Achieving primary stability in low-density bone is a major challenge in implant dentistry, with high insertion torque (HIT) causing bone micro damage. Therefore, it is of interest to evaluate osteointegration of implants placed with low insertion torque (LIT, 15–25 Ncm) versus HIT (35–45 Ncm) in sheep femoral condyles. At 12 weeks, bone-to-implant contact (58.3% vs. 62.1%, p=0.18) and bone volume fraction (35.4% vs. 38.2%, p=0.22) were comparable between groups. Initial implant stability was lower with LIT but equalized with HIT at 12 weeks. Thus, LIT implants achieved similar osteointegration to HIT, supporting their use to reduce surgical trauma in soft bone.Keywords
This publication has 18 references indexed in Scilit:
- Early Loading of Nonsubmerged Titanium Implants with a Chemically Modified Sand‐Blasted and Acid‐Etched Surface: 6‐Month Results of a Prospective Case Series Study in the Posterior Mandible Focusing on Peri‐Implant Crestal Bone Changes and Implant Stability Quotient (ISQ) ValuesClinical Implant Dentistry and Related Research, 2009
- Performance of dental implants after staged sinus floor elevation procedures: 5‐year results of a prospective study in partially edentulous patientsClinical Oral Implants Research, 2008
- Primary stability of turned and acid-etched screw-type implants: a removal torque and histomorphometric study in rabbits.2008
- Early functional loading of sand‐blasted and acid‐etched (SLA) Straumann implants following immediate placement in maxillary extraction sockets. Clinical and radiographic resultClinical Oral Implants Research, 2007
- Clinical performance of wide-body implants with a sandblasted and acid-etched (SLA) surface: results of a 3-year follow-up study in a referral clinic.2007
- Immediate loading of implants with 3-unit fixed partial dentures: a 12-month clinical study.2006
- Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants.2006
- Clinical outcome of 802 immediately loaded 2-stage submerged implants with a new grit-blasted and acid-etched surface: 12-month follow-up.2006
- Correlation between placement torque and survival of single-tooth implants.2005