Arunark Kolipaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arunark Kolipaka has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
Xiaokui Mo
Departments of Biomedical Informatics and Center for Biostatistics
12 shared publicationsBrian Raterman
Department of Radiology The Ohio State University Wexner Medical Center Columbus Ohio USA
10 shared publicationsRichard D. White
Department of Radiology The Ohio State University Wexner Medical Center Columbus Ohio USA
7 shared publications- Richard D. White
Division of Cardiothoracic Imaging, Department of Radiology, Mayo Clinic, Jacksonville, USA
6 shared publications Prateek Kalra
Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
5 shared publicationsHuiming Dong
Department of Biomedical Engineering, The Ohio State University, Columbus, OH
4 shared publications
Latest Publications
- Open Access
Deep Learning-Driven Inversion Framework for Shear Modulus Estimation in Magnetic Resonance Elastography (DIME)
The Multimodal Direct Inversion (MMDI) algorithm is widely used in Magnetic Resonance Elastography (MRE) to estimate tissue shear stiffness. However, MMDI relies on the Helmholtz equation, which assumes wave propagation in a uniform, homogeneous, and infinite medium. Furthermore, the use of the Laplacian operator makes MMDI highly sensitive to noise, which compromises the accuracy and reliability of stiffness estimates. In this study, we propose the Deep-Learning driven Inversion Framework for Shear Modulus Estimation in MRE (DIME), aimed at enhancing the robustness of inversion. DIME is trained on the displacement fields-stiffness maps pair generated through Finite Element Modelling (FEM) simulations. To capture local wave behavior and improve robustness to global image variations, DIME is trained on small image patches. We first validated DIME using homogeneous and heterogeneous datasets simulated with FEM, where DIME produced stiffness maps with low inter-pixel variability, accurate boundary delineation, and higher correlation with ground truth (GT) compared to MMDI. Next, DIME was evaluated in a realistic anatomy-informed simulated liver dataset with known GT and compared directly to MMDI. DIME reproduced ground-truth stiffness patterns with high fidelity (r = 0.99, R^2 = 0.98), while MMDI showed greater underestimation. After validating DIME on synthetic data, we tested the model in in vivo liver MRE data from eight healthy and seven fibrotic subjects. DIME preserved physiologically consistent stiffness patterns and closely matched MMDI, which showed directional bias. Overall, DIME showed higher correlation with ground truth and visually similar stiffness patterns, whereas MMDI displayed a larger bias that can potentially be attributed to directional filtering. These preliminary results highlight the feasibility of DIME for clinical applications in MRE.
Open AccessDeep Learning-Driven Inversion Framework for Shear Modulus Estimation in Magnetic Resonance Elastography (DIME)
The Multimodal Direct Inversion (MMDI) algorithm is widely used in Magnetic Resonance Elastography (MRE) to estimate tissue shear stiffness. However, MMDI relies on the Helmholtz equation, which assumes wave propagation in a uniform, homogeneous, and infinite medium. Furthermore, the use of the Laplacian operator makes MMDI highly sensitive to noise, which compromises the accuracy and reliability of stiffness estimates. In this study, we propose the Deep-Learning driven Inversion Framework for Shear Modulus Estimation in MRE (DIME), aimed at enhancing the robustness of inversion. DIME is trained on the displacement fields-stiffness maps pair generated through Finite Element Modelling (FEM) simulations. To capture local wave behavior and improve robustness to global image variations, DIME is trained on small image patches. We first validated DIME using homogeneous and heterogeneous datasets simulated with FEM, where DIME produced stiffness maps with low inter-pixel variability, accurate boundary delineation, and higher correlation with ground truth (GT) compared to MMDI. Next, DIME was evaluated in a realistic anatomy-informed simulated liver dataset with known GT and compared directly to MMDI. DIME reproduced ground-truth stiffness patterns with high fidelity (r = 0.99, R^2 = 0.98), while MMDI showed greater underestimation. After validating DIME on synthetic data, we tested the model in in vivo liver MRE data from eight healthy and seven fibrotic subjects. DIME preserved physiologically consistent stiffness patterns and closely matched MMDI, which showed directional bias. Overall, DIME showed higher correlation with ground truth and visually similar stiffness patterns, whereas MMDI displayed a larger bias that can potentially be attributed to directional filtering. These preliminary results highlight the feasibility of DIME for clinical applications in MRE.
