Karl-Stefan Delank
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karl-Stefan Delank has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Peer Eysel
Department of Orthopedics and Trauma Surgery, Faculty of Medicine, University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
3 shared publications Marc Röllinghoff
2 shared publicationsPeer Eysel
2 shared publications- Alexander Zeh
Department of Orthopaedics and Traumatology, Faculty of Medicine, Martin-Luther-University of Halle-Wittenberg, Magdeburger Str. 22, 06097 Halle/Saale, Germany
1 shared publication Anke Eckardt
Department of Orthopaedic Surgery, University of Mainz, Mainz, Germany
1 shared publicationClemens Wendtner
1 shared publication
Latest Publications
- 1 June 2012
- Vol. 78 (3) , 369-75
Quality of life and radiological outcome after cervical cage fusion and cervical disc arthroplasty.
In this retrospective comparative study, 42 patients with single-level cervical radiculopathy were operated upon, either with Shell cage fusion (23 patients) or with Prestige cervical disc arthroplasty (19 patients). The mean follow-up (FU) was 17.5 months (range: 5.6-42.1 months). Both treatments significantly improved all clinical parameters (VAS, ODI, SF36) (p < 0.001), without statistically relevant differences between the two groups. From a radiological viewpoint there was an obvious but statistically non-significant increase in the segmental height for both treatment groups. Segmental angle also increased in both groups, and the increase was significant (p < 0.05). As expected, range of motion (ROM) decreased significantly (p < 0.05) in the fusion group, while it was preserved in the arthroplasty group. Significantly more (p < 0.05) adjacent level degeneration class 1 to 4 was evident in the fusion group (8/23 or 34.8%) than in the arthroplasty group (3/19 or 15.8%). Two fusion patients (2/23 or 8.7%) developed painful clinical adjacent level disease requiring arthroplasty. The major conclusion was that significant adjacent level degenerative changes occurred in the cage group. Retained motion at the operative site seems to decrease the incidence of adjacent level degeneration. Implant subsidence was recorded at FU in 8 out of 42 patients (19%). It occurred significantly (p < 0.05) more often in the fusion group (6/23 or 26.1%) than in the arthroplasty group (2/19 or 10.5%), but it did not cause clinical symptoms. As in other studies, there is no explanation as to why better radiological results did not translate into better clinical outcomes within the time limits of the study.
- 1 June 2012
- Vol. 78 (3) , 369-75
Quality of life and radiological outcome after cervical cage fusion and cervical disc arthroplasty.
In this retrospective comparative study, 42 patients with single-level cervical radiculopathy were operated upon, either with Shell cage fusion (23 patients) or with Prestige cervical disc arthroplasty (19 patients). The mean follow-up (FU) was 17.5 months (range: 5.6-42.1 months). Both treatments significantly improved all clinical parameters (VAS, ODI, SF36) (p < 0.001), without statistically relevant differences between the two groups. From a radiological viewpoint there was an obvious but statistically non-significant increase in the segmental height for both treatment groups. Segmental angle also increased in both groups, and the increase was significant (p < 0.05). As expected, range of motion (ROM) decreased significantly (p < 0.05) in the fusion group, while it was preserved in the arthroplasty group. Significantly more (p < 0.05) adjacent level degeneration class 1 to 4 was evident in the fusion group (8/23 or 34.8%) than in the arthroplasty group (3/19 or 15.8%). Two fusion patients (2/23 or 8.7%) developed painful clinical adjacent level disease requiring arthroplasty. The major conclusion was that significant adjacent level degenerative changes occurred in the cage group. Retained motion at the operative site seems to decrease the incidence of adjacent level degeneration. Implant subsidence was recorded at FU in 8 out of 42 patients (19%). It occurred significantly (p < 0.05) more often in the fusion group (6/23 or 26.1%) than in the arthroplasty group (2/19 or 10.5%), but it did not cause clinical symptoms. As in other studies, there is no explanation as to why better radiological results did not translate into better clinical outcomes within the time limits of the study.
