Nooshin Banaee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nooshin Banaee has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hassan Ali Nedaie
Department of Medical Physics & Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
3 shared publications Hassan Ali Nedaie
Radiation Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
2 shared publicationsKiarash Goodarzi
Medical Radiation Research Center, Central Tehran Branch, Islamic Azad University, Tehran, Iran
2 shared publications- Ali Kazemian
Department of Radiation Oncology, Cancer Institute, Imam Khomeini Hospital Complex, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
1 shared publication Elham Hosseinzadeh
Department of Medical Physics, Faculty of Medicine, Jundishapur University of Medical Sciences, Ahvaz, Iran
1 shared publication- Ghazale Geraily
Tehran University of Medical Sciences
1 shared publication
Latest Publications
- 24 August 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (34) , 345301
Enhanced radiosensitization using TiO 2 and HfO 2 nanoparticles in Gamma Knife radiosurgery: insights from GEANT4 and GEANT4-DNA simulations
This study employs GEANT4 and GEANT4-DNA Monte Carlo simulations to evaluate the radiosensitization effects of titanium dioxide (TiO 2 ) and hafnium dioxide (HfO 2 ) nanoparticles (NPs) in Gamma Knife ICON radiosurgery. A multi scale simulation was performed to calculate dose enhancement factor (DEF) as well as DNA damage enhancement factor (DDEF) due to the presence of 20, 53, and 106 mg ml −1 TiO 2 and HfO 2 NPs with a size of 30, 65, or 100 nm. Increasing NP concentration and size resulted in higher DEF and DDEF, with HfO 2 outperforming TiO 2 due to its higher density and effective atomic number. Increasing NP concentration from 20 to 106 mg ml −1 raised the DEF by up to 10.5% for HfO 2 and 6.82% for TiO 2 , while increasing NP diameter from 30 to 100 nm resulted in DEF increases of up to 3.10% and 2.10%, respectively. DNA damage yields (single- and double-strand breaks) followed similar trends, corroborating the enhanced radiobiological impact. Cell survival curves (obtained by Two-Lesion Kinetic model) demonstrated increased radiosensitization with higher NP concentration and size, particularly for HfO 2 . These findings suggest that HfO 2 NPs represent a promising high- Z sensitizer for enhancing therapeutic efficacy in radiosurgery, warranting further comparative studies against established sensitizers such as gold.
- 24 August 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (34) , 345301
Enhanced radiosensitization using TiO 2 and HfO 2 nanoparticles in Gamma Knife radiosurgery: insights from GEANT4 and GEANT4-DNA simulations
This study employs GEANT4 and GEANT4-DNA Monte Carlo simulations to evaluate the radiosensitization effects of titanium dioxide (TiO 2 ) and hafnium dioxide (HfO 2 ) nanoparticles (NPs) in Gamma Knife ICON radiosurgery. A multi scale simulation was performed to calculate dose enhancement factor (DEF) as well as DNA damage enhancement factor (DDEF) due to the presence of 20, 53, and 106 mg ml −1 TiO 2 and HfO 2 NPs with a size of 30, 65, or 100 nm. Increasing NP concentration and size resulted in higher DEF and DDEF, with HfO 2 outperforming TiO 2 due to its higher density and effective atomic number. Increasing NP concentration from 20 to 106 mg ml −1 raised the DEF by up to 10.5% for HfO 2 and 6.82% for TiO 2 , while increasing NP diameter from 30 to 100 nm resulted in DEF increases of up to 3.10% and 2.10%, respectively. DNA damage yields (single- and double-strand breaks) followed similar trends, corroborating the enhanced radiobiological impact. Cell survival curves (obtained by Two-Lesion Kinetic model) demonstrated increased radiosensitization with higher NP concentration and size, particularly for HfO 2 . These findings suggest that HfO 2 NPs represent a promising high- Z sensitizer for enhancing therapeutic efficacy in radiosurgery, warranting further comparative studies against established sensitizers such as gold.
