Takuya Nishikawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takuya Nishikawa has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Keita Saku
National Cerebral and Cardiovascular Center
22 shared publications Kenji Sunagawa
Circulatory System Research Foundation
17 shared publicationsTakuya Kishi
Department of Fukuoka Health and Welfare Sciences, International University of Health and Welfare , Okawa
13 shared publicationsHiroyuki Tsutsui
Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kyushu University , Fukuoka
12 shared publications- Toru Kawada
National Cerebral and Cardiovascular Center
11 shared publications Takeshi Tohyama
Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kyushu University , Fukuoka
10 shared publications
Latest Publications
- 10 October 2026
- Published by Springer Nature
- p. 265-272
Development of a Patient-Specific Cardiovascular Simulator for Tailored Cardiovascular Management
- 10 October 2026
- Published by Springer Nature
- p. 265-272
Development of a Patient-Specific Cardiovascular Simulator for Tailored Cardiovascular Management
- Open Access
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (8) , 2695-2708
Modeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework
This study develops a model-based control framework integrating a left ventricular assist device (LVAD) with drug therapy to regulate multidimensional hemodynamics (mean arterial pressure, cardiac output, and left and right atrial pressures) while minimizing myocardial oxygen consumption ($MVO\_{2}$) in acute heart afailure (AHF). By modeling the hemodynamic and $MVO\_{2}$ effects of partial and total LVAD support, the framework enables combined drugs-LVAD therapy for severe AHF cases where drug therapy alone is not effective. A previously developed hemodynamic control framework was extended to incorporate LVAD support. Using circulatory equilibrium models under LVAD support, an analytical $MVO\_{2}$ model encompassing both LVAD modes was derived from the relationship between $MVO\_{2}$ and the ventricular pressure-volume area. An optimal controller explicitly accounts for transitions between partial and total LVAD support. In our cardiovascular simulator, we validated the $MVO_{2}$ model and evaluated the framework's multidimensional hemodynamic regulation and $MVO\_{2}$ minimization capabilities. The $MVO\_{2}$ model accurately predicted $MVO\_{2}$ across the two LVAD modes. In a severe AHF scenario, drug therapy or LVAD support alone failed, whereas the combined drugs-LVAD controller succeeded in achieving both hemodynamic regulation and $MVO\_{2}$ minimization. Compared with drug therapy alone, drugs-LVAD control using the proposed $MVO\_{2}$ model halved $MVO\_{2}$ while achieving multidimensional regulation. Our drugs-LVAD framework may enable multidimensional hemodynamic regulation while reducing $MVO\_{2}$ in severe AHF. Modeling both partial and total LVAD support may be essential for hemodynamic management. This work provides a theoretical basis for integrated drugs-LVAD control to achieve target hemodynamics while reducing cardiac workload.- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (8) , 2695-2708
Open AccessModeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework
This study develops a model-based control framework integrating a left ventricular assist device (LVAD) with drug therapy to regulate multidimensional hemodynamics (mean arterial pressure, cardiac output, and left and right atrial pressures) while minimizing myocardial oxygen consumption ($MVO\_{2}$) in acute heart afailure (AHF). By modeling the hemodynamic and $MVO\_{2}$ effects of partial and total LVAD support, the framework enables combined drugs-LVAD therapy for severe AHF cases where drug therapy alone is not effective. A previously developed hemodynamic control framework was extended to incorporate LVAD support. Using circulatory equilibrium models under LVAD support, an analytical $MVO\_{2}$ model encompassing both LVAD modes was derived from the relationship between $MVO\_{2}$ and the ventricular pressure-volume area. An optimal controller explicitly accounts for transitions between partial and total LVAD support. In our cardiovascular simulator, we validated the $MVO_{2}$ model and evaluated the framework's multidimensional hemodynamic regulation and $MVO\_{2}$ minimization capabilities. The $MVO\_{2}$ model accurately predicted $MVO\_{2}$ across the two LVAD modes. In a severe AHF scenario, drug therapy or LVAD support alone failed, whereas the combined drugs-LVAD controller succeeded in achieving both hemodynamic regulation and $MVO\_{2}$ minimization. Compared with drug therapy alone, drugs-LVAD control using the proposed $MVO\_{2}$ model halved $MVO\_{2}$ while achieving multidimensional regulation. Our drugs-LVAD framework may enable multidimensional hemodynamic regulation while reducing $MVO\_{2}$ in severe AHF. Modeling both partial and total LVAD support may be essential for hemodynamic management. This work provides a theoretical basis for integrated drugs-LVAD control to achieve target hemodynamics while reducing cardiac workload. - 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (4) , H1241-H1256
Understanding the hemodynamic effects of milrinone in normal and failing hearts: an experimental study using the circulatory equilibrium framework in canines
Analysis using a generalized circulatory equilibrium framework demonstrates that milrinone reduces stressed blood volume, shifting the venous return curve downward in both normal and heart failure (HF) models. In contrast, milrinone shifts the cardiac output (CO) curve upward only in the HF model. Left atrial pressure is reduced without CO reduction in the HF model, whereas CO decreases in the normal model. These findings indicate that circulatory equilibrium responses to milrinone depend on cardiac function.
