The use of instantaneous phase for improving sparse arrays images
- 1 July 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 974-977
Abstract
Sparse arrays have pitch larger than halfwavelength (λ/2) and there is a reduced number of elements in comparison with a full-populated array. Consequently, there is a reduction in cost, data acquisition and processing. However, conventional beamforming techniques result in large side and grating lobes, and consequently in image artifacts. In this work the instantaneous phase of the signals is used in a beamforming technique instead of the instantaneous amplitudes to improve images obtained from sparse arrays configurations. A threshold based on a statistical analysis and the number of signals used for imaging is applied to each pixel, in order to determine if that pixel is related to a defect or not. Three sets of data are used to evaluate the technique, considering medical and non-destructive testing: a simulated point spread function, a medical phantom and an aluminum plate with 2λ-, 7λ- and λ-pitch, respectively. The conventional amplitude image is superposed by the image improved by the instantaneous phase, increasing the reflectors detectability and reducing artifacts for all cases, as well as dead zone for the tested plate.Keywords
This publication has 9 references indexed in Scilit:
- Damage characterization using guided- wave linear arrays and image compounding techniquesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2010
- Phase Coherence ImagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- Defect characterization using an ultrasonic array to measure the scattering coefficient matrixIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Synthetic aperture ultrasound imagingUltrasonics, 2006
- Post-processing of the full matrix of ultrasonic transmit–receive array data for non-destructive evaluationNDT & E International, 2005
- A method of reducing grating lobes associated with an ultrasound linear phased array intended for transrectal thermotherapyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Optimizing the radiation pattern of sparse periodic linear arraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996
- Nonlinear apodization for sidelobe control in SAR imageryIEEE Transactions on Aerospace and Electronic Systems, 1995
- Beam steering with pulsed two-dimensional transducer arraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1991