William Hamish Skinner
Research Subjects
William Hamish Skinner has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Nicholas Stone
Department of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, UK
5 shared publications - Pavel Matousek
STFC Rutherford Appleton Laboratory UKRI
5 shared publications - Sara Mosca
Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRI, Harwell Campus, OX11 0QX, UK
5 shared publications - Francesca Palombo
Department of Physics and Astronomy, University of Exeter, Exeter, UK
4 shared publications - Benjamin Gardner
Physics and Astronomy, Faculty of Environment, Science and Economy, University of Exeter, Exeter, Devon, UK
3 shared publications - Colin J. Campbell
EaStCHEM School of Chemistry, The University of Edinburgh, King’s Buildings, Mayfield Road, Edinburgh EH9 3FJ, U.K.
3 shared publications
Latest Publications
- Open Access
pH-Dependent Silica Nanoshell Degradation Influences SERRS Enhancement in Biological Environments
Silica-encapsulated gold nanostars (AuNStar-SiO 2 ) are a widely used plasmonic nanoparticle platform for surface-enhanced resonance Raman scattering (SERRS) bio-applications. In this paper, we demonstrate that coupled nanostar subpopulations can dominate the ensemble-average SERRS response of the suspension and that near-neutral standard cell culture conditions are sufficient to hydrolyze the silica nanoshell and introduce variability in signal intensity following in vitro endocytosis. Monomeric and oligomeric AuNStar-SiO 2 fractions were isolated using continuous density-gradient centrifugation and monomeric populations were found to exhibit significantly weaker SERRS compared to their oligomeric counterparts. Using monomer-enriched AuNStar-SiO 2 , we investigated the stability of the silica nanoshell under conditions representative of sequential acidification during endocytosis and characterized the subsequent changes to nanoparticle optical properties. In acidic environments, reflecting lysosomal pH, the silica shell was stable, whereas near-neutral and alkaline conditions in cell culture medium induced silica-shell hydrolysis, nanostar release, and interparticle aggregation, leading to transient SERS amplification. When cells were treated with AuNStar-SiO 2 under near-neutral and acidic conditions, we observed the opposite trend in SERS signal strength. At pH 7.4, the SERRS signal was suppressed even though transmission electron microscopy (TEM) images of intracellular nanoparticles showed progressive extents of silica hydrolysis, while at pH 6.4 SERS signal was strong and the silica shell of intracellular nanoparticles remained intact. Together, these findings show how SERRS output can differ between control conditions and biological applications, highlighting the role that local environmental factors play in nanoparticle stability and performance. Our results highlight the previously overlooked role of silica nanoshell instability on SERRS signal output in physiological environments and describe opportunities to harness silica nanoshell hydrolysis to improve the biomedical application of silica-coated plasmonic probes.
Open AccesspH-Dependent Silica Nanoshell Degradation Influences SERRS Enhancement in Biological Environments
Silica-encapsulated gold nanostars (AuNStar-SiO 2 ) are a widely used plasmonic nanoparticle platform for surface-enhanced resonance Raman scattering (SERRS) bio-applications. In this paper, we demonstrate that coupled nanostar subpopulations can dominate the ensemble-average SERRS response of the suspension and that near-neutral standard cell culture conditions are sufficient to hydrolyze the silica nanoshell and introduce variability in signal intensity following in vitro endocytosis. Monomeric and oligomeric AuNStar-SiO 2 fractions were isolated using continuous density-gradient centrifugation and monomeric populations were found to exhibit significantly weaker SERRS compared to their oligomeric counterparts. Using monomer-enriched AuNStar-SiO 2 , we investigated the stability of the silica nanoshell under conditions representative of sequential acidification during endocytosis and characterized the subsequent changes to nanoparticle optical properties. In acidic environments, reflecting lysosomal pH, the silica shell was stable, whereas near-neutral and alkaline conditions in cell culture medium induced silica-shell hydrolysis, nanostar release, and interparticle aggregation, leading to transient SERS amplification. When cells were treated with AuNStar-SiO 2 under near-neutral and acidic conditions, we observed the opposite trend in SERS signal strength. At pH 7.4, the SERRS signal was suppressed even though transmission electron microscopy (TEM) images of intracellular nanoparticles showed progressive extents of silica hydrolysis, while at pH 6.4 SERS signal was strong and the silica shell of intracellular nanoparticles remained intact. Together, these findings show how SERRS output can differ between control conditions and biological applications, highlighting the role that local environmental factors play in nanoparticle stability and performance. Our results highlight the previously overlooked role of silica nanoshell instability on SERRS signal output in physiological environments and describe opportunities to harness silica nanoshell hydrolysis to improve the biomedical application of silica-coated plasmonic probes.