- Open Access
- 15 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107229
Nano-mechanical mapping of human and porcine abdominal aortic aneurysm
- 15 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107229
Open AccessNano-mechanical mapping of human and porcine abdominal aortic aneurysm
- Open Access
- 24 June 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Tumor biomechanical stiffness by magnetic resonance elastography predicts surgical outcomes and identifies biomarkers in vestibular schwannoma and meningioma
Variations in the biomechanical stiffness of brain tumors can not only influence the difficulty of surgical resection but also impact postoperative outcomes. In a prospective, single-blinded study, we utilize pre-operative magnetic resonance elastography (MRE) to predict the stiffness of intracranial tumors intraoperatively and assess the impact of increased tumor stiffness on clinical outcomes following microsurgical resection of vestibular schwannomas (VS) and meningiomas. MRE measurements significantly correlated with intraoperative tumor stiffness and baseline hearing status of VS patients. Additionally, MRE stiffness was elevated in patients that underwent sub-total tumor resection compared to gross total resection and those with worse postoperative facial nerve function. Furthermore, we identify tumor microenvironment biomarkers of increased stiffness, including αSMA + myogenic fibroblasts, CD163 + macrophages, and HABP (hyaluronic acid binding protein). In a human VS cell line, a dose-dependent upregulation of HAS1-3, enzymes responsible for hyaluronan synthesis, was observed following stimulation with TNFα, a proinflammatory cytokine present in VS. Taken together, MRE is an accurate, non-invasive predictor of tumor stiffness in VS and meningiomas. VS with increased stiffness portends worse preoperative hearing and poorer postoperative outcomes. Moreover, inflammation-mediated hyaluronan deposition may lead to increased stiffness.
- 24 June 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessTumor biomechanical stiffness by magnetic resonance elastography predicts surgical outcomes and identifies biomarkers in vestibular schwannoma and meningioma
Variations in the biomechanical stiffness of brain tumors can not only influence the difficulty of surgical resection but also impact postoperative outcomes. In a prospective, single-blinded study, we utilize pre-operative magnetic resonance elastography (MRE) to predict the stiffness of intracranial tumors intraoperatively and assess the impact of increased tumor stiffness on clinical outcomes following microsurgical resection of vestibular schwannomas (VS) and meningiomas. MRE measurements significantly correlated with intraoperative tumor stiffness and baseline hearing status of VS patients. Additionally, MRE stiffness was elevated in patients that underwent sub-total tumor resection compared to gross total resection and those with worse postoperative facial nerve function. Furthermore, we identify tumor microenvironment biomarkers of increased stiffness, including αSMA + myogenic fibroblasts, CD163 + macrophages, and HABP (hyaluronic acid binding protein). In a human VS cell line, a dose-dependent upregulation of HAS1-3, enzymes responsible for hyaluronan synthesis, was observed following stimulation with TNFα, a proinflammatory cytokine present in VS. Taken together, MRE is an accurate, non-invasive predictor of tumor stiffness in VS and meningiomas. VS with increased stiffness portends worse preoperative hearing and poorer postoperative outcomes. Moreover, inflammation-mediated hyaluronan deposition may lead to increased stiffness.
