Robert Evans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Robert Evans has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Irina Petropavlovskikh
Cooperative Institute for Research in Environmental Sciences (CIRES), The University of Colorado, Boulder, CO, USA
10 shared publications - Glen McConville
Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO 80309, USA
4 shared publications - Jay R. Herman
Goddard Earth Sciences Technology and Research-2 (GESTAR-2) University of Maryland Baltimore County, Baltimore Maryland, USA
4 shared publications Koji Miyagawa
Visitor with NOAA/ESRL, Global Monitoring Division, Boulder, CO 80305, USA
3 shared publicationsA. Cede
Goddard Earth Sciences Technology & Research (GESTAR) Columbia, Columbia, MD 21046, USA
2 shared publicationsA. Pazmiño
UPMC Université Paris 06, Université Versailles-Saint-Quentin, UMR 8190, LATMOS-IPSL, CNRS/INSU, Paris, France
2 shared publications
Latest Publications
- Open Access
- 18 January 2019
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 12 (1) , 327-343
The effect of instrumental stray light on Brewer and Dobson total ozone measurements
Dobson and Brewer spectrophotometers are the primary, standard instruments for ground-based ozone measurements under the World Meteorological Organization's (WMO) Global Atmosphere Watch program. The accuracy of the data retrieval for both instruments depends on a knowledge of the ozone absorption coefficients and some assumptions underlying the data analysis. Instrumental stray light causes nonlinearity in the response of both the Brewer and Dobson to ozone at large ozone slant paths. In addition, it affects the effective ozone absorption coefficients and extraterrestrial constants that are both instrument-dependent. This effect has not been taken into account in the calculation of ozone absorption coefficients that are currently recommended by WMO for the Dobson network. The ozone absorption coefficients are calculated for each Brewer instrument individually, but in the current procedure the effect of stray light is not considered. This study documents the error caused by the effect of stray light in the Brewer and Dobson total ozone measurements using a physical model for each instrument. For the first time, new ozone absorption coefficients are calculated for the Brewer and Dobson instruments, taking into account the stray light effect. The analyses show that the differences detected between the total ozone amounts deduced from Dobson AD and CD pair wavelengths are related to the level of stray light within the instrument. The discrepancy introduced by the assumption of a fixed height for the ozone layer for ozone measurements at high latitude sites is also evaluated. The ozone data collected by two Dobson instruments during the period of December 2008 to December 2014 are compared with ozone data from a collocated double monochromator Brewer spectrophotometer (Mark III). The results illustrate the dependence of Dobson AD and CD pair measurements on stray light.
- 18 January 2019
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 12 (1) , 327-343
Open AccessThe effect of instrumental stray light on Brewer and Dobson total ozone measurements
Dobson and Brewer spectrophotometers are the primary, standard instruments for ground-based ozone measurements under the World Meteorological Organization's (WMO) Global Atmosphere Watch program. The accuracy of the data retrieval for both instruments depends on a knowledge of the ozone absorption coefficients and some assumptions underlying the data analysis. Instrumental stray light causes nonlinearity in the response of both the Brewer and Dobson to ozone at large ozone slant paths. In addition, it affects the effective ozone absorption coefficients and extraterrestrial constants that are both instrument-dependent. This effect has not been taken into account in the calculation of ozone absorption coefficients that are currently recommended by WMO for the Dobson network. The ozone absorption coefficients are calculated for each Brewer instrument individually, but in the current procedure the effect of stray light is not considered. This study documents the error caused by the effect of stray light in the Brewer and Dobson total ozone measurements using a physical model for each instrument. For the first time, new ozone absorption coefficients are calculated for the Brewer and Dobson instruments, taking into account the stray light effect. The analyses show that the differences detected between the total ozone amounts deduced from Dobson AD and CD pair wavelengths are related to the level of stray light within the instrument. The discrepancy introduced by the assumption of a fixed height for the ozone layer for ozone measurements at high latitude sites is also evaluated. The ozone data collected by two Dobson instruments during the period of December 2008 to December 2014 are compared with ozone data from a collocated double monochromator Brewer spectrophotometer (Mark III). The results illustrate the dependence of Dobson AD and CD pair measurements on stray light.