- 1 December 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (12) , 125304
Assessing magnetic field effects on gamma knife dose distribution in heterogeneous tissues: insights from Geant4 simulations
This study investigates the impacts of magnetic fields (0–7 Tesla) on Gamma Knife dose distribution using Monte Carlo simulations with GEANT4. Simulations were performed using both homogeneous water phantoms and heterogeneous phantoms containing bone, air, and soft tissue equivalent layers, employing 4, 8, and 16 mm collimators. Full width at half maximum (FWHM) and penumbra characteristics were calculated from dose profiles. The simulations incorporated realistic magnetic field gradients to approximate clinical MRI conditions. Results demonstrated the the magnetic field-induced shift of high-dose isodose lines, with displacements of 0.5–1.25 mm observed along the longitudinal (z-) axis, a magnitude of high relevance for radiosurgical precision. While magnetic fields ≤3 Tesla showed minor effects, the 7 Tesla field produced significant modifications, including a penumbra reduction of up to 5.8% and localized point-by-point dose changes exceeding 30% in two-dimensional distributions. In the heterogeneous phantom, the 7 Tesla field caused a deformation of the dose near interfaces, with a relative shift of the 90% isodose line by up to 65.8% and a 16% dose enhancement at bone-air boundaries due to the electron return effect. These results demonstrate that strong magnetic fields can induce significant distortions in dose distribution, highlighting the imperative for treatment planning systems to account for these effects, particularly near tissue interfaces in MRI-guided radiosurgery.
- 1 December 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (12) , 125304
Assessing magnetic field effects on gamma knife dose distribution in heterogeneous tissues: insights from Geant4 simulations
This study investigates the impacts of magnetic fields (0–7 Tesla) on Gamma Knife dose distribution using Monte Carlo simulations with GEANT4. Simulations were performed using both homogeneous water phantoms and heterogeneous phantoms containing bone, air, and soft tissue equivalent layers, employing 4, 8, and 16 mm collimators. Full width at half maximum (FWHM) and penumbra characteristics were calculated from dose profiles. The simulations incorporated realistic magnetic field gradients to approximate clinical MRI conditions. Results demonstrated the the magnetic field-induced shift of high-dose isodose lines, with displacements of 0.5–1.25 mm observed along the longitudinal (z-) axis, a magnitude of high relevance for radiosurgical precision. While magnetic fields ≤3 Tesla showed minor effects, the 7 Tesla field produced significant modifications, including a penumbra reduction of up to 5.8% and localized point-by-point dose changes exceeding 30% in two-dimensional distributions. In the heterogeneous phantom, the 7 Tesla field caused a deformation of the dose near interfaces, with a relative shift of the 90% isodose line by up to 65.8% and a 16% dose enhancement at bone-air boundaries due to the electron return effect. These results demonstrate that strong magnetic fields can induce significant distortions in dose distribution, highlighting the imperative for treatment planning systems to account for these effects, particularly near tissue interfaces in MRI-guided radiosurgery.
- Open Access
- 1 October 2025
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 50 (4) , 615-625
Dose Enhancement Due to Various Nanoparticles Irradiated by Megavoltage Photon Beams: A Review Study
Nowadays, the use of nanotechnology in cancer treatment offers exciting possibilities, including the enhanced delivery of doses inside the target, leading to a higher therapeutic ratio. The aim of this study is to review the dose enhancement factor (DEF) of various nanoparticles (NPs) in megavoltage radiotherapy. In vitro , Monte Carlo (MC) and experimental methods were employed in the reviewed studies, and the results indicated that higher DEF values were achieved through in vitro methods. According to the literature, smaller NPs tend to exhibit higher sensitization enhancement ratio (SER) in in vitro studies. In contrast, MC simulations report that NPs with higher concentrations, larger sizes, and higher atomic numbers led to greater DEF values. Smaller NPs penetrated tumors more effectively, whereas larger NPs had greater self-absorption of secondary electrons. It was also demonstrated that the increase in size may also result in higher toxicity and accumulation of NPs in tissues. A suitable balance between therapeutic efficacy, minimal toxicity, and uptake-related issues should be considered. Among the conducted studies, spherical and rod-shaped NPs have been more widely used. In addition, gold (Au) NPs in the size of 100 nm and concentration of 6 mM irradiating by 6 MeV photon beams have shown higher DEF values compared to other NPs in both MC and experimental methods (the maximum DEF reported was 4.71, representing a 53% increase for a 6 mM gel). Meanwhile, bismuth oxide (Bi₂O₃) NPs demonstrated the highest SER in in vitro studies, with a maximum SER of 7.64 for 90 nm particles at a concentration of 0.05 µM.
