Comparison of subjective image analysis and effective dose between low-dose cone-beam computed tomography machines
Open Access
- 1 January 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 52 (2) , 20220176
Abstract
Objectives: To compare the cone-beam computed tomography (CBCT) image quality and effective dose between low-dose scanning and standard manufacturer-recommended protocols among different CBCT units. Methods: Three human-equivalent phantoms were scanned using the ultra-low-dose (ULD), low dose (LD), and standard dose (STD) modes of ProMax 3D Mid (Planmeca Oy, Helsinki, Finland) and Orthophos SL (Sirona, Bensheim, German) for the CBCT images. The quality of the dental anatomical images was assessed by four experienced oral and maxillofacial radiologists using a 5-point Likert scale. OnDemand3D (Cybermed Co., Seoul, Korea) was used as the third-party software for viewing. The percentage of absolute agreement was calculated to determine intra- and interrater agreements among the observers. The effective doses for all CBCT scanning protocols were also calculated. Results: The STD protocol yielded a higher image quality than did the ULD and LD protocols in both ProMax 3D Mid and Orthophos SL. The ULD and LD protocols demonstrated an “acceptable-to-good” sense of visual perception of the CBCT images. The visibility scores significantly differed between the ULD and LD and the STD protocols in ProMax 3D Mid and Orthophos SL, except for the 120-kVp setting in ProMax 3D Mid. The average intra- and interrater agreement scores ranged from 0.63 to 0.89 and from 0.44 to 0.76, respectively. The ULD and LD protocols reduced the radiation dose sixfold compared with the STD protocol. Conclusions: High-tube-voltage protocols could remarkably reduce the imaging dose without degrading the image quality. Specifically, ULD and LD CBCT protocols may be adopted as routine practice for diagnosis and treatment planning.Keywords
This publication has 29 references indexed in Scilit:
- Novel low-dose protocols using cone beam computed tomography in dental medicine: a review focusing on indications, limitations, and future possibilitiesClinical Oral Investigations, 2019
- Cone-beam CT in paediatric dentistry: DIMITRA project position statementPediatric Radiology, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Diagnostic accuracy of 2 cone-beam computed tomography protocols for detecting arthritic changes in temporomandibular jointsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2015
- Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomographyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2013
- Quantification of external root resorption by low- vs high-resolution cone-beam computed tomography and periapical radiography: A volumetric and linear analysisAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2013
- Effective dose range for dental cone beam computed tomography scannersEuropean Journal of Radiology, 2012
- Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applicationsEuropean Journal of Radiology, 2009
- Cone-Beam CT Diagnostic Applications: Caries, Periodontal Bone Assessment, and Endodontic ApplicationsDental Clinics of North America, 2008
- Radiation Protection in MedicineAnnals of the ICRP, 2007