- Open Access
- 1 March 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-29
The Effect of Instrumental Stray Light on Brewer and Dobson Total Ozone Measurements
Dobson and Brewer spectrophotometers are the primary, standard instruments for ground‐based ozone measurements under the World Meteorological Organization’s (WMO) Global Atmosphere Watch program. The accuracy of the data retrieval for both instruments depends on a knowledge of the ozone absorption coefficients and some assumptions underlying the data analysis. Instrumental stray light causes non-linearity in the response of both the Brewer and Dobson to ozone at large ozone slant paths. In addition, it affects the effective ozone absorption coefficients and extraterrestrial constants that are both instrument dependent. This effect has not been taken into account in the calculation of ozone absorption coefficients that are currently recommended by WMO for the Dobson network. The ozone absorption coefficients are calculated for each Brewer instrument individually, but in the current procedure the effect of stray light is not being considered. This study documents the error caused by the effect of stray light in the Brewer and Dobson total ozone measurements using a mathematical model for each instrument. For the first time, new ozone absorption coefficients are calculated for the Brewer and Dobson instruments taking into account the stray light effect. The analyses show that the differences detected between the total ozone amounts deduced from Dobson AD and CD pair wavelengths are related to the level of stray light within the instrument. The error introduced by the assumption of a fixed height for the ozone layer for ozone measurements at high latitude sites is also evaluated. The ozone data collected by three Dobson instruments between 2008 and 2012 are compared with ozone data from a collocated double monochromator Brewer spectrophotometer (Mark III). The results show the dependence of Dobson AD and CD pair measurements on stray light.
- 1 March 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-29
Open AccessThe Effect of Instrumental Stray Light on Brewer and Dobson Total Ozone Measurements
Dobson and Brewer spectrophotometers are the primary, standard instruments for ground‐based ozone measurements under the World Meteorological Organization’s (WMO) Global Atmosphere Watch program. The accuracy of the data retrieval for both instruments depends on a knowledge of the ozone absorption coefficients and some assumptions underlying the data analysis. Instrumental stray light causes non-linearity in the response of both the Brewer and Dobson to ozone at large ozone slant paths. In addition, it affects the effective ozone absorption coefficients and extraterrestrial constants that are both instrument dependent. This effect has not been taken into account in the calculation of ozone absorption coefficients that are currently recommended by WMO for the Dobson network. The ozone absorption coefficients are calculated for each Brewer instrument individually, but in the current procedure the effect of stray light is not being considered. This study documents the error caused by the effect of stray light in the Brewer and Dobson total ozone measurements using a mathematical model for each instrument. For the first time, new ozone absorption coefficients are calculated for the Brewer and Dobson instruments taking into account the stray light effect. The analyses show that the differences detected between the total ozone amounts deduced from Dobson AD and CD pair wavelengths are related to the level of stray light within the instrument. The error introduced by the assumption of a fixed height for the ozone layer for ozone measurements at high latitude sites is also evaluated. The ozone data collected by three Dobson instruments between 2008 and 2012 are compared with ozone data from a collocated double monochromator Brewer spectrophotometer (Mark III). The results show the dependence of Dobson AD and CD pair measurements on stray light.
- Open Access
- 11 October 2017
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 17 (19) , 12051-12070
Technical note: The US Dobson station network data record prior to 2015, re-evaluation of NDACC and WOUDC archived records with WinDobson processing software
The United States government has operated Dobson ozone spectrophotometers at various sites, starting during the International Geophysical Year (1 July 1957 to 31 December 1958). A network of stations for long-term monitoring of the total column content (thickness of the ozone layer) of the atmosphere was established in the early 1960s and eventually grew to 16 stations, 14 of which are still operational and submit data to the United States of America's National Oceanic and Atmospheric Administration (NOAA). Seven of these sites are also part of the Network for the Detection of Atmospheric Composition Change (NDACC), an organization that maintains its own data archive. Due to recent changes in data processing software the entire dataset was re-evaluated for possible changes. To evaluate and minimize potential changes caused by the new processing software, the reprocessed data record was compared to the original data record archived in the World Ozone and UV Data Center (WOUDC) in Toronto, Canada. The history of the observations at the individual stations, the instruments used for the NOAA network monitoring at the station, the method for reducing zenith-sky observations to total ozone, and calibration procedures were re-evaluated using data quality control tools built into the new software. At the completion of the evaluation, the new datasets are to be published as an update to the WOUDC and NDACC archives, and the entire dataset is to be made available to the scientific community. The procedure for reprocessing Dobson data and the results of the reanalysis on the archived record are presented in this paper. A summary of historical changes to 14 station records is also provided.
