Phattaranant Mahasantipiya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Phattaranant Mahasantipiya has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Arnon Charuakkra
Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand
4 shared publications - Helena Mehtonen
Department of Radiology, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, 33250 Tampere, Finland
2 shared publications - Irina Rinta-Kiikka
Department of Radiology, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, 33250 Tampere, Finland
2 shared publications - Jari Kangas
TAUCHI Research Center, Tampere University, Tampere, Finland
2 shared publications - John Mäkelä
TAUCHI Research Center, Faculty of Information Technology and Communication Sciences, Tampere University, 33100 Tampere, Finland
2 shared publications - Jorma Järnstedt
Department of Radiology, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, Tampere, Finland
2 shared publications
Latest Publications
- Open Access
- 7 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2493
Immersive Virtual Reality for 3D Cephalometric Landmarking Across Low-Dose and Ultra-Low-Dose CBCT: A Pilot Comparison with a Conventional Computer Interface
Background: Three-dimensional cephalometric landmarking provides the spatial reference framework for computer-aided surgical simulation in craniomaxillofacial (CMF) surgery. Conventional workflows rely on two-dimensional computer interfaces (CIs), yet imaging data are inherently volumetric, and repeated CBCT imaging creates pressure to minimise patient radiation exposure. Immersive virtual reality (VR) offers a more intuitive environment for spatial tasks, yet the feasibility of ultra-low-dose (uLD) protocols for cephalometric landmarking in CI and VR remains unevaluated. This pilot study evaluated accuracy, reproducibility and workload across low-dose (LD) and uLD CBCT protocols in both environments. Methods: Four CMF radiologists placed ten 3D cephalometric landmarks on 20 CBCT datasets across three rounds. Round 1 used deep learning-predicted coordinates as ground truth. Rounds 2–3 assessed blind reproducibility. Workload was evaluated using the NASA Task Load Index. Results: Median Round 1 accuracy was 1.00 mm in both environments; mean CI accuracy was 1.05 mm and mean VR accuracy was 2.03 mm after outlier exclusion. Log analysis identified controller slips and software logging errors as a primary VR outlier source (22/793, 2.77%). Reproducibility was higher in CIs; VR medians remained clinically relevant. Dose level had no meaningful effect. The NASA-TLX showed decreasing VR workload across sessions, with AI-guided landmarking associated with the lowest mental demand. Conclusions: VR-based landmarking is feasible: its median accuracy was comparable to that of CIs and radiologists responded positively. Reproducibility was lower in VR, attributable to software constraints rather than the visualisation modality. The uLD protocol performed comparably to LD, supporting dose optimisation. Integration of AI assistance within VR represents the most promising direction for further development.
- 7 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2493
Open AccessImmersive Virtual Reality for 3D Cephalometric Landmarking Across Low-Dose and Ultra-Low-Dose CBCT: A Pilot Comparison with a Conventional Computer Interface
Background: Three-dimensional cephalometric landmarking provides the spatial reference framework for computer-aided surgical simulation in craniomaxillofacial (CMF) surgery. Conventional workflows rely on two-dimensional computer interfaces (CIs), yet imaging data are inherently volumetric, and repeated CBCT imaging creates pressure to minimise patient radiation exposure. Immersive virtual reality (VR) offers a more intuitive environment for spatial tasks, yet the feasibility of ultra-low-dose (uLD) protocols for cephalometric landmarking in CI and VR remains unevaluated. This pilot study evaluated accuracy, reproducibility and workload across low-dose (LD) and uLD CBCT protocols in both environments. Methods: Four CMF radiologists placed ten 3D cephalometric landmarks on 20 CBCT datasets across three rounds. Round 1 used deep learning-predicted coordinates as ground truth. Rounds 2–3 assessed blind reproducibility. Workload was evaluated using the NASA Task Load Index. Results: Median Round 1 accuracy was 1.00 mm in both environments; mean CI accuracy was 1.05 mm and mean VR accuracy was 2.03 mm after outlier exclusion. Log analysis identified controller slips and software logging errors as a primary VR outlier source (22/793, 2.77%). Reproducibility was higher in CIs; VR medians remained clinically relevant. Dose level had no meaningful effect. The NASA-TLX showed decreasing VR workload across sessions, with AI-guided landmarking associated with the lowest mental demand. Conclusions: VR-based landmarking is feasible: its median accuracy was comparable to that of CIs and radiologists responded positively. Reproducibility was lower in VR, attributable to software constraints rather than the visualisation modality. The uLD protocol performed comparably to LD, supporting dose optimisation. Integration of AI assistance within VR represents the most promising direction for further development.
