniques such as atomic force microscopy (AFM), stylus profilometer, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), we found that the ratio of HBr to hydrogen peroxide significantly determines the etching rate, while the ratio of HCl to hydrogen peroxide affects the interface roughness. The aim of this study was to provide a comprehensive understanding of the effects of different etching solution components, thereby enhancing the understanding of the wet etching process for InP/GaInAs/AlInAs materials. These findings offer valuable insights into efficient QCL fabrication processes and contribute to the advancement of the field.
- Open Access
- 3 March 2025
- Published by MDPI AG in Preprints.org
Research on Wet Etching Techniques for GaInAs/AlInAs/InP Superlattices in Quantum Cascade Laser Fabrication
Wet etching is the mainstream fabrication method for single-bar quantum cascade lasers (QCLs). Different etching solutions result in varying etching effects on III-V semiconductor materials. In this study, an efficient and nearly ideal etching solution ratio was proposed for simultaneously etching both InP and GaInAs/AlInAs, and the surface chemical reactions induced by each component of the etching solution during the process were investigated. Using univariate and single-component experiments, coupled with various characterization techniques such as atomic force microscopy (AFM), stylus profilometer, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), we found that the ratio of HBr to hydrogen peroxide significantly determines the etching rate, while the ratio of HCl to hydrogen peroxide affects the interface roughness. The aim of this study was to provide a comprehensive understanding of the effects of different etching solution components, thereby enhancing the understanding of the wet etching process for InP/GaInAs/AlInAs materials. These findings offer valuable insights for efficient QCL fabrication processes and contribute to the advancement of the field.
- 3 March 2025
- Published by MDPI AG in Preprints.org
Open AccessResearch on Wet Etching Techniques for GaInAs/AlInAs/InP Superlattices in Quantum Cascade Laser Fabrication
Wet etching is the mainstream fabrication method for single-bar quantum cascade lasers (QCLs). Different etching solutions result in varying etching effects on III-V semiconductor materials. In this study, an efficient and nearly ideal etching solution ratio was proposed for simultaneously etching both InP and GaInAs/AlInAs, and the surface chemical reactions induced by each component of the etching solution during the process were investigated. Using univariate and single-component experiments, coupled with various characterization techniques such as atomic force microscopy (AFM), stylus profilometer, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), we found that the ratio of HBr to hydrogen peroxide significantly determines the etching rate, while the ratio of HCl to hydrogen peroxide affects the interface roughness. The aim of this study was to provide a comprehensive understanding of the effects of different etching solution components, thereby enhancing the understanding of the wet etching process for InP/GaInAs/AlInAs materials. These findings offer valuable insights for efficient QCL fabrication processes and contribute to the advancement of the field.
- 10 January 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (1) , 1359-1370
Effect of NaCl on the modulation of LPFG double peak by PDDA/PSS nanomembrane
In this paper, poly(diallyldimethylammonium chloride)(PDDA)/poly(sodium styrene sulfonate)(PSS) nanomembranes were deposited on the surface of long-period fiber gratings (LPFG) using the electrostatic layer-by-layer (LBL) assembly method, and the effect of NaCl on the modulation of LPFG double peaks by PDDA/PSS nanomembranes was investigated. The principle behind the emergence of double peaks was first explored using coupled mode theory, revealing that changes in the mode effective refractive index(RI) occur as the number of nanomembrane layers increases. The experimental results showed that under the conditions of PDDA with NaCl/PSS without NaCl and PDDA without NaCl/PSS with NaCl, double peaks do not appear in the spectra of LPFG as the number of thin film layers increases. In contrast, highly sensitive double peaks appear in the spectra of LPFG when both PDDA and PSS contain NaCl. Additionally, the range of these double peaks was explored. It was shown that the sensitivity of LPFG to the nanomembrane reached a maximum at 79-81 bilayers, with a sensitivity of 37.8 nm/bilayer, and the appearance of double peaks was consistent with the theoretical simulation. The findings of this study will be applied to the modification of LPFG surface biofunctional membranes and the highly sensitive detection of biochemical substances.