- 1 October 2025
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 50 (4) , 615-625
Open AccessDose Enhancement Due to Various Nanoparticles Irradiated by Megavoltage Photon Beams: A Review Study
Nowadays, the use of nanotechnology in cancer treatment offers exciting possibilities, including the enhanced delivery of doses inside the target, leading to a higher therapeutic ratio. The aim of this study is to review the dose enhancement factor (DEF) of various nanoparticles (NPs) in megavoltage radiotherapy. In vitro , Monte Carlo (MC) and experimental methods were employed in the reviewed studies, and the results indicated that higher DEF values were achieved through in vitro methods. According to the literature, smaller NPs tend to exhibit higher sensitization enhancement ratio (SER) in in vitro studies. In contrast, MC simulations report that NPs with higher concentrations, larger sizes, and higher atomic numbers led to greater DEF values. Smaller NPs penetrated tumors more effectively, whereas larger NPs had greater self-absorption of secondary electrons. It was also demonstrated that the increase in size may also result in higher toxicity and accumulation of NPs in tissues. A suitable balance between therapeutic efficacy, minimal toxicity, and uptake-related issues should be considered. Among the conducted studies, spherical and rod-shaped NPs have been more widely used. In addition, gold (Au) NPs in the size of 100 nm and concentration of 6 mM irradiating by 6 MeV photon beams have shown higher DEF values compared to other NPs in both MC and experimental methods (the maximum DEF reported was 4.71, representing a 53% increase for a 6 mM gel). Meanwhile, bismuth oxide (Bi₂O₃) NPs demonstrated the highest SER in in vitro studies, with a maximum SER of 7.64 for 90 nm particles at a concentration of 0.05 µM.
- 1 September 2025
- Published by InkVista Publishing House in Journal Of Modern Research Physics
- Vol. 10 (1) , 14-26
Investigation and Comparison of Dose Distribution Between the Convolution Algorithm and Monte Carlo Simulation in the Gamma Knife Device for Brain Tumor Treatment
سرطان یکی از چالشهای بزرگ بشری است که نیاز به روشهای درمانی دقیق و مؤثر دارد. در این راستا، تکنیکهای نوین مانند استریوتاکتیک رادیوسرجری و دستگاههای پیشرفته مانند گامانایف برای درمان تومورهای مغزی به کار میروند. الگوریتم کانوولوشن به دلیل توانایی در تشخیص ناهمگنی بافت و شبیهسازی مونتکارلو به عنوان دقیقترین روش محاسبه دز، مورد توجه قرار دارند. در این مطالعه، دستگاه گامانایف با استفاده از کد مونتکارلو شبیهسازی شد و توزیع دز بر روی یک فانتوم ناهمگن محاسبه گردید. سپس، این فانتوم تحت تصویربرداری سیتی قرار گرفت و در سیستم گامانایف تحلیل شد. نتایج نشان داد که در میانه پروفایل دز، اختلاف توزیع دز کم است، اما در حاشیهها افزایش مییابد. این مطالعه به بهبود دقت درمانی و کاهش عوارض جانبی کمک میکند.
- 1 September 2025
- Published by InkVista Publishing House in Journal Of Modern Research Physics
- Vol. 10 (1) , 14-26
Investigation and Comparison of Dose Distribution Between the Convolution Algorithm and Monte Carlo Simulation in the Gamma Knife Device for Brain Tumor Treatment
سرطان یکی از چالشهای بزرگ بشری است که نیاز به روشهای درمانی دقیق و مؤثر دارد. در این راستا، تکنیکهای نوین مانند استریوتاکتیک رادیوسرجری و دستگاههای پیشرفته مانند گامانایف برای درمان تومورهای مغزی به کار میروند. الگوریتم کانوولوشن به دلیل توانایی در تشخیص ناهمگنی بافت و شبیهسازی مونتکارلو به عنوان دقیقترین روش محاسبه دز، مورد توجه قرار دارند. در این مطالعه، دستگاه گامانایف با استفاده از کد مونتکارلو شبیهسازی شد و توزیع دز بر روی یک فانتوم ناهمگن محاسبه گردید. سپس، این فانتوم تحت تصویربرداری سیتی قرار گرفت و در سیستم گامانایف تحلیل شد. نتایج نشان داد که در میانه پروفایل دز، اختلاف توزیع دز کم است، اما در حاشیهها افزایش مییابد. این مطالعه به بهبود دقت درمانی و کاهش عوارض جانبی کمک میکند.
