Abstract
A comparison of retrieved total column ozone amounts TCO between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado NOAA building. This paper, part of an ongoing study, covers a one-year period starting on 17 December 2013. Both the standard Dobson and Pandora total column ozone TCO retrievals required a correction TCOcorr = TCO (1+C(T)) using the effective climatology derived ozone temperature T to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T) are CPandora = 0.00333(T−225) and CDobson = −0.0013 (T−226.7) per K. After the applied corrections removed the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r2 = 0.97 and an average offset of 1.1 ± 5.8 DU. In addition, the Pandora data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).Keywords
All Related Versions
- Published version: Atmospheric Measurement Techniques, 8 (8), 3407.
Funding Information
- Goddard Space Flight Center (NNH09ZDA001N‐EV1)
This publication has 17 references indexed in Scilit:
- Performance of the Ozone Mapping and Profiler Suite (OMPS) productsJournal of Geophysical Research: Atmospheres, 2014
- A comparison of 40 years of SBUV measurements of column ozone with data from the Dobson/Brewer networkJournal of Geophysical Research: Atmospheres, 2013
- NO2 column amounts from ground‐based Pandora and MFDOAS spectrometers using the direct‐sun DOAS technique: Intercomparisons and application to OMI validationJournal of Geophysical Research: Atmospheres, 2009
- Measurements of O 3 , SO 2 , NO 2 and HCHO column amounts using a Brewer spectrometer2005
- Bias in Dobson total ozone measurements at high latitudes due to approximations in calculations of ozone absorption coefficients and air massJournal of Geophysical Research: Atmospheres, 2005
- Version 2 data of the National Science Foundation's Ultraviolet Radiation Monitoring Network: South PoleJournal of Geophysical Research: Atmospheres, 2004
- Effective Bass‐Paur 1985 ozone absorption coefficients for use with Dobson ozone spectrophotometersJournal of Geophysical Research: Atmospheres, 1993
- Locally Weighted Regression: An Approach to Regression Analysis by Local FittingJournal of the American Statistical Association, 1988
- Dobson spectrophotometer total ozone measurement errors caused by interfering absorbing species such as SO2, NO2, and photochemically produced O3 in polluted airGeophysical Research Letters, 1980
- Forty Years’ Research on Atmospheric Ozone at Oxford: a HistoryApplied Optics, 1968