- 4 February 2011
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 108 (5) , 71-U27
The Treatment of Spinal Metastases
In recent years, the odds of surviving most kinds of cancer have improved. Bone metastases often arise in patients whose quality of life is not otherwise markedly impaired by their neoplastic disease. The types of primary tumor that most frequently...
- 4 February 2011
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 108 (5) , 71-U27
The Treatment of Spinal Metastases
In recent years, the odds of surviving most kinds of cancer have improved. Bone metastases often arise in patients whose quality of life is not otherwise markedly impaired by their neoplastic disease. The types of primary tumor that most frequently...
- 1 April 2010
- Vol. 76 (2) , 269-73
Pulmonary cement embolism after augmentation of pedicle screws with bone cement.
The authors present the very rare complication of widespread pulmonary artery cement embolism after pedicle screw augmentation with bone cement for multilevel spine fusion. A 69-year-old woman with severe osteoporosis underwent a posterior T12S1fusion because of lumbar scoliosis. After two months the superior pedicle screws loosened, and a revision spondylodesis T8L1 was performed with bone cement augmentation of the pedicle screws. Although cement leakage was seen paravertebrally, the patient was asymptomatic and reported distinct pain relief, so that no further investigations were initiated. Three months later, instability was identified in the adjacent superior segment. A CT-scan of the chest now revealed multiple pulmonary cement embolisms. Corpectomy T7 and extension spondylodesis T6T9 with an anterior single rod were performed. The pulmonary embolisms remained clinically silent and lung function was normal 18 months after surgery. The risk for cement embolism after pedicle screw augmentation has been established at 1/119 or 0.8%. After vertebroplasty and kyphoplasty it ranges from 3 to 23%. The existing literature offers no clear strategy for prevention or treatment of pulmonary cement embolism. The authors feel, as far as prevention is concerned, that creating a cavity by means of balloon distention before pedicle screw augmentation allows to inject the cement under lower pressure, so that the incidence of cement embolism might be reduced. Treatment options include, besides surgical removal in symptomatic embolism, heparin or warfarin treatment for 3 to 6 months.
- 1 April 2010
- Vol. 76 (2) , 269-73
Pulmonary cement embolism after augmentation of pedicle screws with bone cement.
The authors present the very rare complication of widespread pulmonary artery cement embolism after pedicle screw augmentation with bone cement for multilevel spine fusion. A 69-year-old woman with severe osteoporosis underwent a posterior T12S1fusion because of lumbar scoliosis. After two months the superior pedicle screws loosened, and a revision spondylodesis T8L1 was performed with bone cement augmentation of the pedicle screws. Although cement leakage was seen paravertebrally, the patient was asymptomatic and reported distinct pain relief, so that no further investigations were initiated. Three months later, instability was identified in the adjacent superior segment. A CT-scan of the chest now revealed multiple pulmonary cement embolisms. Corpectomy T7 and extension spondylodesis T6T9 with an anterior single rod were performed. The pulmonary embolisms remained clinically silent and lung function was normal 18 months after surgery. The risk for cement embolism after pedicle screw augmentation has been established at 1/119 or 0.8%. After vertebroplasty and kyphoplasty it ranges from 3 to 23%. The existing literature offers no clear strategy for prevention or treatment of pulmonary cement embolism. The authors feel, as far as prevention is concerned, that creating a cavity by means of balloon distention before pedicle screw augmentation allows to inject the cement under lower pressure, so that the incidence of cement embolism might be reduced. Treatment options include, besides surgical removal in symptomatic embolism, heparin or warfarin treatment for 3 to 6 months.