- Open Access
- 4 April 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (14) , 13779-13789
An All-in-One Nanoheater and Optical Thermometer Fabricated from Fractal Nanoparticle Assemblies
We designed and optimized a dual-functional photothermal agent that performs as a nanoheater and real-time optical thermometer by leveraging gold nanoparticle (AuNP) self-assembly and anti-Stokes thermometry. We engineered colloidally stable fractal AuNP clusters with well-defined nanogaps to absorb strongly in the near-infrared and enhance anti-Stokes vibrational modes via surface-enhanced Raman scattering (SERS) for electromagnetic (EM) hotspot-localized thermometry during plasmonic heating. Photothermal characterization and simulations of a range of AuNP building block sizes demonstrated that 40 nm AuNPs are optimum for combined plasmonic heating and SERS due to the high probability of in resonance chains within assemblies. We explored the relationship between the far-field of our AuNP clusters and the near-field enhancement of anti-Stokes modes in the context of SERS thermometry, setting out design considerations for applying SERS thermometry. Finally, using a single near-infrared (NIR) laser source, we demonstrated plasmonic heating of a colloidal system with simultaneous accurate temperature measurement from EM hotspots via the thermal information encoded in the anti-Stokes mode of surface-bound Raman reporter molecules. Ultimately, our approach could enable real-time noninvasive temperature feedback from plasmonic nanoparticles within tumor tissue environments to guide safe and effective temperature increases during cancer photothermal therapy.
- 4 April 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (14) , 13779-13789
Open AccessAn All-in-One Nanoheater and Optical Thermometer Fabricated from Fractal Nanoparticle Assemblies
We designed and optimized a dual-functional photothermal agent that performs as a nanoheater and real-time optical thermometer by leveraging gold nanoparticle (AuNP) self-assembly and anti-Stokes thermometry. We engineered colloidally stable fractal AuNP clusters with well-defined nanogaps to absorb strongly in the near-infrared and enhance anti-Stokes vibrational modes via surface-enhanced Raman scattering (SERS) for electromagnetic (EM) hotspot-localized thermometry during plasmonic heating. Photothermal characterization and simulations of a range of AuNP building block sizes demonstrated that 40 nm AuNPs are optimum for combined plasmonic heating and SERS due to the high probability of in resonance chains within assemblies. We explored the relationship between the far-field of our AuNP clusters and the near-field enhancement of anti-Stokes modes in the context of SERS thermometry, setting out design considerations for applying SERS thermometry. Finally, using a single near-infrared (NIR) laser source, we demonstrated plasmonic heating of a colloidal system with simultaneous accurate temperature measurement from EM hotspots via the thermal information encoded in the anti-Stokes mode of surface-bound Raman reporter molecules. Ultimately, our approach could enable real-time noninvasive temperature feedback from plasmonic nanoparticles within tumor tissue environments to guide safe and effective temperature increases during cancer photothermal therapy.