- 10 January 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (1) , 1359-1370
Effect of NaCl on the modulation of LPFG double peak by PDDA/PSS nanomembrane
In this paper, poly(diallyldimethylammonium chloride)(PDDA)/poly(sodium styrene sulfonate)(PSS) nanomembranes were deposited on the surface of long-period fiber gratings (LPFG) using the electrostatic layer-by-layer (LBL) assembly method, and the effect of NaCl on the modulation of LPFG double peaks by PDDA/PSS nanomembranes was investigated. The principle behind the emergence of double peaks was first explored using coupled mode theory, revealing that changes in the mode effective refractive index(RI) occur as the number of nanomembrane layers increases. The experimental results showed that under the conditions of PDDA with NaCl/PSS without NaCl and PDDA without NaCl/PSS with NaCl, double peaks do not appear in the spectra of LPFG as the number of thin film layers increases. In contrast, highly sensitive double peaks appear in the spectra of LPFG when both PDDA and PSS contain NaCl. Additionally, the range of these double peaks was explored. It was shown that the sensitivity of LPFG to the nanomembrane reached a maximum at 79-81 bilayers, with a sensitivity of 37.8 nm/bilayer, and the appearance of double peaks was consistent with the theoretical simulation. The findings of this study will be applied to the modification of LPFG surface biofunctional membranes and the highly sensitive detection of biochemical substances.
- Open Access
- 30 November 2023
- Published by Elsevier in Results in Physics
- Vol. 56
High single-mode selectivity V-cavity tunable semiconductor laser based on GaAs
- 30 November 2023
- Published by Elsevier in Results in Physics
- Vol. 56
Open AccessHigh single-mode selectivity V-cavity tunable semiconductor laser based on GaAs
- Open Access
An Optical Micro/Nano Fiber Sensor for Monitoring Respiration
In the field of clinical medicine, the real-time monitoring of carbon dioxide (CO2) gas exhaled by the human body is of great significance. At present, the detection devices on the market mainly work by sucking a small amount of gas from the nasal cavity into the detection device, and they present some problems such as overly long sampling tubes, easy blockage or distortion, and an abnormal gas dispersion. In this paper, a micro/nano optical fiber sensor that can directly detect respiration is proposed and is characterized by the relative change in CO2 concentration. The measurement is achieved by using the principle of high evanescent field absorption, and the operating band is 2.004 μm. The sensing effects of micro/nano fibers with different diameters are compared, and the experiment proves that a micro/nano fiber with a diameter of 1 μm can be measured. The light intensity change over 30 s was measured, and the breathing rate was 10–11 times/min. The sensor can achieve a rapid real-time response to CO2 gas detection and is small in size, low-cost, and easy to replace. It has a great application potential in clinical scenarios such as in gastrointestinal endoscopes that require real-time monitoring of human respiration.
Open AccessAn Optical Micro/Nano Fiber Sensor for Monitoring Respiration
In the field of clinical medicine, the real-time monitoring of carbon dioxide (CO2) gas exhaled by the human body is of great significance. At present, the detection devices on the market mainly work by sucking a small amount of gas from the nasal cavity into the detection device, and they present some problems such as overly long sampling tubes, easy blockage or distortion, and an abnormal gas dispersion. In this paper, a micro/nano optical fiber sensor that can directly detect respiration is proposed and is characterized by the relative change in CO2 concentration. The measurement is achieved by using the principle of high evanescent field absorption, and the operating band is 2.004 μm. The sensing effects of micro/nano fibers with different diameters are compared, and the experiment proves that a micro/nano fiber with a diameter of 1 μm can be measured. The light intensity change over 30 s was measured, and the breathing rate was 10–11 times/min. The sensor can achieve a rapid real-time response to CO2 gas detection and is small in size, low-cost, and easy to replace. It has a great application potential in clinical scenarios such as in gastrointestinal endoscopes that require real-time monitoring of human respiration.