- 17 March 2010
- Published by Springer Nature in Der Orthopäde
- Vol. 39 (4) , 425-431
Degeneration and Osteoporosis of the Spine
Eine reduzierte Knochenqualität infolge einer Osteoporose stellt eine wesentliche Problematik bei der instrumentierten Wirbelsäulenchirurgie dar. Die zunehmende Ausweitung der Operationsindikationen auf ältere und alte Patienten führt im klinischen Alltag zu einer großen Relevanz dieser Problematik. Eine insuffiziente Implantatverankerung sowie die Anschlussfraktur sind die häufigsten beobachteten Folgen. Bei einer manifesten Osteoporose stehen verschiedene moderne Verankerungsmöglichkeiten zur Verfügung. Zementierbare Schrauben, die Kombination von Pedikelschrauben und Hakenverankerungen (Hybridinstrumentation), ein verändertes Schraubendesign und spezielle chirurgische Techniken können die Stabilität der Instrumentation mehr oder weniger erhöhen. Ob additiv applizierte Bisphosphonate die Verankerung tatsächlich verbessern, ist bislang noch nicht bewiesen. Die Zementaugmentation eines frakturierten Wirbels mittels Kypho- oder Vertebroplastie führt gegenüber einer konservativen Behandlung nachweislich zu einer signifikant besseren Schmerzreduktion, zumindest im kurzfristigen postoperativen Verlauf. Ein Verfahrensunterschied ist diesbezüglich bislang nicht nachgewiesen. Die Rate der sog. Anschlussfrakturen ist im Vergleich zu konservativ behandelten Patienten nach erfolgter Zementaugmentation nicht erhöht. Reduced bone quality due to osteoporosis poses a fundamental problem in spine surgery instrumentation. The consequences observed most often are insufficient implant anchoring and adjacent fractures. In cases of manifest osteoporosis, several modern anchoring possibilities are at our disposal that, to differing degrees, increase the stability of the instrumentation. Cement augmentation of a fractured vertebra by means of kyphoplasty or vertebroplasty verifiably leads to significantly better pain reduction than conservative treatment does, at least in the short-term postoperative course. A difference between these two techniques has not yet been substantiated. The rate of adjacent fractures occurring after cement augmentation is not higher than in conservatively treated patients.
- 17 March 2010
- Published by Springer Nature in Der Orthopäde
- Vol. 39 (4) , 425-431
Degeneration and Osteoporosis of the Spine
Eine reduzierte Knochenqualität infolge einer Osteoporose stellt eine wesentliche Problematik bei der instrumentierten Wirbelsäulenchirurgie dar. Die zunehmende Ausweitung der Operationsindikationen auf ältere und alte Patienten führt im klinischen Alltag zu einer großen Relevanz dieser Problematik. Eine insuffiziente Implantatverankerung sowie die Anschlussfraktur sind die häufigsten beobachteten Folgen. Bei einer manifesten Osteoporose stehen verschiedene moderne Verankerungsmöglichkeiten zur Verfügung. Zementierbare Schrauben, die Kombination von Pedikelschrauben und Hakenverankerungen (Hybridinstrumentation), ein verändertes Schraubendesign und spezielle chirurgische Techniken können die Stabilität der Instrumentation mehr oder weniger erhöhen. Ob additiv applizierte Bisphosphonate die Verankerung tatsächlich verbessern, ist bislang noch nicht bewiesen. Die Zementaugmentation eines frakturierten Wirbels mittels Kypho- oder Vertebroplastie führt gegenüber einer konservativen Behandlung nachweislich zu einer signifikant besseren Schmerzreduktion, zumindest im kurzfristigen postoperativen Verlauf. Ein Verfahrensunterschied ist diesbezüglich bislang nicht nachgewiesen. Die Rate der sog. Anschlussfrakturen ist im Vergleich zu konservativ behandelten Patienten nach erfolgter Zementaugmentation nicht erhöht. Reduced bone quality due to osteoporosis poses a fundamental problem in spine surgery instrumentation. The consequences observed most often are insufficient implant anchoring and adjacent fractures. In cases of manifest osteoporosis, several modern anchoring possibilities are at our disposal that, to differing degrees, increase the stability of the instrumentation. Cement augmentation of a fractured vertebra by means of kyphoplasty or vertebroplasty verifiably leads to significantly better pain reduction than conservative treatment does, at least in the short-term postoperative course. A difference between these two techniques has not yet been substantiated. The rate of adjacent fractures occurring after cement augmentation is not higher than in conservatively treated patients.