- Open Access
- 28 January 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (5) , 4588-4598
Gold Nanoraspberries for Surface-Enhanced Raman Scattering: Synthesis, Optimization, and Characterization
In this work, we demonstrate the synthesis of gold nanoraspberries (AuNRB) using a HEPES buffer at room temperature. The study aimed to identify and compare the physicochemical conditions of the AuNRB and gold nanospheres (AuNS) of similar size to a selected set of reporter molecules. The dispersion stability of shape-controlled and AuNS of similar diameters was investigated in three different physiological media, ultrapure water, phosphate-buffered saline (PBS), and fetal bovine serum (FBS), and compared to understand the effect of NP shape, dispersion stability, and surface-enhanced Raman scattering (SERS) enhancement. We have used two nonresonant reporters, trans-1,2-bis(4-pyridyl) ethylene (BPE) and biphenyl-4-thiol (BPT), and a resonant reporter, IR820 (also known as new indocyanine green), a clinically approved dye for diagnostic studies, to explore the relative benefit of using molecular electronic resonance, i.e., comparing SERS vs surface-enhanced resonance Raman scattering (SERRS) with these nanoparticles. SERS has been explored extensively for biomedical applications, but the synthesis of bright gold nanoparticles and the appropriate Raman label is still challenging. To understand and optimize the SERS process, we have characterized both types of gold nanoparticles, ranging from their average size, ζ-potential, and ultraviolet-visible (UV-vis) absorption. It has been found that AuNRB and AuNS are most stable when dispersed in ultrapure water, while significant aggregation of both types has been observed when dispersed in PBS. With 10% FBS, there was a slight shift and increase in the surface plasmon absorbance peak, which resulted from an increase in particle size due to protein corona formation around the gold nanoparticles. For SERS efficiency, it has been found that AuNRB outperform AuNS with all reporters. Further, the resonant reporter, IR820, has provided a higher SERS signal compared to BPE and BPT and with its FDA approval for clinical use is clearly a strong candidate for future in vivo application.
- 28 January 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (5) , 4588-4598
Open AccessGold Nanoraspberries for Surface-Enhanced Raman Scattering: Synthesis, Optimization, and Characterization
In this work, we demonstrate the synthesis of gold nanoraspberries (AuNRB) using a HEPES buffer at room temperature. The study aimed to identify and compare the physicochemical conditions of the AuNRB and gold nanospheres (AuNS) of similar size to a selected set of reporter molecules. The dispersion stability of shape-controlled and AuNS of similar diameters was investigated in three different physiological media, ultrapure water, phosphate-buffered saline (PBS), and fetal bovine serum (FBS), and compared to understand the effect of NP shape, dispersion stability, and surface-enhanced Raman scattering (SERS) enhancement. We have used two nonresonant reporters, trans-1,2-bis(4-pyridyl) ethylene (BPE) and biphenyl-4-thiol (BPT), and a resonant reporter, IR820 (also known as new indocyanine green), a clinically approved dye for diagnostic studies, to explore the relative benefit of using molecular electronic resonance, i.e., comparing SERS vs surface-enhanced resonance Raman scattering (SERRS) with these nanoparticles. SERS has been explored extensively for biomedical applications, but the synthesis of bright gold nanoparticles and the appropriate Raman label is still challenging. To understand and optimize the SERS process, we have characterized both types of gold nanoparticles, ranging from their average size, ζ-potential, and ultraviolet-visible (UV-vis) absorption. It has been found that AuNRB and AuNS are most stable when dispersed in ultrapure water, while significant aggregation of both types has been observed when dispersed in PBS. With 10% FBS, there was a slight shift and increase in the surface plasmon absorbance peak, which resulted from an increase in particle size due to protein corona formation around the gold nanoparticles. For SERS efficiency, it has been found that AuNRB outperform AuNS with all reporters. Further, the resonant reporter, IR820, has provided a higher SERS signal compared to BPE and BPT and with its FDA approval for clinical use is clearly a strong candidate for future in vivo application.
- Open Access
- 9 January 2025
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 129 (3) , 1864-1872
Plasmonic Nanoparticles for Photothermal Therapy: Benchmarking of Photothermal Properties and Modeling of Heating at Depth in Human Tissues
Many different types of nanoparticles have been developed for photothermal therapy (PTT), but directly comparing their efficacy as heaters and determining how they will perform when localized at depth in tissue remains complex. To choose the optimal nanoparticle for a desired hyperthermic therapy, it is vital to understand how efficiently different nanoparticles extinguish laser light and convert that energy to heat. In this paper, we apply photothermal mass conversion efficiency (η m ) as a metric to compare nanoparticles of different shapes, sizes, and conversion efficiencies. We selected silica-gold nanoshells (AuNShells), gold nanorods (AuNRs), and gold nanostars (AuNStars) as three archetypal nanoparticles for PTT and measured the η m of each to demonstrate the importance of considering both photothermal efficiency and extinction cross section when comparing nanoparticles. By utilizing a Monte Carlo model, we further applied η m to model how AuNRs performed when located at tissue depths of 0-30 mm by simulating the depth penetration of near-infrared (NIR) laser light. These results show how nanoparticle concentration, laser power, and tissue depth influence the ramp time to a hyperthermic temperature of 43 °C. The methodology outlined in this paper creates a framework to benchmark the heating efficacy of different nanoparticle types and a means of estimating the feasibility of nanoparticle-mediated PTT at depth in the NIR window. These are key considerations when predicting the potential clinical impact in the early stages of nanoparticle design.