- 25 October 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (4) , 299-306
Magnetic Resonance Elastography (MRE) of Bleomycin-Induced Pulmonary Fibrosis in an Animal Model
Background: Idiopathic pulmonary fibrosis is responsible for 40,000 deaths annually in the United States. A hallmark of idiopathic pulmonary fibrosis is elevated collagen deposition, which alters lung stiffness. Clinically relevant ways to measure changes in lung stiffness during pulmonary fibrosis are not available, and new noninvasive imaging methods are needed to measure changes in lung mechanical properties. Objectives: Magnetic resonance elastography (MRE) is an in vivo magnetic resonance imaging technique proven to detect changes in shear stiffness in different organs. This study used MRE, histology, and bronchoalveolar lavage (BAL) to study changes in the mechanical and structural properties of the lungs after bleomycin-induced pulmonary fibrosis in pigs. Materials and Methods: Pulmonary fibrosis was induced in 9 Yorkshire pigs by intratracheal instillation of 2 doses of bleomycin into the right lung only. Magnetic resonance elastography scans were performed at baseline and week 4 and week 8 postsurgery in a 1.5 T magnetic resonance imaging scanner using a spin-echo echo planar imaging sequence to measure changes in lung shear stiffness. At the time of each scan, a BAL was performed. After the final scan, whole lung tissue was removed and analyzed for histological changes. Results: Mean MRE-derived stiffness measurements at baseline, week 4, and week 8 for the control (left) lungs were 1.02 ± 0.27 kPa, 0.86 ± 0.29 kPa, and 0.68 ± 0.20 kPa, respectively. The ratio of the shear stiffness in the injured (right) lung to the uninjured control (left) lung at baseline, week 4, and week 8 was 0.98 ± 0.23, 1.52 ± 0.41, and 1.64 ± 0.40, respectively. High-dose animals showed increased protein in BAL fluid, elevated inflammation observed by the presence of patchy filtrates, and enhanced collagen and α-smooth muscle actin staining on histological sections. Low-dose animals and the control (left) lungs of high-dose animals did not show significant histopathological changes. Conclusion: This study demonstrated that MRE can be used to detect changes in lung stiffness in pigs after bleomycin challenge.
- 25 October 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (4) , 299-306
Magnetic Resonance Elastography (MRE) of Bleomycin-Induced Pulmonary Fibrosis in an Animal Model
Background: Idiopathic pulmonary fibrosis is responsible for 40,000 deaths annually in the United States. A hallmark of idiopathic pulmonary fibrosis is elevated collagen deposition, which alters lung stiffness. Clinically relevant ways to measure changes in lung stiffness during pulmonary fibrosis are not available, and new noninvasive imaging methods are needed to measure changes in lung mechanical properties. Objectives: Magnetic resonance elastography (MRE) is an in vivo magnetic resonance imaging technique proven to detect changes in shear stiffness in different organs. This study used MRE, histology, and bronchoalveolar lavage (BAL) to study changes in the mechanical and structural properties of the lungs after bleomycin-induced pulmonary fibrosis in pigs. Materials and Methods: Pulmonary fibrosis was induced in 9 Yorkshire pigs by intratracheal instillation of 2 doses of bleomycin into the right lung only. Magnetic resonance elastography scans were performed at baseline and week 4 and week 8 postsurgery in a 1.5 T magnetic resonance imaging scanner using a spin-echo echo planar imaging sequence to measure changes in lung shear stiffness. At the time of each scan, a BAL was performed. After the final scan, whole lung tissue was removed and analyzed for histological changes. Results: Mean MRE-derived stiffness measurements at baseline, week 4, and week 8 for the control (left) lungs were 1.02 ± 0.27 kPa, 0.86 ± 0.29 kPa, and 0.68 ± 0.20 kPa, respectively. The ratio of the shear stiffness in the injured (right) lung to the uninjured control (left) lung at baseline, week 4, and week 8 was 0.98 ± 0.23, 1.52 ± 0.41, and 1.64 ± 0.40, respectively. High-dose animals showed increased protein in BAL fluid, elevated inflammation observed by the presence of patchy filtrates, and enhanced collagen and α-smooth muscle actin staining on histological sections. Low-dose animals and the control (left) lungs of high-dose animals did not show significant histopathological changes. Conclusion: This study demonstrated that MRE can be used to detect changes in lung stiffness in pigs after bleomycin challenge.
- 1 September 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 304 (3) , 721-729
MR Elastography of Abdominal Aortic Aneurysms: Relationship to Aneurysm Events
Abdominal aortic aneurysm stiffness and stiffness ratio at MR elastography were lower in participants with later aneurysm rupture, repair, or expansion versus participants without such events. Background Abdominal aortic aneurysm (AAA) diameter remains the standard clinical parameter to predict growth and rupture. Studies suggest that using solely AAA diameter for risk stratification is ...
