Increased polyethylene wear after cementless ABG I total hip arthroplasty
- 21 June 2006
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 126 (8) , 509-516
Abstract
Introduction The cementless, hydroxyapatite-coated Anatomique Benoist Giraud-I (ABG-I) hip endoprosthesis represented a modern implant in the 1990s. The aim of the current retrospective study was to evaluate the clinical and radiological results of this prosthesis. In addition, an analysis of the complications and retrieved implants was conducted. Materials/methods The medium-term results (follow-up 5.23 years) of 193 hip joints are presented. Of 158 total cohorts, 81.9% was able to undergo follow-up performed with standardized clinical and radiological investigations. Physical characteristics of the patients and the underlying disease prompting the need for total hip arthroplasty, as well as a clinical score (Merle d’Aubigné) were recorded. At the time of follow-up, a radiologic examination of all patients with a standardized evaluation was performed. In addition, the migration of the acetabular cup and femoral head as well as polyethylene wear could be determined digitally in 118 cases (61.1%) using one-picture Roentgen analysis. Results Clinical results, as measured with a Merle d’Aubigné Score increase from 8.4 to 16.2, were very good. Radiographs demonstrated successful osseous integration of the anatomically molded shaft. Within the period of the investigation, no revision procedures of the femoral shaft were necessary. However, the rate of polyethylene abrasion of 0.23 mm/year was markedly high. 13.9% of hips (n = 27) required acetabular cup revision due to wear. This calculates to a prosthesis 7-year survival probability of 63%. Intraoperative findings during the revision cases showed extensive periacetabular osteolysis with foreign body granulation tissue. Analysis of data from the total patient cohort versus data from cases requiring revision showed a significantly increased frequency of high polyethylene wear in young active patients as well as in cases where an unfavorable acetabular cup to femoral head relation existed in correspondence with polyethylene thickness. There is evidence, however, that suggests that multifactorial causes for the increased wear are significant in regards to the principal material and technical features of the prosthesis. Conclusion On the basis of these results, it is strongly recommended that all patients treated with an ABG-I hip endoprosthesis should receive close clinical and most importantly close radiologic follow-up.Keywords
This publication has 16 references indexed in Scilit:
- Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- The ABG hydroxyapatite-coated hip prosthesisThe Journal of Arthroplasty, 2003
- Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine studyArchives of orthopaedic and trauma surgery, 2003
- Medium-term results of the ABG total hip arthroplasty in young patientsThe Journal of Arthroplasty, 2002
- New aspects in the histological examination of polyethylene wear particles in failed total joint replacementsActa Histochemica, 2002
- Hydroxyapatite coated hip prosthesis followed up for 5 yearsInternational Orthopaedics, 2001
- Wear Is a Function of Use, Not TimeClinical Orthopaedics and Related Research, 2000
- The hydroxyapatite-ABG hip systemThe Journal of Arthroplasty, 2000
- Rheumatoid arthritis and hydroxyapatite-coated hip prosthesesThe Journal of Arthroplasty, 1998
- EBRA: A method to measure migration of acetabular componentsJournal of Biomechanics, 1995