- 9 January 2025
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 129 (3) , 1864-1872
Open AccessPlasmonic Nanoparticles for Photothermal Therapy: Benchmarking of Photothermal Properties and Modeling of Heating at Depth in Human Tissues
Many different types of nanoparticles have been developed for photothermal therapy (PTT), but directly comparing their efficacy as heaters and determining how they will perform when localized at depth in tissue remains complex. To choose the optimal nanoparticle for a desired hyperthermic therapy, it is vital to understand how efficiently different nanoparticles extinguish laser light and convert that energy to heat. In this paper, we apply photothermal mass conversion efficiency (η m ) as a metric to compare nanoparticles of different shapes, sizes, and conversion efficiencies. We selected silica-gold nanoshells (AuNShells), gold nanorods (AuNRs), and gold nanostars (AuNStars) as three archetypal nanoparticles for PTT and measured the η m of each to demonstrate the importance of considering both photothermal efficiency and extinction cross section when comparing nanoparticles. By utilizing a Monte Carlo model, we further applied η m to model how AuNRs performed when located at tissue depths of 0-30 mm by simulating the depth penetration of near-infrared (NIR) laser light. These results show how nanoparticle concentration, laser power, and tissue depth influence the ramp time to a hyperthermic temperature of 43 °C. The methodology outlined in this paper creates a framework to benchmark the heating efficacy of different nanoparticle types and a means of estimating the feasibility of nanoparticle-mediated PTT at depth in the NIR window. These are key considerations when predicting the potential clinical impact in the early stages of nanoparticle design.
- Open Access
- 7 August 2024
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 79 (2) , 320-327
Active Surface-Enhanced Raman Spectroscopy (SERS): A Novel Concept for Enhancing Signal Contrast in Complex Matrices Using External Perturbation
Noninvasive detection of surface-enhanced Raman spectroscopy (SERS) signals from deep within tissue represents a common challenge in many biological and clinical applications including disease diagnosis and therapy monitoring. Such signals are typically weak and not readily discernible from often much larger Raman and fluorescence background signals (e.g., from surrounding tissue). Consequently, suboptimal sensitivity in the detection of SERS signals is often achieved in these situations. Similar issues can arise in SERS measurements in other diffusely scattering samples and complex matrices. Here, we propose a novel concept, active SERS, for the efficient retrieval of SERS signals from deep within complex matrices such as biological tissues that mitigates these issues. It relies on applying an external perturbation to the sample to alter the SERS signal from nanoparticles (NPs) deep inside the matrix. A measurement with and without, or before and after, such perturbation then can provide powerful contrasting data enabling an effective elimination of the matrix signals to reveal more clearly the desired SERS signal without the interfering background and associated artifacts. The concept is demonstrated using ultrasound (US) as an external source of perturbation and SERS NPs inserted deep within a heterogeneous tissue phantom mimicking a cluster of NPs accumulated within a small target lesion. The overall SERS signal intensity induced by the applied US perturbation decreased by ∼21% and the SERS signal contrast was considerably improved by eliminating subtraction artifacts present in a conventional measurement performed at a neighboring spatial location in a heterogeneous tissue sample. Although the technique was demonstrated with SERS gold NPs with a standard Raman label, it is envisaged that active SERS NPs (both the nanoscale metal geometry and Raman label) could be specifically designed to deliver an augmented response to the external stimulus to further enhance the achievable SERS signal contrast and yield even greater improvement in detection sensitivity. The method was demonstrated using transmission Raman spectroscopy; however, it is also applicable to other Raman implementations including spatially offset Raman spectroscopy and conventional Raman spectroscopy performed both at depth and at surfaces of complex matrices.