- Open Access
- 6 February 2024
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 23, e5
Evaluating the performance of automated external contouring tool on dose calculation of treatment planning system
Introduction: The main goal of radiation therapy is to eradicate all cancer cells and minimize the damage to healthy tissues around the tumour. Treatment planning systems are used to predict the outcome of the treatment in terms of dose distribution prior to the treatment. One of the most reliable dose calculation algorithms is Monte Carlo. The aim of this study is to evaluate the performance of automated external contouring tool on dose calculation using Monte Carlo algorithm. Materials and methods: The external contour of thorax phantom was created by automated tools of Monaco treatment planning system, and then, the IAEA-TECDOC-1583 quality assurance tests were created. Then, the treatment plans were delivered to the phantom, and the dose was measured by the Farmer ionization chamber at specific points. The external contour was corrected according to the source surface distances (SSD) which are mentioned in TECDOC-1583, and the dose was re-calculated. Finally, a comparison was made between the results. Results: Dosimetric tests of TECDOC-1583 showed the errors ranged from −2·8% to +2·5%. In case of editing external contour and omitting fluctuations, the errors were decreased. The comparisons indicated that the most significant variation occurred in test 4 and the least changes were related to the tests 1 and 3. Conclusions: The results of the study showed that the fluctuations of the external contour affect the calculated volume of the phantom and thus the dose. In order to obtain correct results, automated external contouring tools should be used with the correct instructions and re-checked before treatment planning.
- 6 February 2024
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 23, e5
Open AccessEvaluating the performance of automated external contouring tool on dose calculation of treatment planning system
Introduction: The main goal of radiation therapy is to eradicate all cancer cells and minimize the damage to healthy tissues around the tumour. Treatment planning systems are used to predict the outcome of the treatment in terms of dose distribution prior to the treatment. One of the most reliable dose calculation algorithms is Monte Carlo. The aim of this study is to evaluate the performance of automated external contouring tool on dose calculation using Monte Carlo algorithm. Materials and methods: The external contour of thorax phantom was created by automated tools of Monaco treatment planning system, and then, the IAEA-TECDOC-1583 quality assurance tests were created. Then, the treatment plans were delivered to the phantom, and the dose was measured by the Farmer ionization chamber at specific points. The external contour was corrected according to the source surface distances (SSD) which are mentioned in TECDOC-1583, and the dose was re-calculated. Finally, a comparison was made between the results. Results: Dosimetric tests of TECDOC-1583 showed the errors ranged from −2·8% to +2·5%. In case of editing external contour and omitting fluctuations, the errors were decreased. The comparisons indicated that the most significant variation occurred in test 4 and the least changes were related to the tests 1 and 3. Conclusions: The results of the study showed that the fluctuations of the external contour affect the calculated volume of the phantom and thus the dose. In order to obtain correct results, automated external contouring tools should be used with the correct instructions and re-checked before treatment planning.
- 29 September 2023
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, e107
Comparison of neutron contamination in small photon fields of secondary collimator jaws and circular cones
Introduction: Advanced treatment modalities involve applying small fields which might be shaped by collimators or circular cones. In these techniques, high-energy photons produce unwanted neutrons. Therefore, it is necessary to know neutron parameters in these techniques. Materials and methods: Different parts of Varian linac were simulated by MCNPX, and different neutron parameters were calculated. The results were then compared to photoneutron production in the same nominal fields created by circular cones. Results: Maximum neutron fluence for 1 × 1, 2 × 2, 3 × 3 cm2 field sizes was 165, 40.4, 19.78 (cm–2.Gy-1 × 106), respectively. The maximum values of neutron equivalent doses were 17.1, 4.65, 2.44 (mSv/Gy of photon dose) for 1 × 1, 2 × 2, 3 × 3 cm2 field size, respectively, and maximum neutron absorbed doses reached 903, 253, 131 (µGy/Gy photon dose) for 1 × 1, 2 × 2, 3 × 3 cm2 field sizes, respectively. Conclusion: Comparing the results with those in the presence of circular cones showed that circular cones reduce photoneutron production for the same nominal field sizes.