- 11 October 2017
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 17 (19) , 12051-12070
Open AccessTechnical note: The US Dobson station network data record prior to 2015, re-evaluation of NDACC and WOUDC archived records with WinDobson processing software
The United States government has operated Dobson ozone spectrophotometers at various sites, starting during the International Geophysical Year (1 July 1957 to 31 December 1958). A network of stations for long-term monitoring of the total column content (thickness of the ozone layer) of the atmosphere was established in the early 1960s and eventually grew to 16 stations, 14 of which are still operational and submit data to the United States of America's National Oceanic and Atmospheric Administration (NOAA). Seven of these sites are also part of the Network for the Detection of Atmospheric Composition Change (NDACC), an organization that maintains its own data archive. Due to recent changes in data processing software the entire dataset was re-evaluated for possible changes. To evaluate and minimize potential changes caused by the new processing software, the reprocessed data record was compared to the original data record archived in the World Ozone and UV Data Center (WOUDC) in Toronto, Canada. The history of the observations at the individual stations, the instruments used for the NOAA network monitoring at the station, the method for reducing zenith-sky observations to total ozone, and calibration procedures were re-evaluated using data quality control tools built into the new software. At the completion of the evaluation, the new datasets are to be published as an update to the WOUDC and NDACC archives, and the entire dataset is to be made available to the scientific community. The procedure for reprocessing Dobson data and the results of the reanalysis on the archived record are presented in this paper. A summary of historical changes to 14 station records is also provided.
- Open Access
- 27 September 2017
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 10 (9) , 3539-3545
Ozone comparison between Pandora #34, Dobson #061, OMI, and OMPS in Boulder, Colorado, for the period December 2013–December 2016
A one-time-calibrated (in December 2013) Pandora spectrometer instrument (Pan #034) has been compared to a periodically calibrated Dobson spectroradiometer (Dobson #061) co-located in Boulder, Colorado, and compared with two satellite instruments over a 3-year period (December 2013–December 2016). The results show good agreement between Pan #034 and Dobson #061 within their statistical uncertainties. Both records are corrected for ozone retrieval sensitivity to stratospheric temperature variability obtained from the Global Modeling Initiative (GMI) and Modern-Era Retrospective analysis for Research and Applications (MERRA-2) model calculations. Pandora #034 and Dobson #061 differ by an average of 2.1 ± 3.2 % when both instruments use their standard ozone absorption cross sections in the retrieval algorithms. The results show a relative drift (0.2 ± 0.08 % yr−1) between Pandora observations against NOAA Dobson in Boulder, CO, over a 3-year period of continuous operation. Pandora drifts relative to the satellite Ozone Monitoring Instrument (OMI) and the Ozone Mapping Profiler Suite (OMPS) are +0.18 ± 0.2 % yr−1 and −0.18 ± 0.2 % yr−1, respectively, where the uncertainties are 2 standard deviations. The drift between Dobson #061 and OMPS for a 5.5-year period (January 2012–June 2017) is −0.07 ± 0.06 % yr−1.
- 27 September 2017
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 10 (9) , 3539-3545
Open AccessOzone comparison between Pandora #34, Dobson #061, OMI, and OMPS in Boulder, Colorado, for the period December 2013–December 2016
A one-time-calibrated (in December 2013) Pandora spectrometer instrument (Pan #034) has been compared to a periodically calibrated Dobson spectroradiometer (Dobson #061) co-located in Boulder, Colorado, and compared with two satellite instruments over a 3-year period (December 2013–December 2016). The results show good agreement between Pan #034 and Dobson #061 within their statistical uncertainties. Both records are corrected for ozone retrieval sensitivity to stratospheric temperature variability obtained from the Global Modeling Initiative (GMI) and Modern-Era Retrospective analysis for Research and Applications (MERRA-2) model calculations. Pandora #034 and Dobson #061 differ by an average of 2.1 ± 3.2 % when both instruments use their standard ozone absorption cross sections in the retrieval algorithms. The results show a relative drift (0.2 ± 0.08 % yr−1) between Pandora observations against NOAA Dobson in Boulder, CO, over a 3-year period of continuous operation. Pandora drifts relative to the satellite Ozone Monitoring Instrument (OMI) and the Ozone Mapping Profiler Suite (OMPS) are +0.18 ± 0.2 % yr−1 and −0.18 ± 0.2 % yr−1, respectively, where the uncertainties are 2 standard deviations. The drift between Dobson #061 and OMPS for a 5.5-year period (January 2012–June 2017) is −0.07 ± 0.06 % yr−1.