- 1 September 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 304 (3) , 721-729
MR Elastography of Abdominal Aortic Aneurysms: Relationship to Aneurysm Events
Abdominal aortic aneurysm stiffness and stiffness ratio at MR elastography were lower in participants with later aneurysm rupture, repair, or expansion versus participants without such events. Background Abdominal aortic aneurysm (AAA) diameter remains the standard clinical parameter to predict growth and rupture. Studies suggest that using solely AAA diameter for risk stratification is ...
- 1 November 2021
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 29 (4) , 617-630
Magnetic Resonance Elastography of the Brain
- 1 November 2021
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 29 (4) , 617-630
Magnetic Resonance Elastography of the Brain
- 31 August 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (1) , 236-248
Free‐breathing MR elastography of the lungs: An in vivo study
Purpose: Lung stiffness alters with many diseases; therefore, several MR elastography (MRE) studies were performed earlier to investigate the stiffness of the right lung during breathhold at residual volume and total lung capacity. The aims of this study were 1) to estimate shear stiffness of the lungs using MRE under free breathing and demonstrate the measurements’ repeatability and reproducibility, and 2) to compare lung stiffness under free breathing to breathhold and as a function of age and gender.Methods: Twenty‐five healthy volunteers were scanned on a 1.5 Tesla MRI scanner. Spin‐echo dual‐density spiral and a spin‐echo EPI MRE sequences were used to measure shear stiffness of the lungs during free breathing and breathhold at midpoint of tidal volume, respectively. Concordance correlation coefficient and Bland‐Altman analyses were performed to determine the repeatability and reproducibility of the spin‐echo dual‐density spiral–derived shear stiffness. Repeated measures analyses of variances were used to investigate differences in shear stiffness between spin‐echo dual‐density spiral and spin‐echo EPI, right and left lungs, males and females, and different age groups.Results: Free‐breathing MRE sequence was highly repeatable and reproducible (concordance correlation coefficient > 0.86 for both lungs). Lung stiffness was significantly lower in breathhold than in free breathing (P < .001), which can be attributed to potential stress relaxation of lung parenchyma or breathhold inconsistencies. However, there was no significant difference between different age groups (P = .08). The left lung showed slightly higher stiffness values than the right lung (P = .14). There is no significant difference in lung stiffness between genders.Conclusion: This study demonstrated the feasibility of free‐breathing lung MRE with excellent repeatability and reproducibility. Stiffness changes with age and during the respiratory cycle. However, gender does not influence lungs stiffness.
- 31 August 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (1) , 236-248
Free‐breathing MR elastography of the lungs: An in vivo study
Purpose: Lung stiffness alters with many diseases; therefore, several MR elastography (MRE) studies were performed earlier to investigate the stiffness of the right lung during breathhold at residual volume and total lung capacity. The aims of this study were 1) to estimate shear stiffness of the lungs using MRE under free breathing and demonstrate the measurements’ repeatability and reproducibility, and 2) to compare lung stiffness under free breathing to breathhold and as a function of age and gender.Methods: Twenty‐five healthy volunteers were scanned on a 1.5 Tesla MRI scanner. Spin‐echo dual‐density spiral and a spin‐echo EPI MRE sequences were used to measure shear stiffness of the lungs during free breathing and breathhold at midpoint of tidal volume, respectively. Concordance correlation coefficient and Bland‐Altman analyses were performed to determine the repeatability and reproducibility of the spin‐echo dual‐density spiral–derived shear stiffness. Repeated measures analyses of variances were used to investigate differences in shear stiffness between spin‐echo dual‐density spiral and spin‐echo EPI, right and left lungs, males and females, and different age groups.Results: Free‐breathing MRE sequence was highly repeatable and reproducible (concordance correlation coefficient > 0.86 for both lungs). Lung stiffness was significantly lower in breathhold than in free breathing (P < .001), which can be attributed to potential stress relaxation of lung parenchyma or breathhold inconsistencies. However, there was no significant difference between different age groups (P = .08). The left lung showed slightly higher stiffness values than the right lung (P = .14). There is no significant difference in lung stiffness between genders.Conclusion: This study demonstrated the feasibility of free‐breathing lung MRE with excellent repeatability and reproducibility. Stiffness changes with age and during the respiratory cycle. However, gender does not influence lungs stiffness.
