The Effect of Optic Disc Center Displacement on Retinal Nerve Fiber Layer Measurement Determined by Spectral Domain Optical Coherence Tomography
Open Access
- 26 October 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (10) , e0165538
Abstract
To investigate the effect of optic disc center displacement on retinal nerve fiber layer (RNFL) measurement determined by spectral domain optical coherence tomography (SD-OCT). The optic disc center was manipulated at 1-pixel intervals in horizontal, vertical, and diagonal directions. According to the manipulated optic disc center location, the RNFL thickness data were resampled: (1) at a 3.46-mm diameter circle; and (2) between a 2.5-mm diameter circle and 5.4-mm square. Error was calculated between the original and resampled RNFL measurements. The tolerable error threshold of the optic disc center displacement was determined by considering test-retest variability of SD-OCT. The unreliable zone was defined as an area with 10% or more variability. The maximum tolerable error thresholds of optic disc center displacement on the RNFL thickness map were distributed from 0.042 to 0.09 mm in 8 directions. The threshold shape was vertically elongated. Clinically important unreliable zones were located: (1) at superior and inferior region in the vertical displacement; (2) at inferotemporal region in the horizontal displacement, and (3) at superotemporal or inferotemporal region in the diagonal displacement. The unreliable zone pattern and threshold limit varied according to the direction of optic disc displacement. Optic disc center displacement had a considerable impact on whole RNFL thickness measurements. Understanding the effect of optic disc center displacement could contribute to reliable RNFL measurements.Keywords
This publication has 18 references indexed in Scilit:
- Reproducibility of Spectral-Domain Optical Coherence Tomography RNFL Map for Glaucomatous and Fellow Normal Eyes in Unilateral GlaucomaJournal of Glaucoma, 2015
- Glaucoma Diagnostic Capabilities of Optic Nerve Head Parameters as Determined by Cirrus HD Optical Coherence TomographyJournal of Glaucoma, 2012
- Errors in neuroretinal rim measurement by Cirrus high-definition optical coherence tomography in myopic eyesBritish Journal of Ophthalmology, 2012
- Determinants of Quantitative Optic Nerve Measurements Using Spectral Domain Optical Coherence Tomography in a Population-Based Sample of Non-glaucomatous SubjectsInvestigative Ophthalmology & Visual Science, 2011
- Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence TomographyOphthalmology, 2009
- Retinal nerve fibre layer thickness measurement reproducibility improved with spectral domain optical coherence tomographyBritish Journal of Ophthalmology, 2009
- Effects of scan circle displacement in optical coherence tomography retinal nerve fibre layer thickness measurement: a RNFL modelling studyEye, 2008
- Effect of Improper Scan Alignment on Retinal Nerve Fiber Layer Thickness Measurements Using Stratus Optical Coherence TomographJournal of Glaucoma, 2008
- Optical Coherence Tomography Scan Circle Location and Mean Retinal Nerve Fiber Layer Measurement VariabilityInvestigative Ophthalmology & Visual Science, 2008
- Reproducibility of Peripapillary Retinal Nerve Fiber Thickness Measurements with Stratus OCT in Glaucomatous EyesOphthalmology, 2008