- Open Access
- 23 May 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-13
Ozone Comparison between Pandora #34, Dobson #061, OMI, and OMPS at Boulder Colorado for the period December 2013–December 2016
A co-located Pandora Spectrometer Instrument (Pan #034) has been compared to a well calibrated Dobson spectroradiometer (Dobson #061) in Boulder, Colorado and with two satellite instruments over a 3-year period. The results show good agreement between Pan#034 and Dobson #061 within their statistical uncertainties after both records are corrected for ozone retrieval sensitivity to stratospheric temperature variability obtained from the Global Modeling Initiative (GMI) and Modern-Era Retrospective analysis for Research and Applications (MERRA2) model calculations. Pandora#034 and Dobson#061 differ by an average of 2.2 % when both instruments use their standard ozone absorption cross sections in the retrievals algorithms. The results demonstrate the stability of Pandora observations against NOAA Dobson in Boulder, CO over a three year period of continuous operation. The relative drift between two systems is 0.6 % per year.
- 23 May 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-13
Open AccessOzone Comparison between Pandora #34, Dobson #061, OMI, and OMPS at Boulder Colorado for the period December 2013–December 2016
A co-located Pandora Spectrometer Instrument (Pan #034) has been compared to a well calibrated Dobson spectroradiometer (Dobson #061) in Boulder, Colorado and with two satellite instruments over a 3-year period. The results show good agreement between Pan#034 and Dobson #061 within their statistical uncertainties after both records are corrected for ozone retrieval sensitivity to stratospheric temperature variability obtained from the Global Modeling Initiative (GMI) and Modern-Era Retrospective analysis for Research and Applications (MERRA2) model calculations. Pandora#034 and Dobson#061 differ by an average of 2.2 % when both instruments use their standard ozone absorption cross sections in the retrievals algorithms. The results demonstrate the stability of Pandora observations against NOAA Dobson in Boulder, CO over a three year period of continuous operation. The relative drift between two systems is 0.6 % per year.
- Open Access
- 8 May 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-32
The US Dobson Station Network Data Record Prior to 2015, Re-evaluation of NDACC and WOUDC archived records with WinDobson processing software
The United States government has operated Dobson Ozone Spectrophotometers at various sites, starting during the International Geophysical Year (July 1, 1957 to December 31, 1958). A network of stations for longterm monitoring of the total column content (thickness of the ozone layer) of the atmosphere was established in the early 1960s, and eventually grew to sixteen stations, fourteen of which are still operational and submit data to the United States of America’s National Oceanic and Atmospheric Administration (NOAA). Seven of these sites are also part of the Network for the Detection of Atmospheric Composition Change (NDACC), an organization that maintains its own data archive. Due to recent changes in data processing software the entire data set was reevaluated for possible changes. To evaluate and minimize potential changes caused by the new processing software, the reprocessed data record was compared to the original data record archived in the World Ozone and UV Data Center (WOUDC) in Toronto, Canada. The history of the observations at the individual stations, the instruments used for the NOAA network monitoring at the station, the method for reducing zenith sky observations to total ozone, and calibration procedures were re-evaluated using data quality control tools built into the new software. At the completion of the evaluation, the new data sets are to be published as an update to the WOUDC and NDACC archives, and the entire data set is to be made available to the scientific community. The procedure for reprocessing Dobson data and the results of the re-analysis on the archived record is presented in this paper. A summary of historical changes to fourteen station records is also provided.