- 6 October 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (1) , e4420
Magnetic resonance elastography for estimating in vivo stiffness of the abdominal aorta using cardiac‐gated spin‐echo echo‐planar imaging: a feasibility study
Introduction: Magnetic resonance elastography (MRE)‐derived aortic stiffness is a potential biomarker for multiple cardiovascular diseases. Currently, gradient‐recalled echo (GRE) MRE is a widely accepted technique to estimate aortic stiffness. However, multi‐slice GRE MRE requires multiple breath‐holds (BHs), which can be challenging for patients who cannot consistently hold their breath. The aim of this study was to investigate the feasibility of a multi‐slice spin‐echo echo‐planar imaging (SE‐EPI) MRE sequence for quantifying in vivo aortic stiffness using a free‐breathing (FB) protocol and a single‐BH protocol.Method: On Scanner 1, 25 healthy subjects participated in the validation of FB SE‐EPI against FB GRE. On Scanner 2, another 15 healthy subjects were recruited to compare FB SE‐EPI with single‐BH SE‐EPI. Among all volunteers, five participants were studied on both scanners to investigate the inter‐scanner reproducibility of FB SE‐EPI aortic MRE. Bland‐Altman analysis, Lin's concordance correlation coefficient (LCCC) and coefficient of variation (COV) were evaluated. The phase‐difference signal‐to‐noise ratios (PD SNR) were compared.Results: Aortic MRE using FB SE‐EPI and FB GRE yielded similar stiffnesses (paired t‐test, P = 0.19), with LCCC = 0.97. The FB SE‐EPI measurements were reproducible (intra‐scanner LCCC = 0.96) and highly repeatable (LCCC = 0.99). The FB SE‐EPI MRE was also reproducible across different scanners (inter‐scanner LCCC = 0.96). Single‐BH SE‐EPI scans yielded similar stiffness to FB SE‐EPI scans (LCCC = 0.99) and demonstrated a low COV of 2.67% across five repeated measurements.Conclusion: Multi‐slice SE‐EPI aortic MRE using an FB protocol or a single‐BH protocol is reproducible and repeatable with advantage over multi‐slice FB GRE in reducing acquisition time. Additionally, FB SE‐EPI MRE provides a potential alternative to BH scans for patients who have challenges in holding their breath.
- 6 October 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (1) , e4420
Magnetic resonance elastography for estimating in vivo stiffness of the abdominal aorta using cardiac‐gated spin‐echo echo‐planar imaging: a feasibility study
Introduction: Magnetic resonance elastography (MRE)‐derived aortic stiffness is a potential biomarker for multiple cardiovascular diseases. Currently, gradient‐recalled echo (GRE) MRE is a widely accepted technique to estimate aortic stiffness. However, multi‐slice GRE MRE requires multiple breath‐holds (BHs), which can be challenging for patients who cannot consistently hold their breath. The aim of this study was to investigate the feasibility of a multi‐slice spin‐echo echo‐planar imaging (SE‐EPI) MRE sequence for quantifying in vivo aortic stiffness using a free‐breathing (FB) protocol and a single‐BH protocol.Method: On Scanner 1, 25 healthy subjects participated in the validation of FB SE‐EPI against FB GRE. On Scanner 2, another 15 healthy subjects were recruited to compare FB SE‐EPI with single‐BH SE‐EPI. Among all volunteers, five participants were studied on both scanners to investigate the inter‐scanner reproducibility of FB SE‐EPI aortic MRE. Bland‐Altman analysis, Lin's concordance correlation coefficient (LCCC) and coefficient of variation (COV) were evaluated. The phase‐difference signal‐to‐noise ratios (PD SNR) were compared.Results: Aortic MRE using FB SE‐EPI and FB GRE yielded similar stiffnesses (paired t‐test, P = 0.19), with LCCC = 0.97. The FB SE‐EPI measurements were reproducible (intra‐scanner LCCC = 0.96) and highly repeatable (LCCC = 0.99). The FB SE‐EPI MRE was also reproducible across different scanners (inter‐scanner LCCC = 0.96). Single‐BH SE‐EPI scans yielded similar stiffness to FB SE‐EPI scans (LCCC = 0.99) and demonstrated a low COV of 2.67% across five repeated measurements.Conclusion: Multi‐slice SE‐EPI aortic MRE using an FB protocol or a single‐BH protocol is reproducible and repeatable with advantage over multi‐slice FB GRE in reducing acquisition time. Additionally, FB SE‐EPI MRE provides a potential alternative to BH scans for patients who have challenges in holding their breath.
