10 kHz Shifted-Excitation Raman Difference Spectroscopy with Charge-Shifting Charge-Coupled Device Read-Out for Effective Mitigation of Dynamic Interfering Backgrounds
Open Access
- 25 April 2023
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 77 (6) , 569-582
Abstract
In this work we demonstrate an advanced concept of a charge-shifting charge-coupled device (CCD) read-out combined with shifted excitation Raman difference spectroscopy (SERDS) capable of operating at up to 10 kHz acquisition rates for the effective mitigation of fast-evolving interfering backgrounds in Raman spectroscopy. This rate is 10-fold faster than that achievable with an instrument we described previously and is overall 1000-fold faster than possible with conventional spectroscopic CCDs capable of operating at up to ∼10 Hz rates. The speed enhancement was realized by incorporating a periodic mask at the internal slit of an imaging spectrometer permitting a smaller shift of the charge on the CCD (8 pixels) to be required during the cyclic shifting process compared with the earlier design which employed an 80-pixel shift. The higher acquisition speed enables the more accurate sampling of the two SERDS spectral channels, enabling it to effectively tackle highly challenging situations with rapidly evolving interfering fluorescence backgrounds. The performance of the instrument is evaluated for heterogeneous fluorescent samples which are moved rapidly in front of the detection system aiming at the differentiation of chemical species and their quantification. The performance of the system is compared with that of the earlier 1 kHz design and a conventional CCD operated at its maximum rate of 5.4 Hz as previously. In all situations tested, the newly developed 10 kHz system outperformed the earlier variants. The 10 kHz instrument can benefit a number of prospective applications including: disease diagnosis where high sensitivity mapping of complex biological matrices in the presence of natural fluorescence bleaching restricts achievable limits of detection; accurate data acquisition from moving heterogeneous samples (or moving a handheld instrument in front of the sample during data acquisition) or data acquisition under varying ambient light conditions (e.g., due to casting shadows, sample or instrument movement). Other beneficial scenarios include monitoring rapidly evolving Raman signals in the presence of largely static background signals such as in situations where a heterogeneous sample is moving rapidly in front of a detection system (e.g., a conveyor belt) in the presence of static ambient light.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/R020965/1)
This publication has 23 references indexed in Scilit:
- Tailored diode lasers: enabling Raman spectroscopy in the presence of disturbing fluorescence and background light2019
- Fast Raman spectral mapping of highly fluorescing samples by time-gated spectral multiplexed detectionOptics Letters, 2018
- A shifted‐excitation Raman difference spectroscopy (SERDS) evaluation strategy for the efficient isolation of Raman spectra from extreme fluorescence interferenceJournal of Raman Spectroscopy, 2015
- Review of Fluorescence Suppression Techniques in Raman SpectroscopyApplied Spectroscopy Reviews, 2015
- Simple Reconstruction Algorithm for Shifted Excitation Raman Difference SpectroscopyApplied Spectroscopy, 2005
- Image Curvature Correction and Cosmic Removal for High-Throughput Dispersive Raman SpectroscopyApplied Spectroscopy, 2003
- Automated Fluorescence Rejection Using Shifted Excitation Raman Difference SpectroscopyApplied Spectroscopy, 2002
- Fluorescence background suppression in Raman spectroscopy using combined Kerr gated and shifted excitation Raman difference techniquesJournal of Raman Spectroscopy, 2002
- Efficient Rejection of Fluorescence from Raman Spectra Using Picosecond Kerr GatingApplied Spectroscopy, 1999
- Effective Rejection of Fluorescence Interference in Raman Spectroscopy Using a Shifted Excitation Difference TechniqueApplied Spectroscopy, 1992