- 29 September 2023
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, e107
Comparison of neutron contamination in small photon fields of secondary collimator jaws and circular cones
Introduction: Advanced treatment modalities involve applying small fields which might be shaped by collimators or circular cones. In these techniques, high-energy photons produce unwanted neutrons. Therefore, it is necessary to know neutron parameters in these techniques. Materials and methods: Different parts of Varian linac were simulated by MCNPX, and different neutron parameters were calculated. The results were then compared to photoneutron production in the same nominal fields created by circular cones. Results: Maximum neutron fluence for 1 × 1, 2 × 2, 3 × 3 cm2 field sizes was 165, 40.4, 19.78 (cm–2.Gy-1 × 106), respectively. The maximum values of neutron equivalent doses were 17.1, 4.65, 2.44 (mSv/Gy of photon dose) for 1 × 1, 2 × 2, 3 × 3 cm2 field size, respectively, and maximum neutron absorbed doses reached 903, 253, 131 (µGy/Gy photon dose) for 1 × 1, 2 × 2, 3 × 3 cm2 field sizes, respectively. Conclusion: Comparing the results with those in the presence of circular cones showed that circular cones reduce photoneutron production for the same nominal field sizes.
- Open Access
- 1 August 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 5 (1) , 20220062
The geometric and dosimetric accuracy of kilovoltage cone beam computed tomography images for adaptive treatment: a systematic review
Objectives: To provide an overview and meta-analysis of different techniques adopted to accomplish kVCBCT for dose calculation and automated segmentation. Methods: A systematic review and meta-analysis were performed on eligible studies demonstrating kVCBCT-based dose calculation and automated contouring of different tumor features. Meta-analysis of the performance was accomplished on the reported γ analysis and dice similarity coefficient (DSC) score of both collected results as three subgroups (head and neck, chest, and abdomen). Results: After the literature scrutinization (n = 1008), 52 papers were recognized for the systematic review. Nine studies of dosimtric studies and eleven studies of geometric analysis were suitable for inclusion in meta-analysis. Using kVCBCT for treatment replanning depends on a method used. Deformable Image Registration (DIR) methods yielded small dosimetric error (≤2%), γ pass rate (≥90%) and DSC (≥0.8). Hounsfield Unit (HU) override and calibration curve-based methods also achieved satisfactory yielded small dosimetric error (≤2%) and γ pass rate ((≥90%), but they are prone to error due to their sensitivity to a vendor-specific variation in kVCBCT image quality. Conclusions: Large cohorts of patients ought to be undertaken to validate methods achieving low levels of dosimetric and geometric errors. Quality guidelines should be established when reporting on kVCBCT, which include agreed metrics for reporting on the quality of corrected kVCBCT and defines protocols of new site-specific standardized imaging used when obtaining kVCBCT images for adaptive radiotherapy. Advances in knowledge: This review gives useful knowledge about methods making kVCBCT feasible for kVCBCT-based adaptive radiotherapy, simplifying patient pathway and reducing concomitant imaging dose to the patient.