- 1 July 2020
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 55 (7) , 463-472
In Vivo Aortic Magnetic Resonance Elastography in Abdominal Aortic Aneurysm
Objectives: Using maximum diameter of an abdominal aortic aneurysm (AAA) alone for management can lead to delayed interventions or unnecessary urgent repairs. Abdominal aortic aneurysm stiffness plays an important role in its expansion and rupture. In vivo aortic magnetic resonance elastography (MRE) was developed to spatially measure AAA stiffness in previous pilot studies and has not been thoroughly validated and evaluated for its potential clinical value. This study aims to evaluate noninvasive in vivo aortic MRE-derived stiffness in an AAA porcine model and investigate the relationships between MRE-derived AAA stiffness and (1) histopathology, (2) uniaxial tensile test, and (3) burst testing for assessing MRE's potential in evaluating AAA rupture risk. Materials and Methods: Abdominal aortic aneurysm was induced in 31 Yorkshire pigs (n = 226 stiffness measurements). Animals were randomly divided into 3 cohorts: 2-week, 4-week, and 4-week-burst. Aortic MRE was sequentially performed. Histopathologic analyses were performed to quantify elastin, collagen, and mineral densities. Uniaxial tensile test and burst testing were conducted to measure peak stress and burst pressure for assessing the ultimate wall strength. Results: Magnetic resonance elastography–derived AAA stiffness was significantly higher than the normal aorta. Significant reduction in elastin and collagen densities as well as increased mineralization was observed in AAAs. Uniaxial tensile test and burst testing revealed reduced ultimate wall strength. Magnetic resonance elastography–derived aortic stiffness correlated to elastin density (ρ = −0.68; P < 0.0001; n = 60) and mineralization (ρ = 0.59; P < 0.0001; n = 60). Inverse correlations were observed between aortic stiffness and peak stress (ρ = −0.32; P = 0.0495; n = 38) as well as burst pressure (ρ = −0.55; P = 0.0116; n = 20). Conclusions: Noninvasive in vivo aortic MRE successfully detected aortic wall stiffening, confirming the extracellular matrix remodeling observed in the histopathologic analyses. These mural changes diminished wall strength. Inverse correlation between MRE-derived aortic stiffness and aortic wall strength suggests that MRE-derived stiffness can be a potential biomarker for clinically assessing AAA wall status and rupture potential.
- 1 July 2020
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 55 (7) , 463-472
In Vivo Aortic Magnetic Resonance Elastography in Abdominal Aortic Aneurysm
Objectives: Using maximum diameter of an abdominal aortic aneurysm (AAA) alone for management can lead to delayed interventions or unnecessary urgent repairs. Abdominal aortic aneurysm stiffness plays an important role in its expansion and rupture. In vivo aortic magnetic resonance elastography (MRE) was developed to spatially measure AAA stiffness in previous pilot studies and has not been thoroughly validated and evaluated for its potential clinical value. This study aims to evaluate noninvasive in vivo aortic MRE-derived stiffness in an AAA porcine model and investigate the relationships between MRE-derived AAA stiffness and (1) histopathology, (2) uniaxial tensile test, and (3) burst testing for assessing MRE's potential in evaluating AAA rupture risk. Materials and Methods: Abdominal aortic aneurysm was induced in 31 Yorkshire pigs (n = 226 stiffness measurements). Animals were randomly divided into 3 cohorts: 2-week, 4-week, and 4-week-burst. Aortic MRE was sequentially performed. Histopathologic analyses were performed to quantify elastin, collagen, and mineral densities. Uniaxial tensile test and burst testing were conducted to measure peak stress and burst pressure for assessing the ultimate wall strength. Results: Magnetic resonance elastography–derived AAA stiffness was significantly higher than the normal aorta. Significant reduction in elastin and collagen densities as well as increased mineralization was observed in AAAs. Uniaxial tensile test and burst testing revealed reduced ultimate wall strength. Magnetic resonance elastography–derived aortic stiffness correlated to elastin density (ρ = −0.68; P < 0.0001; n = 60) and mineralization (ρ = 0.59; P < 0.0001; n = 60). Inverse correlations were observed between aortic stiffness and peak stress (ρ = −0.32; P = 0.0495; n = 38) as well as burst pressure (ρ = −0.55; P = 0.0116; n = 20). Conclusions: Noninvasive in vivo aortic MRE successfully detected aortic wall stiffening, confirming the extracellular matrix remodeling observed in the histopathologic analyses. These mural changes diminished wall strength. Inverse correlation between MRE-derived aortic stiffness and aortic wall strength suggests that MRE-derived stiffness can be a potential biomarker for clinically assessing AAA wall status and rupture potential.
