The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners
Authors:
- 23 May 2007
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 45 (6) , 553-562
Abstract
CT beam hardening artifacts near metal hip implants may erroneously enhance or diminish radiotracer uptake following CT attenuation correction (AC) of PET images. An artifact reduction algorithm (ARA) was developed to reduce metal artifacts in CT-based AC-PET. The algorithm employed a Bayes classifier to identify beam-hardening artifacts, followed by a partial correction of the attenuation map. ARA was implemented on phantom and patient 18F-FDG studies using a clinical PET/CT scanner. In phantom studies ARA successfully removed two artifacts of erroneously elevated uptake near a stainless steel hip prosthesis which were depicted in the standard CT-AC PET. ARA has also identified two targets absent on the scanner PET images. Target-to-background ratios were 1.5–3 times higher for ARA-PET than scanner images. In a patient study, metal artifacts were of lower intensity in ARA-PET as compared to standard images. Potentially, ARA may improve detectability of small lesions located near metal hip implants.Keywords
This publication has 28 references indexed in Scilit:
- Truncation Artifact on PET/CT: Impact on Measurements of Activity Concentration and Assessment of a Correction AlgorithmAmerican Journal of Roentgenology, 2006
- An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studiesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Is quantitation necessary for oncological PET studies?European Journal of Nuclear Medicine and Molecular Imaging, 2001
- X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prosthesesIEEE Transactions on Medical Imaging, 2000
- Attenuation correction for a combined 3D PET/CT scannerMedical Physics, 1998
- Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring ReconstructionJournal of Computer Assisted Tomography, 1997
- Positron-emission tomographyIEEE Signal Processing Magazine, 1997
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994