- Open Access
- 17 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 5007
Influence of Cone Beam Computed Tomography Radiation Dose on Image Quality and Usability in Virtual Reality and Traditional Computer Interfaces
Computer-assisted surgical simulation (CASS) in craniomaxillofacial (CMF) surgery is traditionally performed using a computer interface (CI) with a two-dimensional monitor, while the adoption of immersive virtual reality (VR) remains limited. This study examined how low-dose (LD) and high-dose (HD) cone beam computed tomography (CBCT) imaging modes influence image quality and usability across both CI and VR environments. Five CMF radiologists rated CBCT views and 3D-segmented models on a 0–4 Likert scale, and intra- and interobserver agreement was calculated. VR usability was further assessed using the NASA Task Load Index and follow-up interviews. LD imaging performed comparably to HD in both interfaces, with slightly higher scores for CBCT views in LD mode. For 3D models, HD scored marginally higher in CI, whereas LD performed slightly better in VR. Observer agreement ranged from fair to excellent, and VR demonstrated reliability like CI. NASA-TLX results indicated reductions in mental and temporal demand, along with decreased effort and frustration during VR use, suggesting diminishing cognitive and emotional strain over time. In this pilot study, the findings suggest that LD CBCT may be feasible for selected CMF CASS applications and that VR offers an immersive and user-friendly alternative without compromising diagnostic reliability, supporting its potential role in future surgical planning.
- 17 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 5007
Open AccessInfluence of Cone Beam Computed Tomography Radiation Dose on Image Quality and Usability in Virtual Reality and Traditional Computer Interfaces
Computer-assisted surgical simulation (CASS) in craniomaxillofacial (CMF) surgery is traditionally performed using a computer interface (CI) with a two-dimensional monitor, while the adoption of immersive virtual reality (VR) remains limited. This study examined how low-dose (LD) and high-dose (HD) cone beam computed tomography (CBCT) imaging modes influence image quality and usability across both CI and VR environments. Five CMF radiologists rated CBCT views and 3D-segmented models on a 0–4 Likert scale, and intra- and interobserver agreement was calculated. VR usability was further assessed using the NASA Task Load Index and follow-up interviews. LD imaging performed comparably to HD in both interfaces, with slightly higher scores for CBCT views in LD mode. For 3D models, HD scored marginally higher in CI, whereas LD performed slightly better in VR. Observer agreement ranged from fair to excellent, and VR demonstrated reliability like CI. NASA-TLX results indicated reductions in mental and temporal demand, along with decreased effort and frustration during VR use, suggesting diminishing cognitive and emotional strain over time. In this pilot study, the findings suggest that LD CBCT may be feasible for selected CMF CASS applications and that VR offers an immersive and user-friendly alternative without compromising diagnostic reliability, supporting its potential role in future surgical planning.
- Open Access
- 1 January 2023
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 52 (2) , 20220176
Comparison of subjective image analysis and effective dose between low-dose cone-beam computed tomography machines
Objectives: To compare the cone-beam computed tomography (CBCT) image quality and effective dose between low-dose scanning and standard manufacturer-recommended protocols among different CBCT units. Methods: Three human-equivalent phantoms were scanned using the ultra-low-dose (ULD), low dose (LD), and standard dose (STD) modes of ProMax 3D Mid (Planmeca Oy, Helsinki, Finland) and Orthophos SL (Sirona, Bensheim, German) for the CBCT images. The quality of the dental anatomical images was assessed by four experienced oral and maxillofacial radiologists using a 5-point Likert scale. OnDemand3D (Cybermed Co., Seoul, Korea) was used as the third-party software for viewing. The percentage of absolute agreement was calculated to determine intra- and interrater agreements among the observers. The effective doses for all CBCT scanning protocols were also calculated. Results: The STD protocol yielded a higher image quality than did the ULD and LD protocols in both ProMax 3D Mid and Orthophos SL. The ULD and LD protocols demonstrated an “acceptable-to-good” sense of visual perception of the CBCT images. The visibility scores significantly differed between the ULD and LD and the STD protocols in ProMax 3D Mid and Orthophos SL, except for the 120-kVp setting in ProMax 3D Mid. The average intra- and interrater agreement scores ranged from 0.63 to 0.89 and from 0.44 to 0.76, respectively. The ULD and LD protocols reduced the radiation dose sixfold compared with the STD protocol. Conclusions: High-tube-voltage protocols could remarkably reduce the imaging dose without degrading the image quality. Specifically, ULD and LD CBCT protocols may be adopted as routine practice for diagnosis and treatment planning.
