Estimation and Removal of spurious echo Artifacts in single-voxel MRS using Sensitivity Encoding
Preprint
Abstract
Purpose: In localized MR spectroscopy, spurious echo artifacts commonly occur when unsuppressed signal outside the volume-of-interest is exicted and refocused. In the spectral domain, these signals often overlap with metabolite resonances and hinder accurate quantification. Since the artifacts orginate from regions separate from the target MRS voxel, this work proposes that sensitivity encoding based on receive coil sensitivity profiles may be used to separate these signal contributions. Methods: Numerical simulations were performed to explore the effect of sensitivity encoded separation for unknown artifact regions. An imaging-based approach was developed to identify regions that may contribute to spurious echo artifacts, and tested for sensitivity-based unfolding of signal contribution on 6 datasets from 3 brain regions. Spectral data reconstructed using the proposed method (‘ERASE’) were compared to standard coil combination. Results: The method was able to fully separate metabolite and artifact signals if regions were known a priori . Mismatch between estimated and actual artifact locations reduced the efficiency of artifact removal. Water suppression imaging (WSI) was able to identify unsuppressed signal remote from the MRS voxel in all cases, and ERASE reconstruction (of up to 8 distinct locations) led to improvements in spectral quality and reduced fitting errors for the major metabolites compared to standard reconstruction, without significant degradation of spectral SNR. Conclusion: The ERASE reconstruction tool was demonstrated to reduce spurious echo artifacts in single voxel MRS. ERASE may be incorporated into standard MRS workflows to improve spectral quality when scanner hardware limitations or other factors result in out-of-voxel signal contamination.Keywords
All Related Versions
- Published version: Magnetic Resonance in Medicine, 86 (5), 2339.
This publication has 22 references indexed in Scilit:
- Short‐echo, single‐shot, full‐intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: Validation in the cerebellum and brainstemMagnetic Resonance in Medicine, 2010
- k‐space analysis of point‐resolved spectroscopy (PRESS) with regard to spurious echoes in in vivo1H MRSNMR in Biomedicine, 2008
- Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulsesMagnetic Resonance Materials in Physics, Biology and Medicine, 2008
- Unaliasing lipid contamination for MR spectroscopic imaging of gliomas at 3T using sensitivity encoding (SENSE)Magnetic Resonance in Medicine, 2006
- Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifactsNMR in Biomedicine, 2004
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Elimination of artifacts in short echo time 1H MR spectroscopy of the frontal lobeMagnetic Resonance in Medicine, 1996
- Topographic distance and watershed linesSignal Processing, 1994
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993
- Proton spectroscopic imaging of human brainJournal of Magnetic Resonance (1969), 1992