Influences of brain tissue poroelastic constants on intracranial pressure (ICP) during constant-rate infusion
Authors:
- 1 December 2013
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 16 (12) , 1330-1343
Abstract
A 3D finite element (FE) model has been developed to study the mean intracranial pressure (ICP) response during constant-rate infusion using linear poroelasticity. Due to the uncertainties in the poroelastic constants for brain tissue, the influence of each of the main parameters on the transient ICP infusion curve was studied. As a prerequisite for transient analysis, steady-state simulations were performed first. The simulated steady-state pressure distribution in the brain tissue for a normal cerebrospinal fluid (CSF) circulation system showed good correlation with experiments from the literature. Furthermore, steady-state ICP closely followed the infusion experiments at different infusion rates. The verified steady-state models then served as a baseline for the subsequent transient models. For transient analysis, the simulated ICP shows a similar tendency to that found in the experiments, however, different values of the poroelastic constants have a significant effect on the infusion curve. The influence of the main poroelastic parameters including the Biot coefficient , Skempton coefficient B, drained Young's modulus E, Poisson's ratio , permeability , CSF absorption conductance and external venous pressure was studied to investigate the influence on the pressure response. It was found that the value of the specific storage term is the dominant factor that influences the infusion curve, and the drained Young's modulus E was identified as the dominant parameter second to . Based on the simulated infusion curves from the FE model, artificial neural network (ANN) was used to find an optimised parameter set that best fit the experimental curve. The infusion curves from both the FE simulation and using ANN confirmed the limitation of linear poroelasticity in modelling the transient constant-rate infusion.Keywords
This publication has 37 references indexed in Scilit:
- Influence of gravity for optimal head positions in the treatment of head injury patientsActa Neurochirurgica, 2011
- The function and structure of the cerebrospinal fluid outflow systemFluids and Barriers of the CNS, 2010
- Voxelized Model of Interstitial Transport in the Rat Spinal Cord Following Direct Infusion Into White MatterJournal of Biomechanical Engineering, 2009
- Normal and Hydrocephalic Brain Dynamics: The Role of Reduced Cerebrospinal Fluid Reabsorption in Ventricular EnlargementAnnals of Biomedical Engineering, 2009
- Analytic solution during an infusion test of the linear unsteady poroelastic equations in a spherically symmetric model of the brainMathematical Medicine and Biology: A Journal of the IMA, 2008
- A model for an inverse power constitutive law for cerebral complianceMathematical Medicine and Biology: A Journal of the IMA, 2008
- Artificial neural network for parameter identifications for an elasto-plastic model of superconducting cable under cyclic loadingComputers & Structures, 2002
- Nerve fibers innervating the cranial and spinal meninges: Morphology of nerve fiber terminals and their structural integrationMicroscopy Research and Technique, 2001
- Effect of Surface Finish on Gear Tooth FrictionJournal of Tribology, 1999
- Bone poroelasticityJournal of Biomechanics, 1999