- 1 January 2010
- Published by Springer Nature
- p. 61-64
Wundheilungsstörung bei diabetischer Arthropathie: Behandlungsstrategien
- 1 January 2010
- Published by Springer Nature
- p. 61-64
Wundheilungsstörung bei diabetischer Arthropathie: Behandlungsstrategien
- 20 November 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (2) , 285-292
How does spinal canal decompression and dorsal stabilization affect segmental mobility? A biomechanical study
When decompression of the lumbar spinal canal is performed, segmental stability might be affected. Exactly which anatomical structures can thereby be resected without interfering with stability, and when, respectively how, additional stabilization is essential, has not been adequately investigated so far. The present investigation describes kinetic changes in a surgically treated motion segment as well as in its adjacent segments.
- 20 November 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (2) , 285-292
How does spinal canal decompression and dorsal stabilization affect segmental mobility? A biomechanical study
When decompression of the lumbar spinal canal is performed, segmental stability might be affected. Exactly which anatomical structures can thereby be resected without interfering with stability, and when, respectively how, additional stabilization is essential, has not been adequately investigated so far. The present investigation describes kinetic changes in a surgically treated motion segment as well as in its adjacent segments.
- 22 September 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (9) , 1083-1091
Spondylodiscitis in the elderly patient: clinical mid-term results and quality of life
Focusing on spondylodiscitis in elderly patients current literature does not contain much information. We performed a retrospective case series (n = 32) comparing conservative (group 1; n = 16) versus operative (group 2; n = 16) treated spondylodiscitis patients aged ≥65 years (mean age 74.9 years) from January 2002 to April 2004. The review of the medical records provided information about the pre-hospital time, the inpatient course and the time after discharge. At follow-up (FU) (mean 3.6 years) disease specific and general quality of life (QOL) questionnaires (COMI back patient self-assessment, ODI and SF-36) were administered. Altogether, 71.9% of the patients could be contacted; 12.5% had died since hospitalisation and 15.6% could not be contacted anymore. At FU based on the visual analogue scale, patients indicated an average of 3.2 for back pain and 2.5 for leg pain. ODI scoring yielded minimal disability for 38.9%, a moderate disability for 22.2%, a severe disability for 22.2% and for 11.1% a crippled situation; 5.6% were bed-ridden or exaggerated their symptoms. The SF-36 PCS amounted to an average of 38.2, the MCS 50.6. Owing to additional surgery-associated risks, operative treatment of spondylodiscitis feature a complication rate twice as high in the respective group, but general complications do not differ. At FU, no statistically remarkable difference concerning QOL and remaining pain became evident between the groups, the operated patients being more satisfied with regard to the treatment of spondylodiscitis. Ultimately, if surgery is indicated the operative risks should be borne in mind, but advanced age should not be the crucial factor in decision-making.