- 7 August 2024
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 79 (2) , 320-327
Open AccessActive Surface-Enhanced Raman Spectroscopy (SERS): A Novel Concept for Enhancing Signal Contrast in Complex Matrices Using External Perturbation
Noninvasive detection of surface-enhanced Raman spectroscopy (SERS) signals from deep within tissue represents a common challenge in many biological and clinical applications including disease diagnosis and therapy monitoring. Such signals are typically weak and not readily discernible from often much larger Raman and fluorescence background signals (e.g., from surrounding tissue). Consequently, suboptimal sensitivity in the detection of SERS signals is often achieved in these situations. Similar issues can arise in SERS measurements in other diffusely scattering samples and complex matrices. Here, we propose a novel concept, active SERS, for the efficient retrieval of SERS signals from deep within complex matrices such as biological tissues that mitigates these issues. It relies on applying an external perturbation to the sample to alter the SERS signal from nanoparticles (NPs) deep inside the matrix. A measurement with and without, or before and after, such perturbation then can provide powerful contrasting data enabling an effective elimination of the matrix signals to reveal more clearly the desired SERS signal without the interfering background and associated artifacts. The concept is demonstrated using ultrasound (US) as an external source of perturbation and SERS NPs inserted deep within a heterogeneous tissue phantom mimicking a cluster of NPs accumulated within a small target lesion. The overall SERS signal intensity induced by the applied US perturbation decreased by ∼21% and the SERS signal contrast was considerably improved by eliminating subtraction artifacts present in a conventional measurement performed at a neighboring spatial location in a heterogeneous tissue sample. Although the technique was demonstrated with SERS gold NPs with a standard Raman label, it is envisaged that active SERS NPs (both the nanoscale metal geometry and Raman label) could be specifically designed to deliver an augmented response to the external stimulus to further enhance the achievable SERS signal contrast and yield even greater improvement in detection sensitivity. The method was demonstrated using transmission Raman spectroscopy; however, it is also applicable to other Raman implementations including spatially offset Raman spectroscopy and conventional Raman spectroscopy performed both at depth and at surfaces of complex matrices.
- Open Access
- 25 April 2023
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 77 (6) , 569-582
10 kHz Shifted-Excitation Raman Difference Spectroscopy with Charge-Shifting Charge-Coupled Device Read-Out for Effective Mitigation of Dynamic Interfering Backgrounds
In this work we demonstrate an advanced concept of a charge-shifting charge-coupled device (CCD) read-out combined with shifted excitation Raman difference spectroscopy (SERDS) capable of operating at up to 10 kHz acquisition rates for the effective mitigation of fast-evolving interfering backgrounds in Raman spectroscopy. This rate is 10-fold faster than that achievable with an instrument we described previously and is overall 1000-fold faster than possible with conventional spectroscopic CCDs capable of operating at up to ∼10 Hz rates. The speed enhancement was realized by incorporating a periodic mask at the internal slit of an imaging spectrometer permitting a smaller shift of the charge on the CCD (8 pixels) to be required during the cyclic shifting process compared with the earlier design which employed an 80-pixel shift. The higher acquisition speed enables the more accurate sampling of the two SERDS spectral channels, enabling it to effectively tackle highly challenging situations with rapidly evolving interfering fluorescence backgrounds. The performance of the instrument is evaluated for heterogeneous fluorescent samples which are moved rapidly in front of the detection system aiming at the differentiation of chemical species and their quantification. The performance of the system is compared with that of the earlier 1 kHz design and a conventional CCD operated at its maximum rate of 5.4 Hz as previously. In all situations tested, the newly developed 10 kHz system outperformed the earlier variants. The 10 kHz instrument can benefit a number of prospective applications including: disease diagnosis where high sensitivity mapping of complex biological matrices in the presence of natural fluorescence bleaching restricts achievable limits of detection; accurate data acquisition from moving heterogeneous samples (or moving a handheld instrument in front of the sample during data acquisition) or data acquisition under varying ambient light conditions (e.g., due to casting shadows, sample or instrument movement). Other beneficial scenarios include monitoring rapidly evolving Raman signals in the presence of largely static background signals such as in situations where a heterogeneous sample is moving rapidly in front of a detection system (e.g., a conveyor belt) in the presence of static ambient light.
