Magnetic resonance elastography for estimating in vivo stiffness of the abdominal aorta using cardiac‐gated spin‐echo echo‐planar imaging: a feasibility study
- 6 October 2020
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (1) , e4420
Abstract
Introduction: Magnetic resonance elastography (MRE)‐derived aortic stiffness is a potential biomarker for multiple cardiovascular diseases. Currently, gradient‐recalled echo (GRE) MRE is a widely accepted technique to estimate aortic stiffness. However, multi‐slice GRE MRE requires multiple breath‐holds (BHs), which can be challenging for patients who cannot consistently hold their breath. The aim of this study was to investigate the feasibility of a multi‐slice spin‐echo echo‐planar imaging (SE‐EPI) MRE sequence for quantifying in vivo aortic stiffness using a free‐breathing (FB) protocol and a single‐BH protocol.Method: On Scanner 1, 25 healthy subjects participated in the validation of FB SE‐EPI against FB GRE. On Scanner 2, another 15 healthy subjects were recruited to compare FB SE‐EPI with single‐BH SE‐EPI. Among all volunteers, five participants were studied on both scanners to investigate the inter‐scanner reproducibility of FB SE‐EPI aortic MRE. Bland‐Altman analysis, Lin's concordance correlation coefficient (LCCC) and coefficient of variation (COV) were evaluated. The phase‐difference signal‐to‐noise ratios (PD SNR) were compared.Results: Aortic MRE using FB SE‐EPI and FB GRE yielded similar stiffnesses (paired t‐test, P = 0.19), with LCCC = 0.97. The FB SE‐EPI measurements were reproducible (intra‐scanner LCCC = 0.96) and highly repeatable (LCCC = 0.99). The FB SE‐EPI MRE was also reproducible across different scanners (inter‐scanner LCCC = 0.96). Single‐BH SE‐EPI scans yielded similar stiffness to FB SE‐EPI scans (LCCC = 0.99) and demonstrated a low COV of 2.67% across five repeated measurements.Conclusion: Multi‐slice SE‐EPI aortic MRE using an FB protocol or a single‐BH protocol is reproducible and repeatable with advantage over multi‐slice FB GRE in reducing acquisition time. Additionally, FB SE‐EPI MRE provides a potential alternative to BH scans for patients who have challenges in holding their breath.Keywords
Funding Information
- National Institutes of Health (NIH‐R01HL124096)
This publication has 57 references indexed in Scilit:
- Advances and Future Direction of Magnetic Resonance ElastographyTopics in Magnetic Resonance Imaging, 2018
- Quantification of breast stiffness using MR elastography at 3 Tesla with a soft sternal driver: A reproducibility studyJournal of Magnetic Resonance Imaging, 2016
- Magnetic resonance elastography of liver: Technique, analysis, and clinical applicationsJournal of Magnetic Resonance Imaging, 2013
- Decreased brain stiffness in Alzheimer's disease determined by magnetic resonance elastographyJournal of Magnetic Resonance Imaging, 2011
- Magnetic resonance elastography: A reviewClinical Anatomy, 2010
- MR-elastography reveals degradation of tissue integrity in multiple sclerosisNeuroImage, 2010
- Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastographyNMR in Biomedicine, 2007
- Magnetic resonance elastography: Non-invasive mapping of tissue elasticityMedical Image Analysis, 2001
- High-resolution tensor MR elastography for breast tumour detectionPhysics in Medicine & Biology, 2000
- Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain WavesScience, 1995