- 22 September 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (9) , 1083-1091
Spondylodiscitis in the elderly patient: clinical mid-term results and quality of life
Focusing on spondylodiscitis in elderly patients current literature does not contain much information. We performed a retrospective case series (n = 32) comparing conservative (group 1; n = 16) versus operative (group 2; n = 16) treated spondylodiscitis patients aged ≥65 years (mean age 74.9 years) from January 2002 to April 2004. The review of the medical records provided information about the pre-hospital time, the inpatient course and the time after discharge. At follow-up (FU) (mean 3.6 years) disease specific and general quality of life (QOL) questionnaires (COMI back patient self-assessment, ODI and SF-36) were administered. Altogether, 71.9% of the patients could be contacted; 12.5% had died since hospitalisation and 15.6% could not be contacted anymore. At FU based on the visual analogue scale, patients indicated an average of 3.2 for back pain and 2.5 for leg pain. ODI scoring yielded minimal disability for 38.9%, a moderate disability for 22.2%, a severe disability for 22.2% and for 11.1% a crippled situation; 5.6% were bed-ridden or exaggerated their symptoms. The SF-36 PCS amounted to an average of 38.2, the MCS 50.6. Owing to additional surgery-associated risks, operative treatment of spondylodiscitis feature a complication rate twice as high in the respective group, but general complications do not differ. At FU, no statistically remarkable difference concerning QOL and remaining pain became evident between the groups, the operated patients being more satisfied with regard to the treatment of spondylodiscitis. Ultimately, if surgery is indicated the operative risks should be borne in mind, but advanced age should not be the crucial factor in decision-making.
- 1 January 2008
- Published by Georg Thieme Verlag KG in Kinder- und Jugendmedizin
- Vol. 08 (07) , 415-427
Fibröse Knochenerkrankungen im Kindes- und Jugendalter – Diagnostik und therapeutische Strategien
Zusammenfassung: Das Skelettsystem des Menschen geht aus dem mesenchymalen Gewebe hervor und besteht hauptsächlich aus Knochen-und Knorpelgewebe. Zwischen den Knochenbälkchen und den Haver’schen Kanälchen findet sich Bindegewebe, aus dem tumoröse Veränderungen entstehen können. Die fibrösen Knochenerkrankungen sind gekennzeichnet durch ein fibröses Grundgerüst, das Fibroblasten enthält. Eine Vielzahl von fibrösen Knochenveränderungen wurde beschrieben. Die fibröse Dysplasie und das nicht ossifizierende Knochenfibrom als benigne Knochenläsionen stellen eine häufige Fehlentwicklung dar, die Kinder und Jugendliche befällt. Im Laufe des Wachstums nehmen die Herde an Größe und Anzahl zu. Es können sich Schmerzen, Frakturen und Deformitäten entwickeln, die eine lokale oder systemische Therapie erforderlich machen. Maligne fibröse Knochenerkrankungen sind ein seltenes Krankheitsbild und werden meist im jungen Erwachsenenalter diagnostiziert. Kinder und Jugendliche sind nur selten betroffen. Die Erkrankungen bedürfen eines interdisziplinären Behandlungsansatzes, da die Diagnostik und die Therapie eine ärztliche Herausforderung bedeuten.
- 1 January 2008
- Published by Georg Thieme Verlag KG in Kinder- und Jugendmedizin
- Vol. 08 (07) , 415-427
Fibröse Knochenerkrankungen im Kindes- und Jugendalter – Diagnostik und therapeutische Strategien
Zusammenfassung: Das Skelettsystem des Menschen geht aus dem mesenchymalen Gewebe hervor und besteht hauptsächlich aus Knochen-und Knorpelgewebe. Zwischen den Knochenbälkchen und den Haver’schen Kanälchen findet sich Bindegewebe, aus dem tumoröse Veränderungen entstehen können. Die fibrösen Knochenerkrankungen sind gekennzeichnet durch ein fibröses Grundgerüst, das Fibroblasten enthält. Eine Vielzahl von fibrösen Knochenveränderungen wurde beschrieben. Die fibröse Dysplasie und das nicht ossifizierende Knochenfibrom als benigne Knochenläsionen stellen eine häufige Fehlentwicklung dar, die Kinder und Jugendliche befällt. Im Laufe des Wachstums nehmen die Herde an Größe und Anzahl zu. Es können sich Schmerzen, Frakturen und Deformitäten entwickeln, die eine lokale oder systemische Therapie erforderlich machen. Maligne fibröse Knochenerkrankungen sind ein seltenes Krankheitsbild und werden meist im jungen Erwachsenenalter diagnostiziert. Kinder und Jugendliche sind nur selten betroffen. Die Erkrankungen bedürfen eines interdisziplinären Behandlungsansatzes, da die Diagnostik und die Therapie eine ärztliche Herausforderung bedeuten.
