Impella preserves haemodynamics with adequate stressed blood volume and normal pulmonary vascular resistance in a goat model of ventricular fibrillation
Open Access
- 18 December 2025
- journal article
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (1)
Abstract
Aims: Ventricular fibrillation (VF) is a frequent and life-threatening complication of acute myocardial infarction. Although the Impella device provides circulatory support solely to the left ventricle (LV), emerging reports have suggested that it may partially maintain haemodynamics even during VF. This study sought to examine this phenomenon under controlled experimental conditions. Methods and results: In eight Saanen goats, we recorded right atrial pressure (RAP), left atrial pressure (LAP), arterial pressure (AP), LV pressure, pulmonary artery flow (PAF), carotid artery flow (CAF), and coronary flow (CoF). We inserted an Impella CP and induced VF using direct current. In Protocol 1, we changed the stressed blood volume (SBV) by blood withdrawal/infusion or pulmonary vascular resistance (PVR) by pulmonary microembolisation and measured the haemodynamics during VF with Impella P4 support (n = 1 each). In Protocol 2 (n = 6), we compared the central and peripheral blood flows between the baseline conditions and three Impella support levels (P0, P4, and P8) during VF. In Protocol 2, an increase of Impella support to P4 and P8 during VF significantly increased AP in a support level-dependent manner (P0, P4, and P8: 26.5 ± 2.5, 57.7 ± 8.7 and 72.0 ± 15.3 mmHg, respectively; P < 0.001) while lowering RAP and LAP. Impella partially maintained PAF (0, 1.2 ± 0.6 and 1.6 ± 0.9 L/min; P = 0.011), CAF (0, 177.6 ± 26.3 and 235.5 ± 44.1 mL/min; P < 0.001), and CoF (0, 68.5 ± 32.0 and 57.8 ± 20.6 mL/min; P = 0.002) during VF. Conclusion: Impella preserved systemic, cerebral, and coronary blood flow with adequate SBV and normal PVR conditions in a goat model of VF.Keywords
Funding Information
- Department of Cardiovascular Dynamics
- National Cerebral and Cardiovascular Center
- Grant-in-Aid for Scientific Research
- JSPS
- KAKENHI (25K12264)
- KAKENHI (25K22628)
- KAKENHI (25K12304)
- Japan Agency for Medical Research and Development (23hk0102085h0002)
- Japan Agency for Medical Research and Development (23uk1024007h0001)
- Ministry of Internal Affairs and Communications (JP225006004)
- Intramural Research Fund for Cardiovascular Diseases of National Cerebral and Cardiovascular Center (JPMJPF2018)
- ABIOMED, Inc.
- NTT-Research, Inc
This publication has 21 references indexed in Scilit:
- High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirementJournal of Artificial Organs, 2015
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Population Trends in the Incidence and Outcomes of Acute Myocardial InfarctionNew England Journal of Medicine, 2010
- Factors influencing early and late outcome following the Fontan procedure in the current era. The ‘Two Commandments’?☆European Journal of Cardio-Thoracic Surgery, 2007
- A novel framework of circulatory equilibriumAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Effects of positive pressure ventilation and inspired oxygen on pulmonary vascular resistance and tissue oxygen delivery in neonatal pigsCardiology in the Young, 1998
- Coronary perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitationJAMA, 1990
- Hypoxic pulmonary vasoconstriction and pulmonary gas exchange in normal manRespiration Physiology, 1987
- Prognostic and therapeutic importance of the aortic diastolic pressure in resuscitation from cardiac arrestCritical Care Medicine, 1984
- Pulmonary vascular resistance correlates in intact normal and abnormal canine lungsCritical Care Medicine, 1982