- 1 August 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 5 (1) , 20220062
Open AccessThe geometric and dosimetric accuracy of kilovoltage cone beam computed tomography images for adaptive treatment: a systematic review
Objectives: To provide an overview and meta-analysis of different techniques adopted to accomplish kVCBCT for dose calculation and automated segmentation. Methods: A systematic review and meta-analysis were performed on eligible studies demonstrating kVCBCT-based dose calculation and automated contouring of different tumor features. Meta-analysis of the performance was accomplished on the reported γ analysis and dice similarity coefficient (DSC) score of both collected results as three subgroups (head and neck, chest, and abdomen). Results: After the literature scrutinization (n = 1008), 52 papers were recognized for the systematic review. Nine studies of dosimtric studies and eleven studies of geometric analysis were suitable for inclusion in meta-analysis. Using kVCBCT for treatment replanning depends on a method used. Deformable Image Registration (DIR) methods yielded small dosimetric error (≤2%), γ pass rate (≥90%) and DSC (≥0.8). Hounsfield Unit (HU) override and calibration curve-based methods also achieved satisfactory yielded small dosimetric error (≤2%) and γ pass rate ((≥90%), but they are prone to error due to their sensitivity to a vendor-specific variation in kVCBCT image quality. Conclusions: Large cohorts of patients ought to be undertaken to validate methods achieving low levels of dosimetric and geometric errors. Quality guidelines should be established when reporting on kVCBCT, which include agreed metrics for reporting on the quality of corrected kVCBCT and defines protocols of new site-specific standardized imaging used when obtaining kVCBCT images for adaptive radiotherapy. Advances in knowledge: This review gives useful knowledge about methods making kVCBCT feasible for kVCBCT-based adaptive radiotherapy, simplifying patient pathway and reducing concomitant imaging dose to the patient.
- Open Access
- 31 August 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (6) , 947-954
Neutron contamination in radiotherapy processes: a review study
Using high-energy photon beams is one of the most practical methods in radiotherapy treatment of cases in deep site located tumors. In such treatments, neutron contamination induced through photoneutron interaction of high energy photons (>8 MeV) with high Z materials of LINAC structures is the most crucial issue which should be considered. Generated neutrons will affect shielding calculations and cause extra doses to the patient and the probability of increase induced secondary cancer risks. In this study, different parameters of neutron production in radiotherapy processes will be reviewed.
- 31 August 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (6) , 947-954
Open AccessNeutron contamination in radiotherapy processes: a review study
Using high-energy photon beams is one of the most practical methods in radiotherapy treatment of cases in deep site located tumors. In such treatments, neutron contamination induced through photoneutron interaction of high energy photons (>8 MeV) with high Z materials of LINAC structures is the most crucial issue which should be considered. Generated neutrons will affect shielding calculations and cause extra doses to the patient and the probability of increase induced secondary cancer risks. In this study, different parameters of neutron production in radiotherapy processes will be reviewed.
- 27 April 2020
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 25 (4) , 515-520
Enhanced dose measurement of zinc oxide nanoparticles by radiochromic polymer dosimeter and Monte Carlo simulation
Aim: The aim of this study is to evaluate the effects of Zinc Oxide nanoparticles on dose enhancement factor using PRESAGE dosimeter and Monte Carlo simulation. Background: High Z materials absorb X-ray remarkably. Among Nano-science, Zinc Oxide nanoparticles are interesting semiconductors, producing reactive oxygen species when irradiated by photons. Therefore, it seems that dose enhancement originating by incorporating ZnO NPs in irradiated volume would increase the therapeutic ratio. Materials and methods Initially, the PRESAGE dosimeter was fabricated and calibrated. Then Zinc Oxide nanoparticles with an average particle size of about 40 nm were synthesized. At next step, various concentrations of the nanoparticles were incorporated into the PRESAGE composition and irradiated in radiation fields. Then, the mentioned processes were simulated. Results: Practical measurements revealed that by incorporating 500, 1000 and 3000 μg ml−1 ZnO NPs into PRESAGE the dose enhancement factor of 1.36, 1.39, 1.44 for 1 × 1 cm 2 field size, 1.39, 1.41, 1.46 for 2 × 2 cm 2 and 1.40, 1.45 and 1.50 for 3 × 3 cm 2 could be found, respectively. Simulation results showed that in the mentioned condition, the dose enhancement factor of 1.05, 1.08, 1.10 for 1 × 1 cm 2 field size, 1.06, 1.09, 1.10 for 2 × 2 cm 2 and 1.08, 1.11 and 1.13 for 3 × 3 cm 2 could be derived, respectively. Conclusion: The results of this study showed that dose enhancement increases by increasing concentration of Zinc Oxide nanoparticles. Many reasons such as photoelectric, pair production effects and even Compton scattering can cause dose enhancement for megavoltage beams.
