Abstract
Background: Cryoballoon (CB) ablation has been an established single-shot technique for first-time pulmonary vein isolation (PVI), whereas pulsed field ablation (PFA) is being increasingly adopted in clinical practice. Although both technologies are designed to facilitate efficient PVI, comparative real-world evidence from large cohorts remains limited. Methods: We conducted a retrospective analysis of consecutive patients undergoing index pulmonary vein isolation (PVI) at a high-volume German tertiary referral center between 2021 and 2025. Clinical baseline characteristics, procedural metrics, and acute safety outcomes were collected using a standardized approach and subsequently analyzed. The primary efficacy endpoint was the recurrence of atrial tachyarrhythmia, documented by ECG or Holter monitoring after completion of a prespecified 90-day blanking period. Secondary endpoints included acute procedural efficacy and safety, early atrial tachyarrhythmia recurrence during the blanking period, and the durability of pulmonary vein isolation (PVI), determined by high-density electroanatomical remapping at the time of repeat ablation. Results: A total of 1,961 patients were included in the analysis, of whom 1,369 underwent cryoballoon (CB) ablation and 592 underwent pulsed field ablation (PFA) using a pentaspline catheter. Baseline characteristics were comparable between groups with respect to sex, age, atrial fibrillation (AF) type, left ventricular ejection fraction, history of stroke/transient ischemic attack (TIA), antiarrhythmic drug therapy, and anticoagulation status. Median procedure duration was shorter in the PFA group compared with the CB group (46 [Q1–Q3: 40–55] vs. 75 [60–85] minutes; p<0.001). Acute safety outcomes were similar between groups. Major complications occurred in 0.8% of CB procedures and 0.5% of PFA procedures (p=0.77), while minor complications were observed in 1.2% and 0.4% of procedures, respectively (p=0.091). During a median follow-up of 1,076 days (95% confidence interval [CI] 972–1,243), the incidence of atrial tachyarrhythmia recurrence beyond the 90-day blanking period did not differ significantly between groups (hazard ratio [HR] 1.02, 95% CI 0.804–1.294; p=0.827). Repeat ablation was performed in 204 patients (10.4%), including 169 of 1,369 patients (12.3%) in the CB group and 35 of 592 patients (5.9%) in the PFA group. Among patients undergoing repeat procedures, complete pulmonary vein (PV) isolation at high-density remapping was observed more frequently following PFA than following CB ablation (45.7% vs. 22.5%; p=0.01). Reconnection rates in the right superior and right inferior PVs were lower after PFA compared with CB ablation (14.3% vs. 50.3% and 14.3% vs. 48.5%, respectively; both p<0.001). Conclusion: In this large real-world cohort, both CB and PFA were associated with favorable acute safety profiles and comparable long-term freedom from atrial tachyarrhythmia recurrence. PVI durability differed between treatment modalities, with PFA demonstrating a higher proportion of complete pulmonary vein isolation using high-density remapping compared with CB ablation.