The frost resistance of concrete is a function of the concrete constituent properties, entrained air-void system parameters and environmental exposure history. However, only a single maximum value for the void spacing factor is specified for all types of concrete by code writing bodies for successful protection against freezing damage. The advent and utilisation of new materials over the recent years warrant reevaluation of the validity of this single pass/fail criteria established more than 50 years ago. Here, a poromechanical model, capable of incorporating concrete constituent properties, environmental exposure and air-void spacing factor, has been used to determine the role of various concrete constituents and air-void system on the damage propensity of concrete exposed to freezing temperatures. It is found that a maximum threshold of acceptance, for instance a 0.2 mm spacing factor, may not be adequate for all concrete mixture designs subject to various cooling conditions. The model also suggests that concrete with low-porosity, low-permeability mortar matrix, a characteristic property of mortar containing supplementary cementitious materials and/or low water to cement ratio, can perform satisfactorily under freezing temperatures even with a spacing factor greater than the recommended value. If utilised for design, this model will give more freedom to practitioners in ensuring concrete durability by controlling multiple factors including the concrete mixture components and proportions rather than just satisfying a single pass/fail criterion for void spacing factor for all concrete mixtures.Keywords
Funding Information
- Southwest Region University Transportation Center
This publication has 17 references indexed in Scilit:
- Quantitative damage evaluation of concrete suffered freezing–thawing by DIP techniqueConstruction and Building Materials, 2014
- Effect of air-void system on frost expansion of highway concrete exposed to deicer saltInternational Journal of Pavement Engineering, 2012
- Coupled thermo-hydraulic modelling of pavement under frostInternational Journal of Pavement Engineering, 2012
- Examining the frost resistance of high performance concreteConstruction and Building Materials, 2009
- Poroelastic model for concrete exposed to freezing temperaturesCement and Concrete Research, 2008
- Unsaturated poroelasticity for crystallization in poresComputers and Geotechnics, 2007
- Thermal dilation and internal relative humidity of hardened cement pasteMaterials and Structures, 2006
- X-ray microtomographic studies of pore structure and permeability in Portland cement concreteMaterials and Structures, 2006
- Poromechanics of freezing materialsJournal of the Mechanics and Physics of Solids, 2005
- The relationship between an aggregate's pore size distribution and its freeze thaw durability in concreteCement and Concrete Research, 1980