- 21 June 2006
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 126 (8) , 509-516
Increased polyethylene wear after cementless ABG I total hip arthroplasty
Introduction The cementless, hydroxyapatite-coated Anatomique Benoist Giraud-I (ABG-I) hip endoprosthesis represented a modern implant in the 1990s. The aim of the current retrospective study was to evaluate the clinical and radiological results of this prosthesis. In addition, an analysis of the complications and retrieved implants was conducted. Materials/methods The medium-term results (follow-up 5.23 years) of 193 hip joints are presented. Of 158 total cohorts, 81.9% was able to undergo follow-up performed with standardized clinical and radiological investigations. Physical characteristics of the patients and the underlying disease prompting the need for total hip arthroplasty, as well as a clinical score (Merle d’Aubigné) were recorded. At the time of follow-up, a radiologic examination of all patients with a standardized evaluation was performed. In addition, the migration of the acetabular cup and femoral head as well as polyethylene wear could be determined digitally in 118 cases (61.1%) using one-picture Roentgen analysis. Results Clinical results, as measured with a Merle d’Aubigné Score increase from 8.4 to 16.2, were very good. Radiographs demonstrated successful osseous integration of the anatomically molded shaft. Within the period of the investigation, no revision procedures of the femoral shaft were necessary. However, the rate of polyethylene abrasion of 0.23 mm/year was markedly high. 13.9% of hips (n = 27) required acetabular cup revision due to wear. This calculates to a prosthesis 7-year survival probability of 63%. Intraoperative findings during the revision cases showed extensive periacetabular osteolysis with foreign body granulation tissue. Analysis of data from the total patient cohort versus data from cases requiring revision showed a significantly increased frequency of high polyethylene wear in young active patients as well as in cases where an unfavorable acetabular cup to femoral head relation existed in correspondence with polyethylene thickness. There is evidence, however, that suggests that multifactorial causes for the increased wear are significant in regards to the principal material and technical features of the prosthesis. Conclusion On the basis of these results, it is strongly recommended that all patients treated with an ABG-I hip endoprosthesis should receive close clinical and most importantly close radiologic follow-up.
- 21 June 2006
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 126 (8) , 509-516
Increased polyethylene wear after cementless ABG I total hip arthroplasty
Introduction The cementless, hydroxyapatite-coated Anatomique Benoist Giraud-I (ABG-I) hip endoprosthesis represented a modern implant in the 1990s. The aim of the current retrospective study was to evaluate the clinical and radiological results of this prosthesis. In addition, an analysis of the complications and retrieved implants was conducted. Materials/methods The medium-term results (follow-up 5.23 years) of 193 hip joints are presented. Of 158 total cohorts, 81.9% was able to undergo follow-up performed with standardized clinical and radiological investigations. Physical characteristics of the patients and the underlying disease prompting the need for total hip arthroplasty, as well as a clinical score (Merle d’Aubigné) were recorded. At the time of follow-up, a radiologic examination of all patients with a standardized evaluation was performed. In addition, the migration of the acetabular cup and femoral head as well as polyethylene wear could be determined digitally in 118 cases (61.1%) using one-picture Roentgen analysis. Results Clinical results, as measured with a Merle d’Aubigné Score increase from 8.4 to 16.2, were very good. Radiographs demonstrated successful osseous integration of the anatomically molded shaft. Within the period of the investigation, no revision procedures of the femoral shaft were necessary. However, the rate of polyethylene abrasion of 0.23 mm/year was markedly high. 13.9% of hips (n = 27) required acetabular cup revision due to wear. This calculates to a prosthesis 7-year survival probability of 63%. Intraoperative findings during the revision cases showed extensive periacetabular osteolysis with foreign body granulation tissue. Analysis of data from the total patient cohort versus data from cases requiring revision showed a significantly increased frequency of high polyethylene wear in young active patients as well as in cases where an unfavorable acetabular cup to femoral head relation existed in correspondence with polyethylene thickness. There is evidence, however, that suggests that multifactorial causes for the increased wear are significant in regards to the principal material and technical features of the prosthesis. Conclusion On the basis of these results, it is strongly recommended that all patients treated with an ABG-I hip endoprosthesis should receive close clinical and most importantly close radiologic follow-up.
