Multi‐echo MR thermometry using iterative separation of baseline water and fat images
- 5 November 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2385-2398
Abstract
Purpose: To perform multi‐echo water/fat separated proton resonance frequency (PRF)‐shift temperature mapping. Methods: State‐of‐the‐art, iterative multi‐echo water/fat separation algorithms produce high‐quality water and fat images in the absence of heating but are not suitable for real‐time imaging due to their long compute times and potential errors in heated regions. Existing fat‐referenced PRF‐shift temperature reconstruction methods partially address these limitations but do not address motion or large time‐varying and spatially inhomogeneous B0 shifts. We describe a model‐based temperature reconstruction method that overcomes these limitations by fitting a library of separated water and fat images measured before heating directly to multi‐echo data measured during heating, while accounting for the PRF shift with temperature. Results: Simulations in a mixed water/fat phantom with focal heating showed that the proposed algorithm reconstructed more accurate temperature maps in mixed tissues compared to a fat‐referenced thermometry method. In a porcine phantom experiment with focused ultrasound heating at 1.5 Tesla, temperature maps were accurate to within 1∘C of fiber optic probe temperature measurements and were calculated in 0.47 s per time point. Free‐breathing breast and liver imaging experiments demonstrated motion and off‐resonance compensation. The algorithm can also accurately reconstruct water/fat separated temperature maps from a single echo during heating. Conclusions: The proposed model‐based water/fat separated algorithm produces accurate PRF‐shift temperature maps in mixed water and fat tissues in the presence of spatiotemporally varying off‐resonance and motion.Keywords
Funding Information
- U.S. Department of War (W81XWH-13-1-0230)
- National Institutes of Health (T32EB021937)
This publication has 28 references indexed in Scilit:
- Correcting heat‐induced chemical shift distortions in proton resonance frequency‐shift thermometryMagnetic Resonance in Medicine, 2015
- Respiration artifact correction in three‐dimensional proton resonance frequency MR thermometry using phase navigatorsMagnetic Resonance in Medicine, 2015
- Addressing phase errors in fat‐water imaging using a mixed magnitude/complex fitting methodMagnetic Resonance in Medicine, 2011
- Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organsMedical Physics, 2010
- Chemical shift–based water/fat separation: A comparison of signal modelsMagnetic Resonance in Medicine, 2010
- Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organsMagnetic Resonance in Medicine, 2010
- Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithmMagnetic Resonance in Medicine, 2009
- Interleaved echo‐planar imaging for fast multiplanar magnetic resonance temperature imaging of ultrasound thermal ablation therapyJournal of Magnetic Resonance Imaging, 2004
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003
- Triggered, navigated, multi‐baseline method for proton resonance frequency temperature mapping with respiratory motionMagnetic Resonance in Medicine, 2003