Comparison of neutron contamination in small photon fields of secondary collimator jaws and circular cones
Authors:
- 29 September 2023
- journal article
- research article
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, e107
Abstract
Introduction: Advanced treatment modalities involve applying small fields which might be shaped by collimators or circular cones. In these techniques, high-energy photons produce unwanted neutrons. Therefore, it is necessary to know neutron parameters in these techniques. Materials and methods: Different parts of Varian linac were simulated by MCNPX, and different neutron parameters were calculated. The results were then compared to photoneutron production in the same nominal fields created by circular cones. Results: Maximum neutron fluence for 1 × 1, 2 × 2, 3 × 3 cm2 field sizes was 165, 40.4, 19.78 (cm–2.Gy-1 × 106), respectively. The maximum values of neutron equivalent doses were 17.1, 4.65, 2.44 (mSv/Gy of photon dose) for 1 × 1, 2 × 2, 3 × 3 cm2 field size, respectively, and maximum neutron absorbed doses reached 903, 253, 131 (µGy/Gy photon dose) for 1 × 1, 2 × 2, 3 × 3 cm2 field sizes, respectively. Conclusion: Comparing the results with those in the presence of circular cones showed that circular cones reduce photoneutron production for the same nominal field sizes.Keywords
This publication has 16 references indexed in Scilit:
- Monte Carlo calculation of photo-neutron dose produced by circular cones at 18 MV photon beamsReports of Practical Oncology and Radiotherapy, 2018
- Measurement of neutron dose in the compensator IMRT treatmentApplied Radiation and Isotopes, 2017
- Cancer and Treatment ModalitiesCurrent Cancer Therapy Reviews, 2017
- A Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear acceleratorInternational Journal of Advanced Biological and Biomedical Research, 2016
- Neutron dose equivalent and neutron spectra in tissue for clinical linacs operating at 15, 18 and 20 MVRadiation Protection Dosimetry, 2011
- A review on photoneutrons characteristics in radiation therapy with high-energy photon beamsReports of Practical Oncology and Radiotherapy, 2010
- Neutron spectra and dose equivalents calculated in tissue for high‐energy radiation therapyMedical Physics, 2009
- Doses to patients from photoneutrons emitted in a medical linear acceleratorRadiation Protection Dosimetry, 2009
- Monte Carlo simulation of the photoneutron field in linac radiotherapy treatments with different collimation systemsPhysics in Medicine & Biology, 2004
- Monte Carlo variance reduction with deterministic importance functionsProgress in Nuclear Energy, 2003