- Open Access
- 3 March 2006
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 7 (1) , 20
The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: Results from a prospective, blinded study
Background: The most frequent complications of joint arthroplasty are septic or aseptic loosening of endoprostheses. Preoperative differentiation is essential, since very different treatment methods result from the diagnoses. The aim of the current study was to evaluate the clinical value of 18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG PET) as a diagnostic modality for inflammation and loosening in hip and knee joint prostheses. Methods: 18F-FDG-PET examinations and multiphase bone scan were performed on hip and knee endoprostheses in 27 patients prior to revision surgical procedures planned for prosthetic loosening. Intact prostheses were found at the opposite site in some patients so that additional 9 joints could be examined with the field of view of 18F-FDG PET. Verification and valuation of the PET and scintigraphic image findings were conducted by comparing them with information combined from intraoperative findings, histopathology, and microbiological investigations. Results: Evidence of loosening was correctly determined in 76.4% of cases using 18F-FDG-PET, and in 75% of cases using bone scan. The detection of periprosthetic inflammation using 18F-FDG-PET had a sensitivity of 100% for septic cases and of 45.5% in cases of increased abrasion and aseptic foreign-body reactions. However, reliable differentiation between abrasion-induced and bacterial-caused inflammation was not possible using 18F-FDG-PET. Conclusion: 18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG-PET) allows reliable prediction of peri-prosthetic septical inflammatory tissue reactions. Because of the high sensitivity of this method, a negative PET result in the setting of a diagnostically unclear situation eliminates the need for revision surgery. In contrast, a positive PET result gives no clear differentiation regarding the cause of inflammation.
- 3 March 2006
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 7 (1) , 20
Open AccessThe implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: Results from a prospective, blinded study
Background: The most frequent complications of joint arthroplasty are septic or aseptic loosening of endoprostheses. Preoperative differentiation is essential, since very different treatment methods result from the diagnoses. The aim of the current study was to evaluate the clinical value of 18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG PET) as a diagnostic modality for inflammation and loosening in hip and knee joint prostheses. Methods: 18F-FDG-PET examinations and multiphase bone scan were performed on hip and knee endoprostheses in 27 patients prior to revision surgical procedures planned for prosthetic loosening. Intact prostheses were found at the opposite site in some patients so that additional 9 joints could be examined with the field of view of 18F-FDG PET. Verification and valuation of the PET and scintigraphic image findings were conducted by comparing them with information combined from intraoperative findings, histopathology, and microbiological investigations. Results: Evidence of loosening was correctly determined in 76.4% of cases using 18F-FDG-PET, and in 75% of cases using bone scan. The detection of periprosthetic inflammation using 18F-FDG-PET had a sensitivity of 100% for septic cases and of 45.5% in cases of increased abrasion and aseptic foreign-body reactions. However, reliable differentiation between abrasion-induced and bacterial-caused inflammation was not possible using 18F-FDG-PET. Conclusion: 18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG-PET) allows reliable prediction of peri-prosthetic septical inflammatory tissue reactions. Because of the high sensitivity of this method, a negative PET result in the setting of a diagnostically unclear situation eliminates the need for revision surgery. In contrast, a positive PET result gives no clear differentiation regarding the cause of inflammation.