- 27 April 2020
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 25 (4) , 515-520
Enhanced dose measurement of zinc oxide nanoparticles by radiochromic polymer dosimeter and Monte Carlo simulation
Aim: The aim of this study is to evaluate the effects of Zinc Oxide nanoparticles on dose enhancement factor using PRESAGE dosimeter and Monte Carlo simulation. Background: High Z materials absorb X-ray remarkably. Among Nano-science, Zinc Oxide nanoparticles are interesting semiconductors, producing reactive oxygen species when irradiated by photons. Therefore, it seems that dose enhancement originating by incorporating ZnO NPs in irradiated volume would increase the therapeutic ratio. Materials and methods Initially, the PRESAGE dosimeter was fabricated and calibrated. Then Zinc Oxide nanoparticles with an average particle size of about 40 nm were synthesized. At next step, various concentrations of the nanoparticles were incorporated into the PRESAGE composition and irradiated in radiation fields. Then, the mentioned processes were simulated. Results: Practical measurements revealed that by incorporating 500, 1000 and 3000 μg ml−1 ZnO NPs into PRESAGE the dose enhancement factor of 1.36, 1.39, 1.44 for 1 × 1 cm 2 field size, 1.39, 1.41, 1.46 for 2 × 2 cm 2 and 1.40, 1.45 and 1.50 for 3 × 3 cm 2 could be found, respectively. Simulation results showed that in the mentioned condition, the dose enhancement factor of 1.05, 1.08, 1.10 for 1 × 1 cm 2 field size, 1.06, 1.09, 1.10 for 2 × 2 cm 2 and 1.08, 1.11 and 1.13 for 3 × 3 cm 2 could be derived, respectively. Conclusion: The results of this study showed that dose enhancement increases by increasing concentration of Zinc Oxide nanoparticles. Many reasons such as photoelectric, pair production effects and even Compton scattering can cause dose enhancement for megavoltage beams.
- 9 August 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (1) , 259-269
Determination of geometric accuracy of radiotherapy fields by port film and DRR using Matlab graphical user interface
The purpose of this study is to determine and verify the exact location of radiation therapy fields by using port-film and digital reconstruction radiograph (DRR) as a low-cost tool. Initially, an appropriate algorithm was written for the application of port film in the megavoltage beam irradiation. Detectable contrast was created for the image and then by using appropriate markers and developed written program by MATLAB as DRrPortRegistartion. Semi-automatic and automatic registration between port-film and DRR images were performed for pelvic and chest phantoms. Then, results were compared with electronic portal imaging device (EPID) images in similar conditions. By using this software, DRR and port film as treatment verification tools, the precision of treatment verification and the accuracy of radiation therapy fields were achieved in the extent of the millimeter. Validation results with EPID demonstrated that the mean absolute average error in angle is equal to 0.59 degrees, 1.70 mm in the X-direction, and 2.42 mm in the Y-direction. The results of this study illustrated that using this software and suitable low-cost hardware in the machines without EPID can increase the precision of treatment verification to the millimeter and it can be introduced as a suitable alternative for EPID in centers for increasing treatment accuracy.
- 9 August 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (1) , 259-269
Determination of geometric accuracy of radiotherapy fields by port film and DRR using Matlab graphical user interface
The purpose of this study is to determine and verify the exact location of radiation therapy fields by using port-film and digital reconstruction radiograph (DRR) as a low-cost tool. Initially, an appropriate algorithm was written for the application of port film in the megavoltage beam irradiation. Detectable contrast was created for the image and then by using appropriate markers and developed written program by MATLAB as DRrPortRegistartion. Semi-automatic and automatic registration between port-film and DRR images were performed for pelvic and chest phantoms. Then, results were compared with electronic portal imaging device (EPID) images in similar conditions. By using this software, DRR and port film as treatment verification tools, the precision of treatment verification and the accuracy of radiation therapy fields were achieved in the extent of the millimeter. Validation results with EPID demonstrated that the mean absolute average error in angle is equal to 0.59 degrees, 1.70 mm in the X-direction, and 2.42 mm in the Y-direction. The results of this study illustrated that using this software and suitable low-cost hardware in the machines without EPID can increase the precision of treatment verification to the millimeter and it can be introduced as a suitable alternative for EPID in centers for increasing treatment accuracy.