- Open Access
- 23 January 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (4) , e4252
Simultaneous multislice rapid magnetic resonance elastography of the liver
To design and validate a rapid Simultaneous Multi‐slice (SMS) Magnetic Resonance Elastography technique (MRE), which combines SMS acquisition, in‐plane undersampling and an existing rapid Magnetic Resonance Elastography (MREr) scheme to allow accelerated data acquisition in healthy volunteers and comparison against MREr. SMS‐MREr sequence was developed by incorporating SMS acquisition scheme into an existing MREr sequence that accelerates MRE acquisition by acquiring data during opposite phases of mechanical vibrations. The MREr sequence accelerated MRE acquisition by acquiring data during opposite phases of mechanical vibrations. Liver MRE was performed on 23 healthy subjects using MREr and SMS‐MREr sequences, and mean stiffness values were obtained for manually drawn regions of interest. Linear correlation and agreement between MREr‐ and SMS‐MREr‐based stiffness values were investigated. SMS‐MREr reduced the scan time by half relative to MREr, and allowed acquisition of four‐slice MRE data in a single 17‐second breath‐hold. Visual comparison suggested agreement between MREr and SMS‐MREr elastograms. A Pearson's correlation of 0.93 was observed between stiffness values derived from MREr and SMS‐MREr. Bland–Altman analysis demonstrated good agreement, with −0.08 kPa mean bias and narrow limits of agreement (95% CI: 0.23 to −0.39 kPa) between stiffness values obtained using MREr and SMS‐MREr. SMS can be combined with other fast MRE approaches to achieve further acceleration. This pushes the limit on the acceleration that can be achieved in MRE acquisition, and makes it possible to conduct liver MRE exams in a single breath‐hold.
- 23 January 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (4) , e4252
Open AccessSimultaneous multislice rapid magnetic resonance elastography of the liver
To design and validate a rapid Simultaneous Multi‐slice (SMS) Magnetic Resonance Elastography technique (MRE), which combines SMS acquisition, in‐plane undersampling and an existing rapid Magnetic Resonance Elastography (MREr) scheme to allow accelerated data acquisition in healthy volunteers and comparison against MREr. SMS‐MREr sequence was developed by incorporating SMS acquisition scheme into an existing MREr sequence that accelerates MRE acquisition by acquiring data during opposite phases of mechanical vibrations. The MREr sequence accelerated MRE acquisition by acquiring data during opposite phases of mechanical vibrations. Liver MRE was performed on 23 healthy subjects using MREr and SMS‐MREr sequences, and mean stiffness values were obtained for manually drawn regions of interest. Linear correlation and agreement between MREr‐ and SMS‐MREr‐based stiffness values were investigated. SMS‐MREr reduced the scan time by half relative to MREr, and allowed acquisition of four‐slice MRE data in a single 17‐second breath‐hold. Visual comparison suggested agreement between MREr and SMS‐MREr elastograms. A Pearson's correlation of 0.93 was observed between stiffness values derived from MREr and SMS‐MREr. Bland–Altman analysis demonstrated good agreement, with −0.08 kPa mean bias and narrow limits of agreement (95% CI: 0.23 to −0.39 kPa) between stiffness values obtained using MREr and SMS‐MREr. SMS can be combined with other fast MRE approaches to achieve further acceleration. This pushes the limit on the acceleration that can be achieved in MRE acquisition, and makes it possible to conduct liver MRE exams in a single breath‐hold.