- 1 January 2023
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 52 (2) , 20220176
Open AccessComparison of subjective image analysis and effective dose between low-dose cone-beam computed tomography machines
Objectives: To compare the cone-beam computed tomography (CBCT) image quality and effective dose between low-dose scanning and standard manufacturer-recommended protocols among different CBCT units. Methods: Three human-equivalent phantoms were scanned using the ultra-low-dose (ULD), low dose (LD), and standard dose (STD) modes of ProMax 3D Mid (Planmeca Oy, Helsinki, Finland) and Orthophos SL (Sirona, Bensheim, German) for the CBCT images. The quality of the dental anatomical images was assessed by four experienced oral and maxillofacial radiologists using a 5-point Likert scale. OnDemand3D (Cybermed Co., Seoul, Korea) was used as the third-party software for viewing. The percentage of absolute agreement was calculated to determine intra- and interrater agreements among the observers. The effective doses for all CBCT scanning protocols were also calculated. Results: The STD protocol yielded a higher image quality than did the ULD and LD protocols in both ProMax 3D Mid and Orthophos SL. The ULD and LD protocols demonstrated an “acceptable-to-good” sense of visual perception of the CBCT images. The visibility scores significantly differed between the ULD and LD and the STD protocols in ProMax 3D Mid and Orthophos SL, except for the 120-kVp setting in ProMax 3D Mid. The average intra- and interrater agreement scores ranged from 0.63 to 0.89 and from 0.44 to 0.76, respectively. The ULD and LD protocols reduced the radiation dose sixfold compared with the STD protocol. Conclusions: High-tube-voltage protocols could remarkably reduce the imaging dose without degrading the image quality. Specifically, ULD and LD CBCT protocols may be adopted as routine practice for diagnosis and treatment planning.
- 1 February 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (2) , 20160253
Infection control and patient discomfort with an alternative plastic barrier in intraoral digital radiography
(1) To compare the efficacy of a commercially available hygienic sheath and an alternative plastic bag in preventing contamination of the imaging plate during intraoral radiography and (2) to compare patient discomfort when using the hygienic sheath and the plastic bag. 60 sterilized Size 2 imaging plates covered with either the hygienic sheath (n = 30) or the plastic bag (n = 30) were used to simulate digital periapical radiographic examination in 30 volunteer patients. After disinfection, each plate was swabbed. The swabbed medium was then plated on trypticase soy agar and incubated. Bacterial colonies were counted. Patient discomfort was assessed using a visual analogue scale (VAS) score. The comparison of the number of bacterial colonies and VAS scores between the two groups was tested by paired t-test at p < 0.05. There was no significant difference in the number of bacterial colonies between the two groups (p = 0.745). Of all the plates, 10% plates yielded bacterial colonies. The mean count of bacterial colonies for both groups was 10–20 CFU ml−1. However, there was a significant difference between VAS scores for the two systems (p = 0.000). The mean VAS scores (range 0–10) for patient discomfort for the hygienic sheath group and the plastic bag group were 3.03 and 5.33, respectively. Based on the design of this study, the alternative barrier provided similar results to those commercially available. Regarding the type of barrier envelope, the hygienic sheath induced less discomfort than the plastic bag.
- 1 February 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (2) , 20160253
Infection control and patient discomfort with an alternative plastic barrier in intraoral digital radiography
(1) To compare the efficacy of a commercially available hygienic sheath and an alternative plastic bag in preventing contamination of the imaging plate during intraoral radiography and (2) to compare patient discomfort when using the hygienic sheath and the plastic bag. 60 sterilized Size 2 imaging plates covered with either the hygienic sheath (n = 30) or the plastic bag (n = 30) were used to simulate digital periapical radiographic examination in 30 volunteer patients. After disinfection, each plate was swabbed. The swabbed medium was then plated on trypticase soy agar and incubated. Bacterial colonies were counted. Patient discomfort was assessed using a visual analogue scale (VAS) score. The comparison of the number of bacterial colonies and VAS scores between the two groups was tested by paired t-test at p < 0.05. There was no significant difference in the number of bacterial colonies between the two groups (p = 0.745). Of all the plates, 10% plates yielded bacterial colonies. The mean count of bacterial colonies for both groups was 10–20 CFU ml−1. However, there was a significant difference between VAS scores for the two systems (p = 0.000). The mean VAS scores (range 0–10) for patient discomfort for the hygienic sheath group and the plastic bag group were 3.03 and 5.33, respectively. Based on the design of this study, the alternative barrier provided similar results to those commercially available. Regarding the type of barrier envelope, the hygienic sheath induced less discomfort than the plastic bag.
- Open Access
- 1 January 2013
- Published by Korean Academy of Oral and Maxillofacial Radiology in Imaging Science in Dentistry
- Vol. 43 (4) , 289-293
Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients
Mahasantipiya PM, et al. Imaging Sci Dent. 2013 Dec;43(4):289-293. https://doi.org/10.5624/isd.2013.43.4.289
- 1 January 2013
- Published by Korean Academy of Oral and Maxillofacial Radiology in Imaging Science in Dentistry
- Vol. 43 (4) , 289-293
Open AccessImage analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients
Mahasantipiya PM, et al. Imaging Sci Dent. 2013 Dec;43(4):289-293. https://doi.org/10.5624/isd.2013.43.4.289