Image quality and pulmonary nodule detectability at low-dose computed tomography (low kVp and mAs): A phantom study
Open Access
- 1 January 2022
- journal article
- research article
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 12 (1) , 64-68
Abstract
Background: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most of them are time-consuming, intricate, and vendor-based strategies that are hardly used in clinics routinely. This study aims to evaluate the image quality and pulmonary nodule detectability of LDCT protocols that are feasible and easy implemented. Image quality was analyzed in a general quality control phantom (Gammex) and then in a manmade lung phantom with nodules-equivalent objects. Methods: This study was designed in a two steps, in the first step, a feasible low-dose lung CT protocol was selected with quality assessment of accreditation phantom image. In the second step, the selected low-dose protocol with an appropriate image quality was performed on a manmade lung phantom in which there were objects equivalent to the pulmonary nodule. Finally, image quality parameters of the phantom at the appropriate scan protocol were compared with the standard protocol. Results: A reduction of about 17% of kVp and 46% in tube current leads to dose reduction by about 70%. The contrast-to-noise ratio in the low-dose protocol remained almost unchanged. The signal-to-noise ratio in the low-dose protocol decreased by approximately 32%, and the noise level has increased by about 1.5 times. However, this reduction method hardly affected the detectability of nodules in man-made pulmonary phantom. Conclusions: Here, we demonstrated that the LDCT scan has an insignificant effect on the perception of lung nodules. In this study, patient dose in lung CT was reduced by modifying of kVp and mAs about approximately 70%. Hence, to step in toward low-dose strategies in medical imaging clinics, using easy-implemented and feasible low-dose strategies may be helpful.Keywords
This publication has 23 references indexed in Scilit:
- Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image qualityDiagnostic and Interventional Imaging, 2016
- Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom studyEuropean Radiology, 2016
- Low dose chest CT protocol (50 mAs) as a routine protocol for comprehensive assessment of intrathoracic abnormalityEuropean Journal of Radiology Open, 2016
- Image quality in CT: From physical measurements to model observersPhysica Medica, 2015
- Overdiagnosis in Low-Dose Computed Tomography Screening for Lung CancerJAMA Internal Medicine, 2014
- CT Scan Parameters and Radiation Dose: Practical Advice for RadiologistsJournal of the American College of Radiology, 2013
- Radiation Risk From CT: Implications for Cancer ScreeningAmerican Journal of Roentgenology, 2013
- Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CTBritish Journal of Radiology, 2012
- Benefits and Harms of CT Screening for Lung CancerJAMA, 2012
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic ScreeningThe New England journal of medicine, 2011