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (4) , H1241-H1256
Understanding the hemodynamic effects of milrinone in normal and failing hearts: an experimental study using the circulatory equilibrium framework in canines
Analysis using a generalized circulatory equilibrium framework demonstrates that milrinone reduces stressed blood volume, shifting the venous return curve downward in both normal and heart failure (HF) models. In contrast, milrinone shifts the cardiac output (CO) curve upward only in the HF model. Left atrial pressure is reduced without CO reduction in the HF model, whereas CO decreases in the normal model. These findings indicate that circulatory equilibrium responses to milrinone depend on cardiac function.
- Open Access
- 23 January 2026
- Published by Elsevier in International Journal of Cardiology
- Vol. 449, 134192
Impaired atrioventricular time interaction contributes to tachycardia-induced hemodynamic deterioration: In vivo and in silico hybrid approach
- 23 January 2026
- Published by Elsevier in International Journal of Cardiology
- Vol. 449, 134192
Open AccessImpaired atrioventricular time interaction contributes to tachycardia-induced hemodynamic deterioration: In vivo and in silico hybrid approach
- Open Access
- 18 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (1)
Impella preserves haemodynamics with adequate stressed blood volume and normal pulmonary vascular resistance in a goat model of ventricular fibrillation
Aims: Ventricular fibrillation (VF) is a frequent and life-threatening complication of acute myocardial infarction. Although the Impella device provides circulatory support solely to the left ventricle (LV), emerging reports have suggested that it may partially maintain haemodynamics even during VF. This study sought to examine this phenomenon under controlled experimental conditions. Methods and results: In eight Saanen goats, we recorded right atrial pressure (RAP), left atrial pressure (LAP), arterial pressure (AP), LV pressure, pulmonary artery flow (PAF), carotid artery flow (CAF), and coronary flow (CoF). We inserted an Impella CP and induced VF using direct current. In Protocol 1, we changed the stressed blood volume (SBV) by blood withdrawal/infusion or pulmonary vascular resistance (PVR) by pulmonary microembolisation and measured the haemodynamics during VF with Impella P4 support (n = 1 each). In Protocol 2 (n = 6), we compared the central and peripheral blood flows between the baseline conditions and three Impella support levels (P0, P4, and P8) during VF. In Protocol 2, an increase of Impella support to P4 and P8 during VF significantly increased AP in a support level-dependent manner (P0, P4, and P8: 26.5 ± 2.5, 57.7 ± 8.7 and 72.0 ± 15.3 mmHg, respectively; P < 0.001) while lowering RAP and LAP. Impella partially maintained PAF (0, 1.2 ± 0.6 and 1.6 ± 0.9 L/min; P = 0.011), CAF (0, 177.6 ± 26.3 and 235.5 ± 44.1 mL/min; P < 0.001), and CoF (0, 68.5 ± 32.0 and 57.8 ± 20.6 mL/min; P = 0.002) during VF. Conclusion: Impella preserved systemic, cerebral, and coronary blood flow with adequate SBV and normal PVR conditions in a goat model of VF.
- 18 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (1)
Open AccessImpella preserves haemodynamics with adequate stressed blood volume and normal pulmonary vascular resistance in a goat model of ventricular fibrillation
Aims: Ventricular fibrillation (VF) is a frequent and life-threatening complication of acute myocardial infarction. Although the Impella device provides circulatory support solely to the left ventricle (LV), emerging reports have suggested that it may partially maintain haemodynamics even during VF. This study sought to examine this phenomenon under controlled experimental conditions. Methods and results: In eight Saanen goats, we recorded right atrial pressure (RAP), left atrial pressure (LAP), arterial pressure (AP), LV pressure, pulmonary artery flow (PAF), carotid artery flow (CAF), and coronary flow (CoF). We inserted an Impella CP and induced VF using direct current. In Protocol 1, we changed the stressed blood volume (SBV) by blood withdrawal/infusion or pulmonary vascular resistance (PVR) by pulmonary microembolisation and measured the haemodynamics during VF with Impella P4 support (n = 1 each). In Protocol 2 (n = 6), we compared the central and peripheral blood flows between the baseline conditions and three Impella support levels (P0, P4, and P8) during VF. In Protocol 2, an increase of Impella support to P4 and P8 during VF significantly increased AP in a support level-dependent manner (P0, P4, and P8: 26.5 ± 2.5, 57.7 ± 8.7 and 72.0 ± 15.3 mmHg, respectively; P < 0.001) while lowering RAP and LAP. Impella partially maintained PAF (0, 1.2 ± 0.6 and 1.6 ± 0.9 L/min; P = 0.011), CAF (0, 177.6 ± 26.3 and 235.5 ± 44.1 mL/min; P < 0.001), and CoF (0, 68.5 ± 32.0 and 57.8 ± 20.6 mL/min; P = 0.002) during VF. Conclusion: Impella preserved systemic, cerebral, and coronary blood flow with adequate SBV and normal PVR conditions in a goat model of VF.
- 20 August 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium
In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.
