RWRahin Wahedi

Rahin Wahedi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rahin Wahedi has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Real-World Comparison of Cryoballoon and Pulsed Field Ablation for First-Time Pulmonary Vein Isolation

    by Ilaria My, Rahin Wahedi, Jannis Dickow, Tim Harloff, Masih Ruhin, Zeynep Demirtakan, Laura Fischbach, Katharina Massi, Maximilian Maus, Nele Gessler, et al.

    Background: Cryoballoon (CB) ablation has been an established single-shot technique for first-time pulmonary vein isolation (PVI), whereas pulsed field ablation (PFA) is being increasingly adopted in clinical practice. Although both technologies are designed to facilitate efficient PVI, comparative real-world evidence from large cohorts remains limited. Methods: We conducted a retrospective analysis of consecutive patients undergoing index pulmonary vein isolation (PVI) at a high-volume German tertiary referral center between 2021 and 2025. Clinical baseline characteristics, procedural metrics, and acute safety outcomes were collected using a standardized approach and subsequently analyzed. The primary efficacy endpoint was the recurrence of atrial tachyarrhythmia, documented by ECG or Holter monitoring after completion of a prespecified 90-day blanking period. Secondary endpoints included acute procedural efficacy and safety, early atrial tachyarrhythmia recurrence during the blanking period, and the durability of pulmonary vein isolation (PVI), determined by high-density electroanatomical remapping at the time of repeat ablation. Results: A total of 1,961 patients were included in the analysis, of whom 1,369 underwent cryoballoon (CB) ablation and 592 underwent pulsed field ablation (PFA) using a pentaspline catheter. Baseline characteristics were comparable between groups with respect to sex, age, atrial fibrillation (AF) type, left ventricular ejection fraction, history of stroke/transient ischemic attack (TIA), antiarrhythmic drug therapy, and anticoagulation status. Median procedure duration was shorter in the PFA group compared with the CB group (46 [Q1–Q3: 40–55] vs. 75 [60–85] minutes; p<0.001). Acute safety outcomes were similar between groups. Major complications occurred in 0.8% of CB procedures and 0.5% of PFA procedures (p=0.77), while minor complications were observed in 1.2% and 0.4% of procedures, respectively (p=0.091). During a median follow-up of 1,076 days (95% confidence interval [CI] 972–1,243), the incidence of atrial tachyarrhythmia recurrence beyond the 90-day blanking period did not differ significantly between groups (hazard ratio [HR] 1.02, 95% CI 0.804–1.294; p=0.827). Repeat ablation was performed in 204 patients (10.4%), including 169 of 1,369 patients (12.3%) in the CB group and 35 of 592 patients (5.9%) in the PFA group. Among patients undergoing repeat procedures, complete pulmonary vein (PV) isolation at high-density remapping was observed more frequently following PFA than following CB ablation (45.7% vs. 22.5%; p=0.01). Reconnection rates in the right superior and right inferior PVs were lower after PFA compared with CB ablation (14.3% vs. 50.3% and 14.3% vs. 48.5%, respectively; both p<0.001). Conclusion: In this large real-world cohort, both CB and PFA were associated with favorable acute safety profiles and comparable long-term freedom from atrial tachyarrhythmia recurrence. PVI durability differed between treatment modalities, with PFA demonstrating a higher proportion of complete pulmonary vein isolation using high-density remapping compared with CB ablation.

