DETERMINATION OF OPTIMAL WINDOW WIDTH AND LEVEL FOR MEASUREMENT OF THE CANINE PITUITARY GLAND HEIGHT ON COMPUTED TOMOGRAPHIC IMAGES USING A PHANTOM
Authors:
- 28 February 2007
- journal article
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 48 (2) , 113-117
Abstract
The purpose of this study was to determine the optimal window level and width for accurate measurement of pituitary gland height in a phantom. A phantom, mimicking the appearance of the pituitary gland, was made by using the base of a canine skull immersed in buttermilk. Seven different‐sized cylindrical pieces of cheese were made and the real diameter of each sample was measured by using a caliper. The cheese was then placed in the pituitary fossa, and 2‐mm thick contiguous computed tomography (CT) slices were acquired. The height of the cheese was measured using electronic calipers with different window width and level (WW–WL) settings. The mean difference between CT and manual caliper measurements and concordance correlation coefficients were calculated for all settings. CT measurements underestimated manual caliper measurements with all settings, but the smallest difference (0.5 mm) was obtained with a 250–80 window. Concordance coefficients ranged from 0.699 to 0.820, with the maximum concordance coefficient obtained with a 250–80 window. A second series of measurements using a different window setting for the brain–pituitary gland edge (WW–WL: 250–80) and for the bone–pituitary gland edge (WW–WL: 250–240) resulted in a reduction in the mean difference (0.1 mm) and an increase in the concordance coefficient (0.836). It was concluded that underestimation of the height of the pituitary gland on CT images is most likely due to erroneous placement of the edge of the basisphenoid bone using a low level and a narrow window.Keywords
This publication has 8 references indexed in Scilit:
- Intraobserver and interobserver agreement, reproducibility, and accuracy of computed tomographic measurements of pituitary gland dimensions in healthy dogsAmerican Journal of Veterinary Research, 2006
- Assessment of the accuracy of computed tomography for measurement of normal equine pituitary glandsAmerican Journal of Veterinary Research, 2003
- Imaging of the pituitary gland in dogs with pituitary-dependent hyperadrenocorticismMolecular and Cellular Endocrinology, 2002
- CT Angiographic Measurement of the Carotid Artery: Optimizing Visualization by Manipulating Window and Level Settings and Contrast Material AttenuationRadiology, 2000
- Results of Transsphenoidal Hypophysectomy in 52 Dogs With Pituitary‐Dependent HyperadrenocorticismVeterinary Surgery, 1998
- Correlation between impairment of glucocorticoid feedback and the size of the pituitary gland in dogs with pituitary-dependent hyperadrenocorticismJournal of Endocrinology, 1997
- APPARENT WALL THICKENING IN FLUID FILLED VERSUS AIR FILLED TYMPANIC BULLA IN COMPUTED TOMOGRAPHYVeterinary Radiology & Ultrasound, 1996
- Factors Affecting the Measurement of Size and CT Number in Computed TomographyInvestigative Radiology, 1981