- 8 May 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-32
Open AccessThe US Dobson Station Network Data Record Prior to 2015, Re-evaluation of NDACC and WOUDC archived records with WinDobson processing software
The United States government has operated Dobson Ozone Spectrophotometers at various sites, starting during the International Geophysical Year (July 1, 1957 to December 31, 1958). A network of stations for longterm monitoring of the total column content (thickness of the ozone layer) of the atmosphere was established in the early 1960s, and eventually grew to sixteen stations, fourteen of which are still operational and submit data to the United States of America’s National Oceanic and Atmospheric Administration (NOAA). Seven of these sites are also part of the Network for the Detection of Atmospheric Composition Change (NDACC), an organization that maintains its own data archive. Due to recent changes in data processing software the entire data set was reevaluated for possible changes. To evaluate and minimize potential changes caused by the new processing software, the reprocessed data record was compared to the original data record archived in the World Ozone and UV Data Center (WOUDC) in Toronto, Canada. The history of the observations at the individual stations, the instruments used for the NOAA network monitoring at the station, the method for reducing zenith sky observations to total ozone, and calibration procedures were re-evaluated using data quality control tools built into the new software. At the completion of the evaluation, the new data sets are to be published as an update to the WOUDC and NDACC archives, and the entire data set is to be made available to the scientific community. The procedure for reprocessing Dobson data and the results of the re-analysis on the archived record is presented in this paper. A summary of historical changes to fourteen station records is also provided.
- Open Access
- 24 August 2015
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 8 (8) , 3407-3418
Comparison of ozone retrievals from the Pandora spectrometer system and Dobson spectrophotometer in Boulder, Colorado
A comparison of retrieved total column ozone (TCO) amounts between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado, NOAA building. This paper, part of an ongoing study, covers a 1-year period starting on 17 December 2013. Both the standard Dobson and Pandora TCO retrievals required a correction, TCOcorr = TCO (1 + C(T)), using a monthly varying effective ozone temperature, TE, derived from a temperature and ozone profile climatology. The correction is used to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(TE) are CPandora = 0.00333(TE-225) and CDobson = -0.0013(TE-226.7) per degree K. After the applied corrections removed most of the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1 % for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r2 = 0.97 and an average offset of 1.1 ± 5.8 DU. In addition, the Pandora TCO data showed 0.3 % annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1 % annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).
- 24 August 2015
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 8 (8) , 3407-3418
Open AccessComparison of ozone retrievals from the Pandora spectrometer system and Dobson spectrophotometer in Boulder, Colorado
A comparison of retrieved total column ozone (TCO) amounts between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado, NOAA building. This paper, part of an ongoing study, covers a 1-year period starting on 17 December 2013. Both the standard Dobson and Pandora TCO retrievals required a correction, TCOcorr = TCO (1 + C(T)), using a monthly varying effective ozone temperature, TE, derived from a temperature and ozone profile climatology. The correction is used to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(TE) are CPandora = 0.00333(TE-225) and CDobson = -0.0013(TE-226.7) per degree K. After the applied corrections removed most of the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1 % for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r2 = 0.97 and an average offset of 1.1 ± 5.8 DU. In addition, the Pandora TCO data showed 0.3 % annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1 % annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).
- Open Access
- 20 March 2015
- Published by Copernicus GmbH in EGUsphere
Comparison of ozone retrievals from the Pandora spectrometer system and Dobson spectrophotometer in Boulder, Colorado
A comparison of retrieved total column ozone amounts TCO between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado NOAA building. This paper, part of an ongoing study, covers a one-year period starting on 17 December 2013. Both the standard Dobson and Pandora total column ozone TCO retrievals required a correction TCOcorr = TCO (1+C(T)) using the effective climatology derived ozone temperature T to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T) are CPandora = 0.00333(T−225) and CDobson = −0.0013 (T−226.7) per K. After the applied corrections removed the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r2 = 0.97 and an average offset of 1.1 ± 5.8 DU. In addition, the Pandora data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).
