RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5T
Authors:
- Matt WaksMWMatt Waks
- Russell L. LagoreRLRussell L. Lagore
- Edward AuerbachEAEdward Auerbach
- Andrea GrantAGAndrea Grant
- Alireza Sadeghi‐TarakamehASAlireza Sadeghi‐Tarakameh
- Lance DelaBarreLDLance DelaBarre
- Steve JungstSJSteve Jungst
- Nader TavafNTNader Tavaf
- Riccardo LattanziRLRiccardo Lattanzi
- Ilias GiannakopoulosIGIlias Giannakopoulos
- Steen MoellerSMSteen Moeller
- Xiaoping WuXWXiaoping Wu
Open Access
- 16 October 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 873-888
Abstract
Purpose: Toward pushing the boundaries of ultrahigh fields for human brain imaging, we wish to evaluate experimentally achievable SNR relative to ultimate intrinsic SNR (uiSNR) at 10.5T, develop design strategies toward approaching the latter, quantify magnetic field–dependent SNR gains, and demonstrate the feasibility of whole‐brain, high‐resolution human brain imaging at this uniquely high field strength.Methods: A dual row 16‐channel self‐decoupled transmit (Tx) and receive (Rx) array was developed for 10.5T using custom Tx/Rx switches. A 64‐channel receive‐only array was built to fit into the 16‐channel Tx/Rx array. Electromagnetic modeling and experiments were used to define safe operational power limits. Experimental SNR was evaluated relative to uiSNR at 10.5T and 7T.Results: The 64‐channel Rx array alone captured approximately 50% of the central uiSNR at 10.5T, while an identical array developed for 7T captured about 76% of uiSNR at 7T. The 16‐channel Tx/80‐channel Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the 64‐channel Rx array at 7T. SNR data displayed an approximate dependence over a large central region when evaluated in the context of uiSNR. Whole‐brain, high‐resolution ‐weighted and T1‐weighted anatomical and gradient‐recalled‐echo BOLD‐EPI functional MRI images were obtained at 10.5T for the first time with such an advanced array.Conclusion: We demonstrated the ability to approach the uiSNR at 10.5T over the human brain, achieving large SNR gains over 7T, currently the most commonly used ultrahigh‐field platform. Whole‐brain, high‐resolution anatomical and EPI‐based functional MRI data were obtained at 10.5T, illustrating the promise of greater than 10T fields in studying the human brain.Keywords
Funding Information
- National Institutes of Health (S10 RR029672)
- National Institute of Neurological Disorders and Stroke (P30 NS076408, UM1 NS132207)
- National Institute of Biomedical Imaging and Bioengineering (P41 EB027061, R01 EB024536, U01 EB025144)
This publication has 75 references indexed in Scilit:
- 7T: Physics, safety, and potential clinical applicationsJournal of Magnetic Resonance Imaging, 2017
- Approaching ultimate intrinsic SNR in a uniform spherical sample with finite arrays of loop coilsConcepts in Magnetic Resonance Part B, 2014
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Concentric coil arrays for parallel MRIMagnetic Resonance in Medicine, 2005
- Electrodynamics and ultimate SNR in parallel MR imagingMagnetic Resonance in Medicine, 2004
- Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerationsMagnetic Resonance in Medicine, 2003
- Ultimate intrinsic signal‐to‐noise ratio in MRIMagnetic Resonance in Medicine, 1998
- The NMR phased arrayMagnetic Resonance in Medicine, 1990