- 25 April 2023
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 77 (6) , 569-582
Open Access10 kHz Shifted-Excitation Raman Difference Spectroscopy with Charge-Shifting Charge-Coupled Device Read-Out for Effective Mitigation of Dynamic Interfering Backgrounds
In this work we demonstrate an advanced concept of a charge-shifting charge-coupled device (CCD) read-out combined with shifted excitation Raman difference spectroscopy (SERDS) capable of operating at up to 10 kHz acquisition rates for the effective mitigation of fast-evolving interfering backgrounds in Raman spectroscopy. This rate is 10-fold faster than that achievable with an instrument we described previously and is overall 1000-fold faster than possible with conventional spectroscopic CCDs capable of operating at up to ∼10 Hz rates. The speed enhancement was realized by incorporating a periodic mask at the internal slit of an imaging spectrometer permitting a smaller shift of the charge on the CCD (8 pixels) to be required during the cyclic shifting process compared with the earlier design which employed an 80-pixel shift. The higher acquisition speed enables the more accurate sampling of the two SERDS spectral channels, enabling it to effectively tackle highly challenging situations with rapidly evolving interfering fluorescence backgrounds. The performance of the instrument is evaluated for heterogeneous fluorescent samples which are moved rapidly in front of the detection system aiming at the differentiation of chemical species and their quantification. The performance of the system is compared with that of the earlier 1 kHz design and a conventional CCD operated at its maximum rate of 5.4 Hz as previously. In all situations tested, the newly developed 10 kHz system outperformed the earlier variants. The 10 kHz instrument can benefit a number of prospective applications including: disease diagnosis where high sensitivity mapping of complex biological matrices in the presence of natural fluorescence bleaching restricts achievable limits of detection; accurate data acquisition from moving heterogeneous samples (or moving a handheld instrument in front of the sample during data acquisition) or data acquisition under varying ambient light conditions (e.g., due to casting shadows, sample or instrument movement). Other beneficial scenarios include monitoring rapidly evolving Raman signals in the presence of largely static background signals such as in situations where a heterogeneous sample is moving rapidly in front of a detection system (e.g., a conveyor belt) in the presence of static ambient light.
- Open Access
- 14 February 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (22) , 3249-3252
SERS microsensors for pH measurements in the lumen and ECM of stem cell derived human airway organoids
SERS microsensors (SERS-MS) are polymer microparticles coated in gold nanoparticles and functionalised with mercaptobenzoic acid. SERS-MS were incorporated into human airway organoids to measured pH optically.
- 14 February 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (22) , 3249-3252
Open AccessSERS microsensors for pH measurements in the lumen and ECM of stem cell derived human airway organoids
SERS microsensors (SERS-MS) are polymer microparticles coated in gold nanoparticles and functionalised with mercaptobenzoic acid. SERS-MS were incorporated into human airway organoids to measured pH optically.
- 21 October 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (43) , 51504-51518
Fabrication of a Wearable Flexible Sweat pH Sensor Based on SERS-Active Au/TPU Electrospun Nanofibers
Development of wearable sensing platforms is essential for the advancement of continuous health monitoring and point-of-care testing. Eccrine sweat pH is an analyte that can be noninvasively measured and used to diagnose and aid in monitoring a wide range of physiological conditions. Surface-enhanced Raman scattering (SERS) offers a rapid, optical technique for fingerprinting of biomarkers present in sweat. In this paper, a mechanically flexible, nanofibrous, SERS-active substrate was fabricated by a combination of electrospinning of thermoplastic polyurethane (TPU) and Au sputter coating. This substrate was then investigated for suitability toward wearable sweat pH sensing after functionalization with two commonly used pH-responsive molecules, 4-mercaptobenzoic acid (4-MBA), and 4-mercaptopyridine (4-MPy). The developed SERS pH sensor was found to have good resolution (0.14 pH units for 4-MBA; 0.51 pH units for 4-MPy), with only 1 μL of sweat required for a measurement, and displayed no statistically significant difference in performance after 35 days (p = 0.361). Additionally, the Au/TPU nanofibrous SERS pH sensors showed fast sweat-absorbing ability as well as good repeatability and reversibility. The proposed methodology offers a facile route for the fabrication of SERS substrates which could also be used to measure a wide range of health biomarkers beyond sweat pH.