- 20 March 2015
- Published by Copernicus GmbH in EGUsphere
Open AccessComparison of ozone retrievals from the Pandora spectrometer system and Dobson spectrophotometer in Boulder, Colorado
A comparison of retrieved total column ozone amounts TCO between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado NOAA building. This paper, part of an ongoing study, covers a one-year period starting on 17 December 2013. Both the standard Dobson and Pandora total column ozone TCO retrievals required a correction TCOcorr = TCO (1+C(T)) using the effective climatology derived ozone temperature T to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T) are CPandora = 0.00333(T−225) and CDobson = −0.0013 (T−226.7) per K. After the applied corrections removed the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r2 = 0.97 and an average offset of 1.1 ± 5.8 DU. In addition, the Pandora data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).
- Open Access
- 13 February 2015
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 15 (3) , 1585-1598
The influence of the North Atlantic Oscillation and El Niño–Southern Oscillation on mean and extreme values of column ozone over the United States
Continuous measurements of total ozone (by Dobson spectrophotometers) across the contiguous United States began in the early 1960s. Here, we analyze temporal and spatial variability and trends in total ozone from the five US sites with long-term records. While similar long-term ozone changes are detected at all five sites, we find differences in the patterns of ozone variability on shorter timescales. In addition to standard evaluation techniques, STL-decomposition methods (Seasonal Trend decomposition of time series based on LOESS (LOcally wEighted Scatterplot Smoothing)) are used to address temporal variability and "fingerprints" of dynamical features in the Dobson data. Methods from statistical extreme value theory (EVT) are used to characterize days with high and low total ozone (termed EHOs and ELOs, respectively) at each station and to analyze temporal changes in the frequency of ozone extremes and their relationship to dynamical features such as the North Atlantic Oscillation (NAO) and El Niño–Southern Oscillation. A comparison of the fingerprints detected in the frequency distribution of the extremes with those for standard metrics (i.e., the mean) shows that more fingerprints are found for the extremes, particularly for the positive phase of the NAO, at all five US monitoring sites. Results from the STL decomposition support the findings of the EVT analysis. Finally, we analyze the relative influence of low- and high-ozone events on seasonal mean column ozone at each station. The results show that the influence of ELOs and EHOs on seasonal mean column ozone can be as much as ±5 %, about as large as the overall long-term decadal ozone trends.
- 13 February 2015
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 15 (3) , 1585-1598
Open AccessThe influence of the North Atlantic Oscillation and El Niño–Southern Oscillation on mean and extreme values of column ozone over the United States
Continuous measurements of total ozone (by Dobson spectrophotometers) across the contiguous United States began in the early 1960s. Here, we analyze temporal and spatial variability and trends in total ozone from the five US sites with long-term records. While similar long-term ozone changes are detected at all five sites, we find differences in the patterns of ozone variability on shorter timescales. In addition to standard evaluation techniques, STL-decomposition methods (Seasonal Trend decomposition of time series based on LOESS (LOcally wEighted Scatterplot Smoothing)) are used to address temporal variability and "fingerprints" of dynamical features in the Dobson data. Methods from statistical extreme value theory (EVT) are used to characterize days with high and low total ozone (termed EHOs and ELOs, respectively) at each station and to analyze temporal changes in the frequency of ozone extremes and their relationship to dynamical features such as the North Atlantic Oscillation (NAO) and El Niño–Southern Oscillation. A comparison of the fingerprints detected in the frequency distribution of the extremes with those for standard metrics (i.e., the mean) shows that more fingerprints are found for the extremes, particularly for the positive phase of the NAO, at all five US monitoring sites. Results from the STL decomposition support the findings of the EVT analysis. Finally, we analyze the relative influence of low- and high-ozone events on seasonal mean column ozone at each station. The results show that the influence of ELOs and EHOs on seasonal mean column ozone can be as much as ±5 %, about as large as the overall long-term decadal ozone trends.