- 20 August 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium
In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.
- 1 August 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (2) , 496-508
A rapid increase in left atrial pressure reduces pulmonary arterial compliance in rats: insights from pulmonary arterial impedance analysis
Pulmonary arterial impedance estimation is minimally affected by left atrial pressure under physiological conditions; however, it is substantially affected by excessive increase in left atrial pressure. Rapid increase in atrial pressure is associated with significant decrease in pulmonary arterial compliance, with no changes in peripheral pulmonary resistance and characteristic impedance of proximal pulmonary arteries. Consequently, left atrial pressure should be taken into account when estimating pulmonary arterial impedance under conditions of elevated left atrial pressure.
- 1 August 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (2) , 496-508
A rapid increase in left atrial pressure reduces pulmonary arterial compliance in rats: insights from pulmonary arterial impedance analysis
Pulmonary arterial impedance estimation is minimally affected by left atrial pressure under physiological conditions; however, it is substantially affected by excessive increase in left atrial pressure. Rapid increase in atrial pressure is associated with significant decrease in pulmonary arterial compliance, with no changes in peripheral pulmonary resistance and characteristic impedance of proximal pulmonary arteries. Consequently, left atrial pressure should be taken into account when estimating pulmonary arterial impedance under conditions of elevated left atrial pressure.
- 10 July 2025
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Impact of dopamine on baroreflex-mediated sympathetic arterial pressure regulation in rats: An open-loop analysis
Dopamine is commonly used to treat hemodynamic collapse, but its effect on baroreflex-mediated sympathetic arterial pressure (AP) regulation remains to be elucidated. We quantified the effects of dopamine on AP regulation using a baroreflex open-loop analysis by measuring sympathetic nerve activity (SNA) and AP in response to stepwise changes in carotid sinus pressure (CSP) before and during intravenous infusion of dopamine at 2, 10, and 20 μg·kg−1·min−1 in anesthetized rats (n = 8). We analyzed the CSP–SNA relationship (neural arc) and the SNA–AP relationship (peripheral arc), and constructed a baroreflex equilibrium diagram. The gain at the operating point was calculated from the product of the tangential slope of the neural arc and the slope of the peripheral arc. Compared to baseline, dopamine at 20 μg·kg⁻¹·min⁻¹ significantly reduced the maximum gain of the neural arc [from 1.898 ± 0.150 to 1.277 ± 0.205 %/mmHg ( P = 0.014)]. Compared to baseline, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ significantly reduced the slope of the peripheral arc [from 0.806 ± 0.079 to 0.645 ± 0.091 mmHg/% ( P = 0.031) and 0.633 ± 0.100 mmHg/% ( P = 0.020), respectively] and the operating point gain [from 0.800 ± 0.187 to 0.462 ± 0.153 mmHg/mmHg ( P = 0.008) and 0.345 ± 0.122 mmHg/mmHg ( P < 0.001)], while maintaining the operating point AP. In conclusion, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ maintained the operating point AP but significantly reduced the operating point gain for AP regulation, potentially increasing AP variability and instability.
- 10 July 2025
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Impact of dopamine on baroreflex-mediated sympathetic arterial pressure regulation in rats: An open-loop analysis
Dopamine is commonly used to treat hemodynamic collapse, but its effect on baroreflex-mediated sympathetic arterial pressure (AP) regulation remains to be elucidated. We quantified the effects of dopamine on AP regulation using a baroreflex open-loop analysis by measuring sympathetic nerve activity (SNA) and AP in response to stepwise changes in carotid sinus pressure (CSP) before and during intravenous infusion of dopamine at 2, 10, and 20 μg·kg−1·min−1 in anesthetized rats (n = 8). We analyzed the CSP–SNA relationship (neural arc) and the SNA–AP relationship (peripheral arc), and constructed a baroreflex equilibrium diagram. The gain at the operating point was calculated from the product of the tangential slope of the neural arc and the slope of the peripheral arc. Compared to baseline, dopamine at 20 μg·kg⁻¹·min⁻¹ significantly reduced the maximum gain of the neural arc [from 1.898 ± 0.150 to 1.277 ± 0.205 %/mmHg ( P = 0.014)]. Compared to baseline, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ significantly reduced the slope of the peripheral arc [from 0.806 ± 0.079 to 0.645 ± 0.091 mmHg/% ( P = 0.031) and 0.633 ± 0.100 mmHg/% ( P = 0.020), respectively] and the operating point gain [from 0.800 ± 0.187 to 0.462 ± 0.153 mmHg/mmHg ( P = 0.008) and 0.345 ± 0.122 mmHg/mmHg ( P < 0.001)], while maintaining the operating point AP. In conclusion, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ maintained the operating point AP but significantly reduced the operating point gain for AP regulation, potentially increasing AP variability and instability.
- Open Access
- 23 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (6) , ytaf261
Evaluation with a haemodynamic simulator undergoing mitral transcatheter edge-to-edge repair in a giant left atrium
- 23 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (6) , ytaf261
Open AccessEvaluation with a haemodynamic simulator undergoing mitral transcatheter edge-to-edge repair in a giant left atrium