  • Open Access

    Device malfunction following epicardial pulsed field ablation using a focal dual energy ablation catheter in a patient with cardiac resynchronization therapy defibrillator: a case report

    by Rahin Wahedi, Julia Vogler, Stephan Willems, Arian Sultan

    Background: Pulsed field ablation (PFA) is increasingly used, but experience with ventricular, and particularly epicardial, applications in patients with cardiac implantable electronic devices (CIEDs) remains limited. Case summary: A 49-year-old woman with LMNA- and SCN5A-associated cardiomyopathy, mildly reduced left ventricular ejection fraction (45%), and a cardiac resynchronization therapy defibrillator (CRT-D) presented with recurrent ventricular tachycardia (VT) and implantable cardioverter-defibrillator shocks. Previous endocardial VT ablation had revealed no relevant endocardial low-voltage substrate. Repeat ablation was performed using a combined endo–epicardial approach. Epicardial mapping identified extensive low-voltage areas, with the best pace-map match at the basal lateral left ventricle. Ablation was performed using a focal dual-energy catheter with radiofrequency energy up to 40 W and PFA (2400 V). Following epicardial PFA in proximity to the device generator and left ventricular lead, pacing abruptly changed from VVI 30/min to DDD 70/min. Initial attempts at device interrogation failed. After communication was restored, interrogation demonstrated that the CRT-D had reverted to factory settings. The device was successfully reset and reprogrammed. Further PFA near the LV lead or generator was avoided. Sensing, pacing thresholds, and lead impedances were preserved. Discussion: To our knowledge, this is the first report of a clinically relevant transient CIED malfunction temporally associated with epicardial ventricular PFA using a focal single-tip dual-energy ablation catheter. Although no permanent generator or lead dysfunction occurred, this observation highlights the potential for PFA–CIED interactions beyond conventional PFA workflows and across different catheter technologies.

  • Open Access

    Versatility of the novel balloon-in-basket pulsed field ablation catheter: Pulmonary vein isolation and beyond

    by Rahin Wahedi, Zeynep Demirtakan, I. My, Julia Vogler, Mario Jularic, Jannis Dickow, Tim Harloff, Laura Fischbach, Masih Ruhin, Borislav Dinov, et al.

  • Catheter Ablation for Atrial Fibrillation in Octogenarians—Outcome and Impact for Future Same Day Discharge Strategies

    by Rahin Wahedi, Stephan Willems, Mario Jularic, Jens Hartmann, Omar Anwar, Jannis Dickow, Tim Harloff, Philipp Bengel, Peter Wohlmuth, Andreas Metzner, et al.

    Background: Catheter ablation (CA) for atrial fibrillation (AF) in the elderly poses a growing challenge. Outcome data regarding CA in these patients are scarce.Methods: Octogenarians with AF or consecutive atrial tachycardia undergoing index or re‐ablation (pulmonary vein isolation [PVI] and ablation beyond PVI with different energy sources) in a single center, were analyzed. Study endpoints were efficacy as well as procedural safety. Secondary endpoints included periprocedural complications and predictors for prolonged hospital stay.Results: In total, 301 patients (82.1 ± 1.9 years, paroxysmal AF n = 94 [31.2%], CHA2DS2‐VASc‐Score 4.2 ± 1.2) undergoing index ablation (n = 172/301, 57.1% [PVI only n = 156/172, radiofrequency n = 92, cryoballoon n = 59, pulsed‐field ablation n = 5]) and re‐ablation (n = 129/301 [42.9%]) were included. Arrhythmia‐free survival at 1 year was 72.6%. Complication rates were low (groin site n = 2/301 [0.7%], tamponade n = 2/301 [0.7%] and stroke n = 1/301 [0.3%]). However concomitant infections (pneumonia n = 5/301 [1.7%], urinary‐tract‐infections n = 4/301, [1.3%]) and pacemaker‐implantation n = 6/301 (2%) occurred more commonly. Hospital stay after CA was 2.3 ± 2 nights. Predictors for prolonged hospitalization were complications (odds ratio: 3.1), infections (odds ratio: 2.1), female sex (odds ratio: 1.15) and frailty assessed by Barthel index (odds ratio: 1.02).Conclusions: CA for AF in octogenarians shows low procedural complications and reasonable efficacy. However, concomitant infections and pacemaker implantations occur in this cohort. Due to prolonged hospitalization after CA, especially in female and frail octogenarians, same‐day discharge may not be suitable for this specific patient cohort.