- Open Access
- 12 February 2014
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 14 (3) , 1635-1648
Evaluation of the use of five laboratory-determined ozone absorption cross sections in Brewer and Dobson retrieval algorithms
The primary ground-based instruments used to report total column ozone (TOC) are Brewer and Dobson spectrophotometers in separate networks. These instruments make measurements of the UV irradiances, and through a well-defined process, a TOC value is produced. Inherent to the algorithm is the use of a laboratory-determined cross-section data set. We used five ozone cross-section data sets: three data sets that are based on measurements of Bass and Paur; one derived from Daumont, Brion and Malicet (DBM); and a new set determined by Institute of Experimental Physics (IUP), University of Bremen. The three Bass and Paur (1985) sets are as follows: quadratic temperature coefficients from the IGACO (a glossary is provided in Appendix A) web page (IGQ4), the Brewer network operational calibration set (BOp), and the set used by Bernhard et al. (2005) in the reanalysis of the Dobson absorption coefficient values (B05). The ozone absorption coefficients for Brewer and Dobson instruments are then calculated using the normal Brewer operative method, which is essentially the same as that used for Dobson instruments. Considering the standard TOC algorithm for the Brewer instruments and comparing to the Brewer standard operational calibration data set, using the slit functions for the individual instruments, we find the IUP data set changes the calculated TOC by −0.5%, the DBM data set changes the calculated TOC by −3.2%, and the IGQ4 data set at −45 °C changes the calculated TOC by +1.3%. Considering the standard algorithm for the Dobson instruments, and comparing to results using the official 1992 ozone absorption coefficients values and the single set of slit functions defined for all Dobson instruments, the calculated TOC changes by +1%, with little variation depending on which data set is used. We applied the changes to the European Dobson and Brewer reference instruments during the Izaña 2012 Absolute Calibration Campaign. With the application of a common Langley calibration and the IUP cross section, the differences between Brewer and Dobson data sets vanish, whereas using those of Bass and Paur and DBM produces differences of 1.5 and 2%, respectively. A study of the temperature dependence of these cross-section data sets is presented using the Arosa, Switzerland, total ozone record of 2003–2006, obtained from two Brewer-type instruments and one Dobson-type instrument, combined with the stratospheric ozone and temperature profiles from the Payerne soundings in the same period. The seasonal dependence of the differences between the results from the various instruments is greatly reduced with the application of temperature-dependent absorption coefficients, with the greatest reduction obtained using the IUP data set.
- 12 February 2014
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 14 (3) , 1635-1648
Open AccessEvaluation of the use of five laboratory-determined ozone absorption cross sections in Brewer and Dobson retrieval algorithms
The primary ground-based instruments used to report total column ozone (TOC) are Brewer and Dobson spectrophotometers in separate networks. These instruments make measurements of the UV irradiances, and through a well-defined process, a TOC value is produced. Inherent to the algorithm is the use of a laboratory-determined cross-section data set. We used five ozone cross-section data sets: three data sets that are based on measurements of Bass and Paur; one derived from Daumont, Brion and Malicet (DBM); and a new set determined by Institute of Experimental Physics (IUP), University of Bremen. The three Bass and Paur (1985) sets are as follows: quadratic temperature coefficients from the IGACO (a glossary is provided in Appendix A) web page (IGQ4), the Brewer network operational calibration set (BOp), and the set used by Bernhard et al. (2005) in the reanalysis of the Dobson absorption coefficient values (B05). The ozone absorption coefficients for Brewer and Dobson instruments are then calculated using the normal Brewer operative method, which is essentially the same as that used for Dobson instruments. Considering the standard TOC algorithm for the Brewer instruments and comparing to the Brewer standard operational calibration data set, using the slit functions for the individual instruments, we find the IUP data set changes the calculated TOC by −0.5%, the DBM data set changes the calculated TOC by −3.2%, and the IGQ4 data set at −45 °C changes the calculated TOC by +1.3%. Considering the standard algorithm for the Dobson instruments, and comparing to results using the official 1992 ozone absorption coefficients values and the single set of slit functions defined for all Dobson instruments, the calculated TOC changes by +1%, with little variation depending on which data set is used. We applied the changes to the European Dobson and Brewer reference instruments during the Izaña 2012 Absolute Calibration Campaign. With the application of a common Langley calibration and the IUP cross section, the differences between Brewer and Dobson data sets vanish, whereas using those of Bass and Paur and DBM produces differences of 1.5 and 2%, respectively. A study of the temperature dependence of these cross-section data sets is presented using the Arosa, Switzerland, total ozone record of 2003–2006, obtained from two Brewer-type instruments and one Dobson-type instrument, combined with the stratospheric ozone and temperature profiles from the Payerne soundings in the same period. The seasonal dependence of the differences between the results from the various instruments is greatly reduced with the application of temperature-dependent absorption coefficients, with the greatest reduction obtained using the IUP data set.