Tension‐Dependent Variability and Repeatability of Achilles Tendon UTE‐T 2 * Mapping Using Mono‐ and Bi‐Exponential Models
- 9 May 2026
- journal article
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (6) , e70302
Abstract
Quantitative MRI using ultrashort echo time (UTE)‐T 2 * mapping is sensitive to collagen‐bound water and tendon microstructure, enabling noninvasive assessment of tendon integrity and laxity. However, the extent to which UTE‐T 2 * measures reflect changes in tendon tension, and their repeatability, remain incompletely understood. We evaluated the sensitivity of mono‐ and bi‐exponential UTE‐T 2 * measures of the Achilles tendon to changes in tendon tension induced by ankle positioning and assessed the test–retest repeatability of these metrics across repeated scan sessions. In this study, healthy adult volunteers underwent UTE‐MRI of the Achilles tendon at two scan sessions, spaced 1 week apart, with the ankle positioned in dorsiflexion (higher tendon tension) and plantarflexion (lower tendon tension). Mono‐exponential T 2 * (T 2 * mono ) and bi‐exponential parameters (T 2 * short , T 2 * long , and short‐component fraction ρ short ) were quantified. We performed a two‐way repeated‐measures ANOVA to assess the main effects of ankle position and scan session, and their interaction. Repeatability was evaluated using root mean square error (RMSE), coefficient of variation (CV%), and Bland–Altman analysis. We observed that short‐component T 2 * metrics demonstrated significant sensitivity to tendon tension. A main effect of ankle position was observed for T 2 * mono ( p < 0.001) and T 2 * short ( p = 0.02), with lower values in dorsiflexion compared with plantarflexion. No significant effect of scan session or ankle position × scan session interactions were observed. T 2 * long and ρ short showed no significant dependence on position or scan session, suggesting that bulk hydration and relative water‐compartment contributions remained stable across loading conditions. Dorsiflexion demonstrated lower RMSE and CV% across metrics than plantar flexion, indicating improved repeatability under passive tendon tension. UTE‐T 2 * relaxometry of the Achilles tendon is repeatable and sensitive to changes in tendon tension. Short T 2 * measures may provide quantitative imaging markers related to tendon mechanical integrity and laxity, while highlighting the importance of standardized tendon tension for longitudinal quantitative tendon MRI.Keywords
Funding Information
- GE Healthcare
This publication has 29 references indexed in Scilit:
- Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal ImagingJournal of Magnetic Resonance Imaging, 2021
- Tissue‐Specific T2* Biomarkers in Patellar Tendinopathy by Subregional Quantification Using 3D Ultrashort Echo Time MRIJournal of Magnetic Resonance Imaging, 2020
- Ultrashort echo time T2 ∗ values decrease in tendons with application of static tensile loadsJournal of Biomechanics, 2017
- T2* relaxation time in Achilles tendinosis and controls and its correlation with clinical scoreJournal of Magnetic Resonance Imaging, 2015
- Regional variations of T2* in healthy and pathologic achilles tendon in vivo at 7 Tesla: Preliminary resultsMagnetic Resonance in Medicine, 2012
- Ultrashort echo time imaging with bicomponent analysisMagnetic Resonance in Medicine, 2011
- Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequencesClinical Radiology, 2004
- Uniaxial tension inhibits tendon collagen degradation by collagenase in vitroJournal of Orthopaedic Research, 1996
- Anisotropy of NMR properties of tissuesMagnetic Resonance in Medicine, 1994
- Effect of cyclic and static tensile loading on water content and solute diffusion in canine flexor tendons: An in Vitro studyJournal of Orthopaedic Research, 1994