- 21 October 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (43) , 51504-51518
Fabrication of a Wearable Flexible Sweat pH Sensor Based on SERS-Active Au/TPU Electrospun Nanofibers
Development of wearable sensing platforms is essential for the advancement of continuous health monitoring and point-of-care testing. Eccrine sweat pH is an analyte that can be noninvasively measured and used to diagnose and aid in monitoring a wide range of physiological conditions. Surface-enhanced Raman scattering (SERS) offers a rapid, optical technique for fingerprinting of biomarkers present in sweat. In this paper, a mechanically flexible, nanofibrous, SERS-active substrate was fabricated by a combination of electrospinning of thermoplastic polyurethane (TPU) and Au sputter coating. This substrate was then investigated for suitability toward wearable sweat pH sensing after functionalization with two commonly used pH-responsive molecules, 4-mercaptobenzoic acid (4-MBA), and 4-mercaptopyridine (4-MPy). The developed SERS pH sensor was found to have good resolution (0.14 pH units for 4-MBA; 0.51 pH units for 4-MPy), with only 1 μL of sweat required for a measurement, and displayed no statistically significant difference in performance after 35 days (p = 0.361). Additionally, the Au/TPU nanofibrous SERS pH sensors showed fast sweat-absorbing ability as well as good repeatability and reversibility. The proposed methodology offers a facile route for the fabrication of SERS substrates which could also be used to measure a wide range of health biomarkers beyond sweat pH.
- 5 October 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (41) , 13844-13851
A SERS-Active Electrospun Polymer Mesh for Spatially Localized pH Measurements of the Cellular Microenvironment
Extracellular pH (pHe) is an important chemical factor in many cellular processes and disease pathologies. The routine sampling of pHe in vitro could lead to innovative advances in therapeutics. To this end, we have fabricated a novel gold-coated polymer mesh, which facilitates the real-time measurement of pHe via surface-enhanced Raman scattering (SERS). In this proof of concept study, we apply our SERS sensor to measure metabolically induced changes in the pHe of carcinoma-derived cell line HepG2/C3A. We demonstrate that gold-coated polyurethane electrospun nanofibers (AuNF) have strong and reproducible SERS spectra of surface-adsorbed analytes. By functionalizing AuNF with pH-responsive reporter 4-mercaptobenzoic acid (MBA), we have developed an accurate pH SERS sensor for the extracellular microenvironment. We cultured HepG2/C3A on the surface of MBA-AuNF and measured an acidic shift in pHe at the cell–fiber interface. Following exposure to staurosporine, an apoptosis-inducing drug, we observed changes in the HepG2/C3A cellular morphology indicative of controlled cell death, and detected an increase in the pHe of HepG2/C3A. These results demonstrate how subtle changes in pHe, induced by the metabolic activity of cells, can be measured with our novel SERS sensor MBA-AuNF. The excellent pH measurement performance of MBA-AuNF provides a unique platform to study extracellular pH on the microscale and will help to deepen our understanding of pHe in disease pathology.
- 5 October 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (41) , 13844-13851
A SERS-Active Electrospun Polymer Mesh for Spatially Localized pH Measurements of the Cellular Microenvironment
Extracellular pH (pHe) is an important chemical factor in many cellular processes and disease pathologies. The routine sampling of pHe in vitro could lead to innovative advances in therapeutics. To this end, we have fabricated a novel gold-coated polymer mesh, which facilitates the real-time measurement of pHe via surface-enhanced Raman scattering (SERS). In this proof of concept study, we apply our SERS sensor to measure metabolically induced changes in the pHe of carcinoma-derived cell line HepG2/C3A. We demonstrate that gold-coated polyurethane electrospun nanofibers (AuNF) have strong and reproducible SERS spectra of surface-adsorbed analytes. By functionalizing AuNF with pH-responsive reporter 4-mercaptobenzoic acid (MBA), we have developed an accurate pH SERS sensor for the extracellular microenvironment. We cultured HepG2/C3A on the surface of MBA-AuNF and measured an acidic shift in pHe at the cell–fiber interface. Following exposure to staurosporine, an apoptosis-inducing drug, we observed changes in the HepG2/C3A cellular morphology indicative of controlled cell death, and detected an increase in the pHe of HepG2/C3A. These results demonstrate how subtle changes in pHe, induced by the metabolic activity of cells, can be measured with our novel SERS sensor MBA-AuNF. The excellent pH measurement performance of MBA-AuNF provides a unique platform to study extracellular pH on the microscale and will help to deepen our understanding of pHe in disease pathology.